EN 13051:2001
|
Curtain Walling - Watertightness - Site test |
EN 13022-1:2014
|
Glass in building - Structural sealant glazing - Part 1: Glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing |
EN 13168:2012+A1:2015
|
Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification |
ISO 140-5:1998
|
Acoustics Measurement of sound insulation in buildings and of building elements Part 5: Field measurements of airborne sound insulation of faade elements and faades |
EN 12153:2000
|
Curtain walling - Air permeability - Test method |
EN 14509:2013
|
Self-supporting double skin metal faced insulating panels - Factory made products - Specifications |
EN 13116:2001
|
Curtain walling - Resistance to wind load - Performance requirements |
EN 13050:2011
|
Curtain Walling - Watertightness - Laboratory test under dynamic condition of air pressure and water spray |
EN 13363-2:2005/AC:2006
|
SOLAR PROTECTION DEVICES COMBINED WITH GLAZING - CALCULATION OF TOTAL SOLAR ENERGY TRANSMITTANCE AND LIGHT TRANSMITTANCE - PART 2: DETAILED CALCULATION METHOD |
EN 1364-3:2014
|
FIRE RESISTANCE TESTS FOR NON-LOADBEARING ELEMENTS - PART 3: CURTAIN WALLING - FULL CONFIGURATION (COMPLETE ASSEMBLY) |
EN 1096-4:2004
|
Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard |
EN ISO 9046:2004
|
Building construction - Jointing products - Determination of adhesion/cohesion properties of sealants at constant temperature (ISO 9046:2002) |
EN 12758:2011
|
Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
EN 410:2011
|
Glass in building - Determination of luminous and solar characteristics of glazing |
EN 1279-1:2004/AC:2006
|
GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION |
EN 13164:2012+A1:2015
|
Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification |
EN 1999-1-1:2007/A2:2013
|
EUROCODE 9: DESIGN OF ALUMINIUM STRUCTURES - PART 1-1: GENERAL STRUCTURAL RULES |
EN 15434:2006+A1:2010
|
Glass in building - Product standard for structural and/or ultra-violet resistant sealant (for use with structural sealant glazing and/or insulating glass units with exposed seals) |
EN 1991-1-3:2003/A1:2015
|
EUROCODE 1 - ACTIONS ON STRUCTURES - PART 1-3: GENERAL ACTIONS - SNOW LOADS |
EN 15651-2:2017
|
Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing |
EN ISO 9047:2003/AC:2009
|
BUILDING CONSTRUCTION - JOINTING PRODUCTS - DETERMINATION OF ADHESION/COHESION PROPERTIES OF SEALANTS AT VARIABLE TEMPERATURES |
EN ISO 12631:2017
|
Thermal performance of curtain walling - Calculation of thermal transmittance (ISO 12631:2017) |
EN 13166:2012+A2:2016
|
Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
EN 13501-2:2016
|
Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
EN 14019:2016
|
Curtain Walling - Impact resistance - Performance requirements |
EN ISO 140-5:1998
|
Acoustics - Measurement of sound insulation in buildings and of building elements - Part 5: Field measurements of airborne sound insulation of façade elements and façades (ISO 140-5:1998) |
EN 12365-1:2003
|
Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 1: Performance requirements and classification |
EN ISO 10591:2005
|
Building construction - Sealants - Determination of adhesion/cohesion properties of sealants after immersion in water (ISO 10591:2005) |
EN 13823:2010+A1:2014
|
REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM |
EN 15651-1:2017
|
Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 1: Sealants for facade elements |
EN 1279-3:2002
|
Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances |
EN 13162:2012+A1:2015
|
Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
EN 13170:2012+A1:2015
|
Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification |
EN 1279-4:2002
|
Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals |
EN ISO 10848-1:2017
|
Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 1: Frame document (ISO 10848-1:2017) |
ENV 13050:2000
|
Curtain walling - Watertightness - Laboratory test under dynamic condition of air pressure and water spray |
EN ISO 140-3:1995/A1:2004
|
ACOUSTICS - MEASUREMENT OF SOUND INSULATION IN BUILDINGS AND OF BUILDING ELEMENTS - PART 3: LABORATORY MEASUREMENTS OF AIRBORNE SOUND INSULATION OF BUILDING ELEMENTS |
EN ISO 10590:2005
|
Building construction - Sealants - Determination of tensile properties of sealants at maintained extension after immersion in water (ISO 10590:2005) |
EN 1991-1-1:2002/AC:2009
|
EUROCODE 1: ACTIONS ON STRUCTURES - PART 1-1: GENERAL ACTIONS - DENSITIES, SELF-WEIGHT, IMPOSED LOADS FOR BUILDINGS |
EN 12365-4:2003
|
Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 4: Recovery after accelerated ageing test method |
EN 13165:2012+A2:2016
|
Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification |
EN 1279-5:2005+A2:2010
|
Glass in building - Insulating glass units - Part 5: Evaluation of conformity |
EN 1364-4:2014
|
Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration |
EN 12155:2000
|
Curtain walling - Watertightness - Laboratory test under static pressure |
EN 13363-1:2003+A1:2007/AC:2008
|
SOLAR PROTECTION DEVICES COMBINED WITH GLAZING - CALCULATION OF SOLAR AND LIGHT TRANSMITTANCE - PART 1: SIMPLIFIED METHOD |
EN 13171:2012+A1:2015
|
Thermal insulation products for buildings - Factory made wood fibre (WF) products - Specification |
EN 12179:2000
|
Curtain walling - Resistance to wind load - Test method |
EN 13167:2012+A1:2015
|
Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification |
EN 1279-2:2002
|
Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration |
EN 13119:2016
|
Curtain walling - Terminology |
EN 13163:2012+A2:2016
|
Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification |
EN 1995-1-1:2004/A2:2014
|
EUROCODE 5: DESIGN OF TIMBER STRUCTURES - PART 1-1: GENERAL - COMMON RULES AND RULES FOR BUILDINGS |
EN ISO 8339:2005
|
Building construction - Sealants - Determination of tensile properties (Extension to break) (ISO 8339:2005) |
EN 1998-1:2004/A1:2013
|
EUROCODE 8: DESIGN OF STRUCTURES FOR EARTHQUAKE RESISTANCE - PART 1: GENERAL RULES, SEISMIC ACTIONS AND RULES FOR BUILDINGS |
EN 1990:2002/A1:2005/AC:2010
|
EUROCODE - BASIS OF STRUCTURAL DESIGN |
EN 1096-3:2012
|
Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
EN 1991-1-4:2005/A1:2010
|
EUROCODE 1: ACTIONS ON STRUCTURES - PART 1-4: GENERAL ACTIONS - WIND ACTIONS |
EN ISO 8340:2005
|
Building construction - Sealants - Determination of tensile properties at maintained extension (ISO 8340:2005) |
EN 13169:2012+A1:2015
|
Thermal insulation products for buildings - Factory made expanded perlite board (EPB) products - Specification |
EN 13022-2:2014
|
Glass in building - Structural sealant glazing - Part 2: Assembly rules |
EN 12152:2002
|
Curtain walling - Air permeability - Performance requirements and classification |
EN 12154:1999
|
Curtain walling - Watertightness - Performance requirements and classification |
EN 12600:2002
|
Glass in building - Pendulum test - Impact test method and classification for flat glass |
EN 1993-1-1:2005/A1:2014
|
EUROCODE 3: DESIGN OF STEEL STRUCTURES - PART 1-1: GENERAL RULES AND RULES FOR BUILDINGS |
EN ISO 11600:2003/A1:2011
|
BUILDING CONSTRUCTION - JOINTING PRODUCTS - CLASSIFICATION AND REQUIREMENTS FOR SEALANTS |
EN 1096-2:2012
|
Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings |
EN ISO 10848-2:2017
|
Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 2: Application to Type B elements when the junction has a small influence (ISO 10848-2:2017) |