NFPA 850:2020
Current
The latest, up-to-date edition.
Recommended Practice for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations
Hardcopy
English
24-11-2019
Chapter 1 Administration
1.1 Scope.
1.2 Purpose.
1.3 Application.
1.4 Equivalency.
1.5 Units.
Chapter 2 Referenced Publications
2.1 General.
2.2 NFPA Publications.
2.3 Other Publications.
2.4 References for Extracts in Recommendations Sections.
Chapter 3 Definitions
3.1 General.
3.2 NFPA Official Definitions.
3.3 General Definitions.
Chapter 4 Fire Protection Design Process
4.1 General.
4.2 Stakeholders.
4.3 Inputs to the Design Process.
4.4 Fire Protection Design Basis Process.
4.5 Fire Protection Design Basis Document (Deliverables).
Chapter 5 Fire Risk Control Program
5.1 General.
5.2 Management Policy and Direction.
5.3 Fire Risk Control Program.
5.4 Fire Protection Program.
5.5 Identification of Fire Hazards of Materials.
Chapter 6 General Plant Design
6.1 Plant Arrangement.
6.2 Life Safety.
6.3 Building Construction Materials.
6.4 Smoke and Heat Venting, Heating, Ventilating, and Air Conditioning.
6.5 Containment and Drainage.
6.6 Emergency Lighting.
6.7 Lightning Protection.
Chapter 7 General Fire Protection Systems and Equipment
7.1 General.
7.2 Water Supply.
7.3 Valve Supervision.
7.4 Supply Mains, Yard Mains, Hydrants, and Building Standpipes.
7.5 Portable Fire Extinguishers.
7.6 Fire Suppression Systems and Equipment — General Requirements.
7.7 Fire-Signaling Systems.
7.8 Commissioning and Maintenance.
Chapter 8 Fire Protection for the Construction Site
8.1 Introduction.
8.2 Administration.
8.3 Site Clearing, Excavation, Tunneling, and Construction Equipment.
8.4 Construction Warehouses, Shops, and Offices.
8.5 Construction Site Lay-Down Areas.
8.6 Temporary Construction Materials.
8.7 Underground Mains, Hydrants, and Water Supplies.
8.8 Manual Fire-Fighting Equipment.
Chapter 9 Fuels, Common Equipment, and Protection
9.1 General.
9.2 Flammable Gases.
9.3 Combustible Liquids.
9.4 Flammable Liquids.
9.5 Solid Fuels.
9.6 Hydraulic Control System.
9.7 Electrical Equipment.
9.8 Storage Rooms, Offices, and Shops.
9.9 Oil Storage Areas.
9.10 Warehouses.
9.11 Fire Pumps.
9.12 Cooling Towers.
9.13 Auxiliary Boilers.
9.14 Vehicle Repair Facilities.
9.15 Air Compressors.
Chapter 10 Turbines, Generators, and Internal Combustion Engines
10.1 General.
10.2 Application of Chapters 4 Through 9.
10.3 Turbine and Internal Combustion Engine Generators.
10.4 Combined Cycle Units.
Chapter 11 Alternative Fuels
11.1 General.
11.2 Application of Chapters 4 Through 10.
11.3 Design and Equipment Arrangement.
11.4 Risk Considerations for MSW.
11.5 Risk Considerations for RDF.
11.6 Risk Considerations for Biomass Fuels.
11.7 Risk Considerations for Tire Derived Fuels.
11.8 Other Alternative Fuels and Processes.
Chapter 12 Power Boilers
12.1 General.
12.2 Application of Chapters 4 Through 11.
12.3 Design and Equipment Arrangement.
Chapter 13 Wind Turbines
13.1 General.
13.2 Application of Chapters 4 Through 10.
13.3 Design and Equipment Arrangement.
13.4 Risk Consideration.
13.5 Hazard Protection.
Chapter 14 Solar Generation
14.1 General.
14.2 Application of Chapters 4 Through 10.
14.3 Design and Equipment Arrangement.
14.4 Risk Considerations.
14.5 Hazard Protection.
Chapter 15 Geothermal Generation
15.1 General.
15.2 Application of Chapters 4 Through 10.
15.3 Design and Equipment Arrangement.
15.4 Risk Considerations.
15.5 Hazard Protection.
Chapter 16 Integrated Gasification Combined-Cycle (IGCC)
