PREN 12150-2 : DRAFT 2017
Current
The latest, up-to-date edition.
GLASS IN BUILDING - THERMALLY TOUGHENED SODA LIME SILICATE SAFETY GLASS - PART 2: PRODUCT STANDARD
28-11-2017
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Assessment and verification of constancy of
performance - AVCP
6 Marking and/or labelling
Annex A (normative) - Factory production control
Annex B (informative) - Tests for factory production
control
Annex C (normative) - Type testing of spectrophotometric
and energy characteristics
Annex D (normative) - Type testing and sampling for
fragmentation, mechanical strength and pendulum
body impact tests
Annex E (informative) - Provisions for voluntary
involvement of third party(ies)
Annex ZA (informative) - Relationship of this European
Standard with Regulation (EU) No.305/2011
Bibliography
Describes the assessment and verification of constancy of performances and the factory production control of flat thermally toughened soda lime silicate safety glass for use in buildings.
Committee |
TC 129
|
DocumentType |
Draft
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
17/30365055 DC | Identical |
BS 6510:2005 | Steel-framed windows and glazed doors |
04/30100932 DC : DRAFT AUG 2004 | BS 6510 - STEEL-FRAMED WINDOWS AND GLAZED DOORS |
03/100998 DC : DRAFT MAR 2003 | EN 13022-3 - GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - PART 3: ASSEMBLY RULES |
EN 673:2011 | Glass in building - Determination of thermal transmittance (U value) - Calculation method |
EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
EN 1096-1:2012 | Glass in building - Coated glass - Part 1: Definitions and classification |
EN 12898:2001 | Glass in building - Determination of the emissivity |
305/2011 : 2011 AMD 2 2014 | REGULATION (EU) NO 305/2011 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 9 MARCH 2011 LAYING DOWN HARMONISED CONDITIONS FOR THE MARKETING OF CONSTRUCTION PRODUCTS AND REPEALING COUNCIL DIRECTIVE 89/106/EEC (TEXT WITH EEA RELEVANCE) |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN 13501-5:2016 | Fire classification of construction products and building elements - Part 5: Classification using data from external fire exposure to roofs tests |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
PREN 16612 : DRAFT 2017 | GLASS IN BUILDING - DETERMINATION OF THE LATERAL LOAD RESISTANCE OF GLASS PANES BY CALCULATION |
EN 1288-3:2000 | Glass in building - Determination of the bending strength of glass - Part 3: Test with specimen supported at two points (four point bending) |
EN 572-2:2012 | Glass in building - Basic soda lime silicate glass products - Part 2: Float glass |
EN 12150-1:2015 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 1: Definition and description |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
EN 1063:1999 | Glass in building - Security glazing - Testing and classification of resistance against bullet attack |
EN 572-4:2012 | Glass in building - Basic soda lime silicate glass products - Part 4: Drawn sheet glass |
ISO 9001:2015 | Quality management systems — Requirements |
EN 572-1:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties |
EN 356:1999 | Glass in building - Security glazing - Testing and classification of resistance against manual attack |
EN 572-5:2012 | Glass in building - Basic soda lime silicate glass products - Part 5: Patterned glass |
EN 572-8:2012+A1:2016 | Glass in building - Basic soda-lime silicate glass products - Part 8: Supplied and final cut sizes |
ISO 9385:1990 | Glass and glass-ceramics Knoop hardness test |
EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
EN 15998:2010 | Glass in building - Safety in case of fire, fire resistance - Glass testing methodology for the purpose of classification |
EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
EN 1096-2:2012 | Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.