ISO 20456:2017
Current
The latest, up-to-date edition.
Measurement of fluid flow in closed conduits — Guidance for the use of electromagnetic flowmeters for conductive liquids
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
French, English
15-09-2017
ISO 20456:2017 applies to industrial electromagnetic flowmeters used for the measurement of flowrate of a conductive liquid in a closed conduit running full. It covers flowmeter types utilizing both alternating current (AC) and pulsed direct current (DC) circuits to drive the field coils and meters running from a mains power supply and those operating from batteries or other sources of power.
ISO 20456:2017 is not applicable to insertion-type flowmeters or electromagnetic flowmeters designed to work in open channels or pipes running partially full, nor does it apply to the measurement of magnetically permeable slurries or liquid metal applications.
ISO 20456:2017 does not specify safety requirements in relation to hazardous environmental usage of the flowmeter.
DevelopmentNote |
Supersedes ISO 6817, ISO 9104, ISO 13359 and ISO/DIS 20456. (09/2017)
|
DocumentType |
Standard
|
Pages |
33
|
PublisherName |
International Organization for Standardization
|
Status |
Current
|
Supersedes |
Standards | Relationship |
SN EN ISO 20456:2020 | Identical |
NEN-EN-ISO 20456:2019 | Identical |
NEN ISO 20456 : 2017 | Identical |
SS-EN ISO 20456:2019 | Identical |
BS EN ISO 20456:2019 | Identical |
I.S. EN ISO 20456:2019 | Identical |
DIN EN ISO 20456:2020-09 | Identical |
EN ISO 20456:2019 | Identical |
NS-EN ISO 20456:2019 | Identical |
UNI EN ISO 20456:2020 | Identical |
PN-EN ISO 20456:2020-03 | Identical |
ÖNORM EN ISO 20456: 2020 04 15 | Identical |
UNE-EN ISO 20456:2021 | Identical |
OIML R 49-3 : 2013 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 3: TEST REPORT FORMAT |
OIML R 117-2 : 2014 | DYNAMIC MEASURING SYSTEMS FOR LIQUIDS OTHER THAN WATER - PART 2: METROLOGICAL CONTROLS AND PERFORMANCE TESTS |
OIML R 75-3 : 2006 | HEAT METERS - PART 3: TEST REPORT FORMAT |
IEC 60381-1:1982 | Analogue signals for process control systems. Part 1: Direct current signals |
EN 14154-1:2005+A2:2011 | Water meters - Part 1: General requirements |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
ISO 5168:2005 | Measurement of fluid flow — Procedures for the evaluation of uncertainties |
ISO 4064-4:2014 | Water meters for cold potable water and hot water — Part 4: Non-metrological requirements not covered in ISO 4064-1 |
ISO/IEC Guide 98-1:2009 | Uncertainty of measurement — Part 1: Introduction to the expression of uncertainty in measurement |
ISO 7066-1:1989 | Assessment of uncertainty in the calibration and use of flow measurement devices Part 1: Linear calibration relationships |
ISO 4064-5:2014 | Water meters for cold potable water and hot water — Part 5: Installation requirements |
ISO 4064-3:2014 | Water meters for cold potable water and hot water — Part 3: Test report format |
ISO 4064-2:2014 | Water meters for cold potable water and hot water Part 2: Test methods |
IEC 60068-2-67:1995 | Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components |
ISO/IEC Guide 99:2007 | International vocabulary of metrology Basic and general concepts and associated terms (VIM) |
OIML R 75-1 : 2002 | HEAT METERS - PART 1: GENERAL REQUIREMENTS |
EN 14154-3:2005+A2:2011 | Water meters - Part 3: Test methods and equipment |
ISO 8316:1987 | Measurement of liquid flow in closed conduits — Method by collection of the liquid in a volumetric tank |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 14154-2:2005+A2:2011 | Water meters - Part 2: Installation and conditions of use |
OIML R 49-1 : 2013 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
OIML R 49-2 : 2013 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS |
IEC 60359:2001 | Electrical and electronic measurement equipment - Expression of performance |
OIML R 117-3 : 2014 | DYNAMIC MEASURING SYSTEMS FOR LIQUIDS OTHER THAN WATER - PART 3: TEST REPORT FORMAT |
ISO 7194:2008 | Measurement of fluid flow in closed conduits — Velocity-area methods of flow measurement in swirling or asymmetric flow conditions in circular ducts by means of current-meters or Pitot static tubes |
ISO 7005-1:2011 | Pipe flanges — Part 1: Steel flanges for industrial and general service piping systems |
IEC 60381-2:1978 | Analogue signals for process control systems. Part 2: Direct voltage signals |
ISO 6316:2012 | Hot-rolled steel strip of structural quality |
ISO 4064-1:2014 | Water meters for cold potable water and hot water Part 1: Metrological and technical requirements |
ISO 4006:1991 | Measurement of fluid flow in closed conduits — Vocabulary and symbols |
OIML R 117-1 : 2007 | DYNAMIC MEASURING SYSTEMS FOR LIQUIDS OTHER THAN WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
OIML R 75-2 : 2002 | HEAT METERS - PART 2: TYPE APPROVAL TESTS AND INITIAL VERIFICATION TESTS |