Low-voltage electrical installations - Part 7-712: Requirements for special installations or locations - Photovoltaic (PV) systems
Hardcopy , PDF
Spanish, Castilian, English
15-02-2017
This section applies to the electrical installation of PV systems intended to supply all or part of an installation and/or feeding of electricity into the public grid.
In this section, the equipment of a PV system, like any other item of equipment, is dealt with only so far as its selection and application in the installation is concerned.
The electrical installation of a PV system starts from a PV module or a set of PV modules connected in series with their cables, provided by the PV module manufacturer, up to the user installation or the utility supply point.
Requirements of this document apply to
PV systems for supply to an installation which is not connected to a system for distribution of electricity to the public,
PV systems for supply to an installation in parallel with a system for distribution of electricity to the public,
PV systems for supply to an installation as an alternative to a system for distribution of electricity to the public,
appropriate combination of the above.
Requirements for PV systems with batteries or other energy storage methods are under consideration.
| Committee |
CTN 202/SC 64
|
| DocumentType |
Standard
|
| Pages |
35
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Current
|
| Standards | Relationship |
| HD 60364-7-712:2016 | Identical |
| EN 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
| EN 60269-6:2011 | Low-voltage fuses - Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems |
| HD 60364-5-53:2015/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
| EN 60904-3:2016 | Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data |
| IEC 62423:2009 | Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses |
| IEC 60269-6:2010 | Low-voltage fuses - Part 6: Supplementary requirements for fuse-links for the protection of solar photovoltaic energy systems |
| HD 60364-4-443:2016 | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Clause 443: Protection against transient overvoltages of atmospheric origin or due to switching |
| EN 62305-4:2011/AC:2016 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES (IEC 62305-4:2010) |
| IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
| EN 50618:2014 | Electric cables for photovoltaic systems |
| IEC 61730-2:2016 | Photovoltaic (PV) module safety qualification - Part 2: Requirements for testing |
| CLC/TS 50539-12:2013 | Low-voltage surge protective devices - Surge protective devices for specific application including d.c. - Part 12: Selection and application principles - SPDs connected to photovoltaic installations |
| HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
| EN 61730-1:2007/A11:2014 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 1: REQUIREMENTS FOR CONSTRUCTION (IEC 61730-1:2004, MODIFIED) |
| EN 62423:2012 | Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses |
| EN 62446:2009 | Grid connected photovoltaic systems – Minimum requirements for system documentation, commissioning tests and inspection |
| EN 60947-3:2009/A2:2015 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 3: SWITCHES, DISCONNECTORS, SWITCH-DISCONNECTORS AND FUSE-COMBINATION UNITS (IEC 60947-3:2008/A2:2015) |
| EN 62305-3:2011 | Protection against lightning - Part 3: Physical damage to structures and life hazard |
| EN 61730-2:2007/A1:2012 | PHOTOVOLTAIC (PV) MODULE SAFETY QUALIFICATION - PART 2: REQUIREMENTS FOR TESTING (IEC 61730-2:2004/A1:2011) |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
| EN 50521:2008/A1:2012 | CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
| IEC 62852:2014 | Connectors for DC-application in photovoltaic systems - Safety requirements and tests |
| IEC 61730-1:2016 | Photovoltaic (PV) module safety qualification - Part 1: Requirements for construction |
| EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
| IEC 61643-11:2011 | Low-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods |
| IEC 60904-3:2016 | Photovoltaic devices - Part 3: Measurement principles for terrestrial photovoltaic (PV) solar devices with reference spectral irradiance data |
| IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
| EN 62109-1:2010 | Safety of power converters for use in photovoltaic power systems - Part 1: General requirements |
| EN 60898-2:2006 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation |
| EN 62305-2:2012 | Protection against lightning - Part 2: Risk management |
| IEC 60898-2:2016 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for AC and DC operation |
| IEC 62109-2:2011 | Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters |
| IEC 62446:2009 | Grid connected photovoltaic systems - Minimum requirements for system documentation, commissioning tests and inspection |
| EN 62109-2:2011 | Safety of power converters for use in photovoltaic power systems - Part 2: Particular requirements for inverters |
| HD 60364-5-551:2010/A11:2016 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-55: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - OTHER EQUIPMENT - CLAUSE 551: LOW-VOLTAGE GENERATING SETS |
| IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
| IEC 62305-4:2010 | Protection against lightning - Part 4: Electrical and electronic systems within structures |
| IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
| IEC 60947-3:2008+AMD1:2012+AMD2:2015 CSV | Low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switch-disconnectors and fuse-combination units |
| IEC 62305-2:2010 | Protection against lightning - Part 2: Risk management |
| IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV | Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment |
| IEC 60947-2:2016 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
| EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
| EN 60947-2:2017 | Low-voltage switchgear and controlgear - Part 2: Circuit-breakers |
| EN 61557-8:2015/AC:2016-06 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
| IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
| IEC 62109-1:2010 | Safety of power converters for use in photovoltaic power systems - Part 1: General requirements |
| EN 50539-11 : 2013 AMD 1 2014 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - SURGE PROTECTIVE DEVICES FOR SPECIFIC APPLICATION INCLUDING D.C. - PART 11: REQUIREMENTS AND TESTS FOR SPDS IN PHOTOVOLTAIC APPLICATIONS |
| EN 62852:2015 | Connectors for DC-application in photovoltaic systems - Safety requirements and tests |
| IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
| EN 61557-9:2015/AC:2017-02 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017) |
| IEC 62305-3:2010 | Protection against lightning - Part 3: Physical damage to structures and life hazard |