Introduction
1 Scope and object
2 Normative references
3 Definitions and terms [see IEC 50(426)]
4 General
4.1 General requirements
4.2 Documentation
5 Selection of electrical apparatus (excluding cables
and conduits)
5.1 Specific information
5.2 Selection according to zones
5.3 Selection according to the ignition temperature
of the gas or vapour
5.4 Selection according to apparatus grouping
5.5 External influences
6 Protection from dangerous (incendive) sparking
6.1 Danger from live parts
6.2 Danger from exposed and extraneous conductive
parts
6.3 Potential equalization
6.4 Static electricity
6.5 Lightning protection
6.6 Electromagnetic radiation
6.7 Cathodically protected metallic parts
7 Electrical protection
8 Emergency switch-off and electrical isolation
8.1 Emergency switch-off
8.2 Electrical isolation
9 Wiring systems
9.1 General
9.2 Cable systems for Zone 0
9.3 Cable systems for Zones 1 and 2
9.4 Conduit systems
10 Additional requirements for type of protection "d"
- Flameproof enclosures
10.1 Solid obstacles
10.2 Protection of flameproof joints
10.3 Cable entry systems
10.4 Motors supplied at varying frequency and
voltage
10.5 Conduit systems
11 Additional requirements for type of protection "e"
- Increased safety
11.1 Degree of production of enclosures (IEC 34-5
and IEC 529)
11.2 Cage induction motors - Thermal protection in
operation
11.3 Wiring systems
11.4 Resistance heating devices
12 Additional requirements for type of protection "i"
- Intrinsic safety
12.1 Introduction
12.2 Installation for Zones 1 and 2
12.3 Installations for Zone 0
13 Additional requirements for type of protection "p"
- Pressurized apparatus
13.1 Ducting
13.2 Actions to be taken on failure of
pressurization
13.3 Multiple pressurized enclosures with a common
safety device
13.4 Purging
14 Additional requirements for apparatus for use in
Zone 2
14.1 Degree of protection of enclosures (IEC 34-5
and IEC 529)
14.2 Energy-limited apparatus and circuits
14.3 Wiring systems
14.4 Motors supplied at varying frequency and voltage
15 Special applications (additional clause)
15.1 Battery operated vehicles
15.2 Personal electrical apparatus
Annex A (normative) Verification of intrinsically safe
circuits with more than one associated
apparatus with linear current/voltage
characteristics
Annex B (informative) Methods of determining the maximum
system voltages and currents in
intrinsically safe circuits with more
than one associated apparatus with
linear current/voltage characteristics
(as required by Annex A)
Annex C (informative) Frictional sparking risks with light
metals and their alloys
Annex D (informative) Determination of cable parameters
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Gives requirements for design, selection and erection of electrical installations in explosive gas atmospheres, which are in addition to requirements for installations in non-hazardous areas. Applicable to all electrical equipment and installations in hazardous areas whether, temporary, permanent, portable, transportable or hand-held. Applicable to installations at all voltages.
| Committee |
EXL/31/3
|
| DocumentType |
Standard
|
| Pages |
60
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| DEFSTAN 00-101(PT3)/2(2008) : 2008 | DESIGN STANDARDS FOR EXPLOSIVES SAFETY IN MOD SHIPS AND SUBMARINES - PART 3: ELECTRICAL EQUIPMENT AND INSTALLATION |
| EI TP PETROLEUM ROAD TANKER : 2010 | PETROLEUM ROAD TANKER DESIGN AND CONSTRUCTION |
| EI MODEL CODE SAFE PRACTICE PT1 : 2010 | THE SELECTION, INSTALLATION, INSPECTION, AND MAINTENANCE OF ELECTRICAL AND NON ELECTRICAL APPARATUS IN HAZARDOUS AREAS |
| IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
| IEC 60079-10:2002 | Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas |
| IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
| IEC 60079-17:2013 | Explosive atmospheres - Part 17: Electrical installations inspection and maintenance |
| IEC 60332-1:1993 | Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable |
| IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
| IEC 60614-2-5:1992 | Specifications for conduits for electrical installations - Part 2: Particular specifications for conduits - Section 5: Flexible conduits |
| IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
| IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
| IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| IEC 60755:2017 | General safety requirements for residual current operated protective devices |
| IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
| IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
| IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
| IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.