16.1 General.
16.2 Application of Chapters 4 Through 10.
16.3 Design and Equipment Arrangement.
16.4 Risk Considerations.
16.5 Hazard Protection.
Chapter 17 Hydroelectric Generation
17.1 General.
17.2 Application of Chapters 4 Through 10.
17.3 Design and Equipment Arrangement.
17.4 Risk Considerations. (Reserved)
17.5 Hazard Protection.
Chapter 18 High-Voltage Direct Current (HVDC) Converter Stations
18.1 General.
18.2 Application of Chapters 4 Through 9.
18.3 Design and Equipment Arrangement.
18.4 Risk Considerations.
18.5 Hazard Protection.
Chapter 19 Flywheel Energy Systems
19.1 General.
19.2 Application of Chapters 4 Through 10.
19.3 Design and Equipment Arrangement.
19.4 Risk Consideration.
19.5 Hazard Protection.
Chapter 20 Compressed Air Energy Storage (CAES)
20.1 General.
20.2 Application of Chapters 4 Through 10.
20.3 Design and Equipment Arrangement.
20.4 Risk Consideration.
20.5 Hazard Protection.
Annex A Explanatory Material
Annex B Sample Fire Report
Annex C Fire Tests
Annex D Loss Experience
Annex E Fire Protection Design Basis Document
Annex F Informational References
This document provides recommendations for fire prevention and fire protection for electric generating plants and high voltage direct current converter stations, except as follows: Advanced light water reactor electric generating plants are addressed in NFPA 804; nuclear power plants are addressed in NFPA 805; and fuel cells are addressed in NFPA 853.
DocumentType |
Standard
|
ISBN |
978-145592593-3
|
Pages |
93
|
ProductNote |
This standard is also refers to OSHA 29 CFR 1910.146.
|
PublisherName |
National Fire Protection Association
|
Status |
Current
|
Supersedes |
NFPA 654 : 2020 | Standard for the Prevention of Fire and Dust Explosions from the Manufacturing, Processing, and Handling of Combustible Particulate Solids |
NFPA 701:2019 | Standard Methods of Fire Tests for Flame Propagation of Textiles and Films |
ASTM E 108 : 2017 | Standard Test Methods for Fire Tests of Roof Coverings |
NFPA 31 : 2016 | INSTALLATION OF OIL-BURNING EQUIPMENT |
NFPA 96 : 2017 | VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS |
NFPA 30A : 2018 | MOTOR FUEL DISPENSING FACILITIES AND REPAIR GARAGES |
NFPA 80 : 2019 | Standard for Fire Doors and Other Opening Protectives |
NFPA 120 : 2020 | Standard for Fire Prevention and Control in Coal Mines |
NFPA 253:2019 | Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source |
ASTM E 814 : 2013 | Standard Test Method for Fire Tests of Penetration Firestop Systems |
NFPA 1901:2016 | AUTOMOTIVE FIRE APPARATUS |
NFPA 214 : 2016 | WATER-COOLING TOWERS |
NFPA 101 : 2018 | LIFE SAFETY CODE |
ASTM D 92 : 2018 | Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester |
ASME B31.1 : 2018 | Power Piping |
NFPA 22 : 2018 | WATER TANKS FOR PRIVATE FIRE PROTECTION |
NFPA 804 : 2015 | FIRE PROTECTION FOR ADVANCED LIGHT WATER REACTOR ELECTRIC GENERATING PLANTS |
NFPA 24 : 2019 | Standard for the Installation of Private Fire Service Mains and Their Appurtenances |
NFPA 16 : 2019 | Standard for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems |
NFPA 1982 : 2018 | Standard on Personal Alert Safety Systems (PASS) |
NFPA 90A : 2018 | INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS |
NFPA 80A : 2017 | PROTECTION OF BUILDINGS FROM EXTERIOR FIRE EXPOSURES |
NFPA 51B:2019 | Fire Prevention During Welding, Cutting, and Other Hot Work |
NFPA 17 : 2017 | DRY CHEMICAL EXTINGUISHING SYSTEMS |
NFPA 20 : 2019 | Standard for the Installation of Stationary Pumps for Fire Protection |
ASTM E 84 : 2016 | Standard Test Method for Surface Burning Characteristics of Building Materials |
NFPA 704 : 2017 | STANDARD SYSTEM FOR THE IDENTIFICATION OF THE HAZARDS OF MATERIALS FOR EMERGENCY RESPONSE |
NFPA 750:2019 | Standard on Water Mist Fire Protection Systems |
NFPA 600:2020 | Facility Fire Brigades |
NFPA 1221:2019 | Standard for the Installation, Maintenance, and Use of Emergency Services Communications Systems |
