GUIDE FOR THE APPLICATION OF THE EUROPEAN STANDARD EN 50160
Hardcopy , PDF
English
01-01-2013
Foreword
Introduction
1 Scope
2 Historical overview of the Standard and its development
3 The Standard
4 Position of EN 50160 in the standards scenario
Annex A (informative) - Distributed generation and its
impact on the supply voltage
Annex B (informative) - Voltage/current components in the
frequency range 2 kHz - 150 kHz and its impact
on the supply voltage
Annex C (informative) - Overvoltages
Annex D (informative) - Abbreviations
Bibliography
Gives background information and explanations on EN 50160 with regard to the history of its development as well as to its correct application.
DevelopmentNote |
Supersedes I.S. CLC TR 50422. (09/2013)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Supersedes |
Standards | Relationship |
CLC/TR 50422:2013 | Identical |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
IEC 60038:2009 | IEC standard voltages |
EN 61000-4-30:2015/AC:2017-01 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-30: TESTING AND MEASUREMENT TECHNIQUES - POWER QUALITY MEASUREMENT METHODS (IEC 61000-4-30:2015/COR1:2016) |
EN 50438:2013 | REQUIREMENTS FOR MICRO-GENERATING PLANTS TO BE CONNECTED IN PARALLEL WITH PUBLIC LOW-VOLTAGE DISTRIBUTION NETWORKS |
2006/95/EC : 2006 | DIRECTIVE 2006/1995/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 12 DECEMBER 2006 ON THE HARMONISATION OF THE LAWS OF MEMBER STATES RELATING TO ELECTRICAL EQUIPMENT DESIGNED FOR USE WITHIN CERTAIN VOLTAGE LIMITS (CODIFIED VERSION) (TEXT WITH EEA RELEVANCE) |
HD 60364-4-443:2016 | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching |
IEC TR 61000-1-1:1992 | Electromagnetic compatibility (EMC) - Part 1: General - Section 1: Application and interpretation of fundamental definitions and terms |
IEC TR 60725:2012 | Consideration of reference impedances and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ≤75 A per phase |
1989/336/EEC : 1989 | COUNCIL DIRECTIVE OF 3 MAY 1989 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
HD 472 S1:1989/AC:2013 | NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS |
EN 50550:2011/A1:2014 | POWER FREQUENCY OVERVOLTAGE PROTECTIVE DEVICE FOR HOUSEHOLD AND SIMILAR APPLICATIONS (POP) |
HD 60364-4-442:2012 | Low-voltage electrical installations - Part 4-442: Protection for safety - Protection of low-voltage installations against temporary overvoltages due to earth faults in the high-voltage system and due to faults in the low voltage system |
EN 61000-2-2:2002/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS (IEC 61000-2-2:2002/A1:2017) |
IEC TR 61000-2-14:2006 | Electromagnetic compatibility (EMC) - Part 2-14: Environment - Overvoltages on public electricity distribution networks |
IEC 61000-4-15:2010 | Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC TR 61000-3-7:2008 | Electromagnetic compatibility (EMC) - Part 3-7: Limits - Assessment of emission limits for the connection of fluctuating installations to MV, HV and EHV power systems |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC TR 61000-2-1:1990 | Electromagnetic compatibility (EMC) - Part 2: Environment - Section 1: Description of the environment - Electromagnetic environment for low-frequency conducted disturbances and signalling in public power supply systems |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEEE 1564-2014 | IEEE Guide for Voltage Sag Indices |
EN 61000-3-12:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011) |
EN 50065-1:2011 | Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 1: General requirements, frequency bands and electromagnetic disturbances |
IEC TR 61000-3-6:2008 | Electromagnetic compatibility (EMC) - Part 3-6: Limits - Assessment of emission limits for the connection of distorting installations to MV, HV and EHV power systems |
IEC TR 61000-2-8:2002 | Electromagnetic compatibility (EMC) - Part 2-8: Environment - Voltage dips and short interruptions on public electric power supply systems with statistical measurement results |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 61000-4-15:2011 | Electromagnetic compatibility (EMC) - Part 4-15: Testing and measurement techniques - Flickermeter - Functional and design specifications |
EN 60038:2011 | CENELEC STANDARD VOLTAGES (IEC 60038:2009, MODIFIED) |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.