• Shopping Cart
    There are no items in your cart

NEMA SG 4:2009(R2013)

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

ALTERNATING CURRENT HIGH-VOLTAGE CIRCUIT BREAKERS

Withdrawn date

21-04-2023

Published date

03-12-2013

Sorry this product is not available in your region.

Foreword
Section 1 - GENERAL
  1.1 Scope
  1.2 References
  1.3 Definition
      1.3.1 Applicable American National Standards
Section 2 - RATING STANDARDS
  2.1 Applicable American National Standards
Section 3 - FUNCTIONAL COMPONENTS AND REQUIREMENTS
  3.1 Applicable American National Standards
  3.2 Operating Mechanisms For Outdoor Circuit Breakers
      3.2.1 All Operating Mechanisms
      3.2.2 For Pneumatic Mechanisms Only
      3.2.3 For Spring Charge Mechanisms
      3.2.4 For Hydraulic Mechanisms
  3.3 Requirements for Terminals and Connections
      3.3.1 Threaded Terminals
      3.3.2 Flat Terminals
      3.3.3 Ground Terminals
  3.4 Instrument Current Transformers
      3.4.1 Ratings
      3.4.2 Characteristics
      3.4.3 Test Procedures
  3.5 Undervoltage Trip Device
  3.6 Secondary and Control Wiring (Small Wiring)
Section 4 - TESTING STANDARDS
  4.1 Applicable American National Standards
  4.2 Radio Influence Voltage Tests as Applicable
      (Design Test)
  4.3 Noise Requirements
      4.3.1 Terminology and Definitions
      4.3.2 Noise Exposure Conditions
      4.3.3 Noise Level
      4.3.4 Noise Measurement Equipment
      4.3.5 Design Tests
Section 5 - SPECIAL APPLICATION
  5.1 Repetitive Duty Circuit Breakers for Arc Furnace
      Switching
      5.1.3 Operating Conditions
      5.1.4 Conditions of the Circuit Breaker
      5.1.5 Minimum Operations Under Fault Conditions
Section 6 - RECOMMENDED INSTALLATION, OPERATION, AND
            MAINTENANCE PROCEDURES
  6.1 General
Appendices
A BUSHING POTENTIAL DEVICES FOR TANK-TYPE OUTDOOR OIL
  CIRCUIT BREAKERS
B TYPICAL CONNECTION FOR SECONDARY BURDENS

Comprehends: - All ratings for outdoor circuit breakers above 1000 volts for alternating-current service.

DocumentType
Standard
PublisherName
National Electrical Manufacturers Association
Status
Withdrawn

IEEE 693-2005 IEEE Recommended Practice for Seismic Design of Substations
IEEE DRAFT 693 : D9 2004 SEISMIC DESIGN OF SUBSTATIONS
IEEE 242-2001 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems (IEEE Buff Book)
ASHRAE 90.4 : 2016 ENERGY STANDARD FOR DATA CENTERS
IEEE C37.04-1999 IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers
IEEE C37.12-2008 REDLINE IEEE Guide for Specifications of High-Voltage Circuit Breakers (over 1000 Volts)
IEEE 1566-2015 IEEE Standard for Performance of Adjustable-Speed AC Drives Rated 375 kW and Larger

IEEE C37.12-2008 SPECIFICATION GUIDE FOR AC HIGH-VOLTAGE CIRCUIT BREAKERS BASED ON A SYMMETRICAL CURRENT BASIS
ASME PV CODE 8 DIV 2 : 2017 BOILER AND PRESSURE VESSEL CODE - RULES FOR CONSTRUCTION OF PRESSURE VESSELS DIVISION 2- ALTERNATIVE RULES
ANSI/ASA S1.1:2013 ACOUSTICAL TERMINOLOGY
ANSI S1.4 : 1983 SPECIFICATION FOR SOUND LEVEL METERS
NEMA 107:2016 Methods of Measurement of Radio Influence Voltage (RIV) of High Voltage Apparatus
ASME PV CODE 8 DIV 1 : 2017 BOILER AND PRESSURE VESSEL CODE - RULES FOR CONSTRUCTION OF PRESSURE VESSELS DIVISION 1
NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
IEEE C57.19.01-2000 IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings
ASME PV CODE 8 DIV 3 : 2017 BPVC Section VIII-BOILER AND PRESSURE VESSEL CODE - RULES FOR CONSTRUCTION OF PRESSURE VESSELS - ALTERNATIVE RULES FOR CONSTRUCTION OF HIGH PRESSURE VESSELS
IEEE C57.19.00 : 2004 GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
IEEE C37.010-1999 IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
ANSI C37.85 : 1989 ALTERNATING-CURRENT HIGH-VOLTAGE POWER VACUUM INTERRUPTERS - SAFETY REQUIREMENTS FOR X-RADIATION LIMITS
ANSI C84.1 : 2016 ELECTRIC POWER SYSTEMS AND EQUIPMENT - VOLTAGE RATINGS (60 HERTZ)
IEEE C37.11-2014 IEEE Standard Requirements for Electrical Control for AC High-Voltage (>1000 V) Circuit Breakers
IEEE C2-2017 NATIONAL ELECTRICAL SAFETY CODE (NESC)(R)
NFPA 70E : 2018 ELECTRICAL SAFETY IN THE WORKPLACE
IEEE C37.082-1982 IEEE Standard Methods for the Measurement of Sound Pressure Levels of AC Power Circuit Breakers
IEEE C37.011-2011 REDLINE IEEE Guide for the Application of Transient Recovery Voltage for AC High-Voltage Circuit Breakers
IEEE C37.06-2009 AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES
IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
IEEE C37.012-2014 IEEE Guide for the Application of Capacitance Current Switching for AC High-Voltage Circuit Breakers Above 1000 V
IEEE C37.015-2009 IEEE Guide for the Application of Shunt Reactor Switching
NEMA CC1 : 2009(R2015) ELECTRIC POWER CONNECTORS FOR SUBSTATIONS
IEEE C50.13 : 2014 CYLINDRICAL-ROTOR 50 HZ AND 60 HZ, SYNCHRONOUS GENERATORS RATED 10 MVA AND ABOVE
IEEE C37.04-1999 IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.