NFPA 90B : 2018 | INSTALLATION OF WARM AIR HEATING AND AIR-CONDITIONING SYSTEMS |
NFPA 501A : 2017 | FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES, AND COMMUNITIES |
NFPA 12A : 2018 | HALON 1301 FIRE EXTINGUISHING SYSTEMS |
NFPA 15 : 2017 | WATER SPRAY FIXED SYSTEMS FOR FIRE PROTECTION |
NFPA 601: 2020 | Standard for Security Services in Fire Loss Prevention |
NFPA 664 : 2017 | PREVENTION OF FIRES AND EXPLOSIONS IN WOOD PROCESSING AND WOODWORKING FACILITIES |
NFPA 10 : 2018 | PORTABLE FIRE EXTINGUISHERS |
ASTM E 136 : 2019 | Standard Test Method for Assessing Combustibility of Materials Using a Vertical Tube Furnace at 750°C |
NFPA 12 : 2018 | CARBON DIOXIDE EXTINGUISHING SYSTEMS |
UL 723:11ED 2018-04-19 | Test for Surface Burning Characteristics of Building Materials |
NFPA 18A : 2017 | WATER ADDITIVES FOR FIRE CONTROL AND VAPOR MITIGATION |
NFPA 77 : 2019 | Recommended Practice on Static Electricity |
NFPA 85:2019 | Boiler and Combustion Systems Hazards Code |
NFPA 58:2020 | Liquefied Petroleum Gas Code. |
NFPA 59A : 2019 | Standard for the Production, Storage, and Handling of Liquefied Natural Gas (LNG) |
NFPA 86 : 2019 | Standard for Ovens and Furnaces<br> |
NFPA 1142 : 2017 | WATER SUPPLIES FOR SUBURBAN AND RURAL FIRE FIGHTING |
IEEE C2-2017 | NATIONAL ELECTRICAL SAFETY CODE (NESC)(R) |
NFPA 11 : 2016 | LOW-, MEDIUM-, AND HIGH-EXPANSION FOAM |
NFPA 1962 : 2018 | CARE, USE, INSPECTION, SERVICE TESTING, AND REPLACEMENT OF FIRE HOSE, COUPLINGS, NOZZLES, AND FIRE HOSE APPLIANCES |
NFPA 805 : 2015 | PERFORMANCE-BASED STANDARD FOR FIRE PROTECTION FOR LIGHT WATER REACTOR ELECTRIC GENERATING PLANTS |
NFPA 56 : 2017 | FIRE AND EXPLOSION PREVENTION DURING CLEANING AND PURGING OF FLAMMABLE GAS PIPING SYSTEMS |
NFPA 1 : 2018 | FIRE CODE |
NFPA 25 : 2020 | Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems |
NFPA 652 : 2019 | FUNDAMENTALS OF COMBUSTIBLE DUST |
NFPA 72:2019 | National Fire Alarm and Signaling Code |
NFPA 499 : 2017 | CLASSIFICATION OF COMBUSTIBLE DUSTS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
NFPA 14 : 2019 | Standard for the Installation of Standpipe and Hose Systems |
NFPA 1971:2018 | Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting |
NFPA 853:2020 | Standard for the Installation of Stationary Fuel Cell Power Systems |
NFPA 110:2019 | Standard for Emergency and Standby Power Systems |
NFPA 30 : 2018 | FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE |
NFPA 257 : 2017 | FIRE TEST FOR WINDOW AND GLASS BLOCK ASSEMBLIES |
NFPA 70 : 2020 | National Electrical Code (NEC) Softbound |
NFPA 54 : 2018 | NATIONAL FUEL GAS CODE |
NFPA 1981 : 2019 | Standard on Open-Circuit Self-Contained Breathing Apparatus (SCBA) for Emergency Services |
NFPA 1143 : 2018 | WILDLAND FIRE MANAGEMENT |
NFPA 75:2020 | Standard for the Fire Protection of Information Technology Equipment |
NFPA 37 : 2018 | INSTALLATION AND USE OF STATIONARY COMBUSTION ENGINES AND GAS TURBINES |
IEC 62305:2024 SER | Protection against lightning - ALL PARTS |
NFPA 13 : 2019 | Standard for the Installation of Sprinkler Systems |
NFPA 2010 : 2020 | Standard for Fixed Aerosol Fire Extinguishing Systems |
API 537 : 2017 | FLARE DETAILS FOR PETROLEUM, PETROCHEMICAL, AND NATURAL GAS INDUSTRIES |
ASTM E 119 : 2007 | Standard Test Methods for Fire Tests of Building Construction and Materials |
NFPA 69 : 2019 | Standard on Explosion Prevention Systems |
NFPA 55:2020 | Compressed Gases and Cryogenic Fluids Code |
NFPA 1144 : 2018 | REDUCING STRUCTURE IGNITION HAZARDS FROM WILDLAND FIRE |
NFPA 252 : 2017 | STANDARD METHODS OF FIRE TESTS OF DOOR ASSEMBLIES |
NFPA 92 : 2018 | SMOKE CONTROL SYSTEMS |
NFPA 497 : 2017 | CLASSIFICATION OF FLAMMABLE LIQUIDS, GASES, OR VAPORS AND OF HAZARDOUS (CLASSIFIED) LOCATIONS FOR ELECTRICAL INSTALLATIONS IN CHEMICAL PROCESS AREAS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.