AS 2118.2-1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Automatic fire sprinkler systems - Wall wetting sprinklers (Drenchers)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Superseded by

AS 2118.2-2010

Language(s)

English

Published date

01-01-1995

€32.89
Excluding VAT

1 - AS 2118.2-1995 AUTOMATIC FIRE SPRINKLER SYSTEMS - WALL WETTING SPRINKLERS (DRENCHERS)
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - SECTION 1 SCOPE AND GENERAL
7 - 1.1 SCOPE
7 - 1.2 NEW DESIGNS AND INNOVATIONS
7 - 1.3 INTERPRETATIONS
7 - 1.4 REFERENCED AND RELATED DOCUMENTS
7 - 1.5 DEFINITIONS
7 - 1.5.1 Assumed area of operation (wall wetting sprinkler system)
7 - 1.5.2 External opening
7 - 1.5.3 Fire compartment
7 - 1.5.4 Fire-source feature
8 - 1.5.5 Radiant heat
8 - 1.5.6 Radiant heat flux
8 - 1.5.7 Receiver building
8 - 1.5.8 Source building
8 - 1.5.9 Wall wetting sprinkler open
8 - 1.5.10 Wall wetting sprinkler sealed
8 - 1.5.11 Worst case exposure fire
8 - 1.6 TYPES OF SYSTEMS
8 - 1.6.1 Sealed wall wetting sprinkler systems
8 - 1.6.2 Open wall wetting sprinkler systems
8 - 1.6.3 Wet systems
8 - 1.6.4 Dry systems
9 - SECTION 2 SYSTEM DESIGN
9 - 2.1 GENERAL
9 - 2.2 SEALED WALL WETTING SPRINKLER SYSTEMS
9 - 2.2.1 Design
9 - 2.2.2 Water supply
9 - 2.2.3 Sprinkler orientation for wet type systems
9 - 2.2.4 Dry systems
9 - 2.3 OPEN WALL WETTING SPRINKLER SYSTEMS
9 - 2.4 MAXIMUM NUMBER OF WALL WETTING SPRINKLERS ON SYSTEM
9 - 2.5 MINIMUM OPERATING PRESSURE
10 - 2.6 AREA TO BE PROTECTED
10 - 2.7 SHIELDING OF WALL WETTING SPRINKLERS
11 - 2.8 SPACING OF WALL WETTING SPRINKLERS
11 - 2.9 DISTANCE OF WALL WETTING SPRINKLERS FROM THE PROTECTED SURFACE
11 - 2.10 SEALED WALL WETTING SPRINKLERS
11 - 2.11 OPEN WALL WETTING SPRINKLERS
12 - SECTION 3 WATER SUPPLIES
12 - 3.1 GENERAL
12 - 3.2 PROVING OF WATER SUPPLIES
12 - 3.2.1 Test facilities
12 - 3.2.2 Acceptable source of supply
12 - 3.3 CONNECTIONS TO OTHER SERVICES
12 - 3.4 FIRE BRIGADE BOOSTER CONNECTION
12 - 3.4.1 General
12 - 3.4.2 Location
13 - 3.4.3 Fittings
13 - 3.4.4 Enclosure
13 - 3.5 PRESSURE LIMITATIONS
13 - 3.6 MINIMUM CAPACITY OF RESERVOIRS AND TANKS
13 - 3.7 PRIVATE WATER SUPPLIES
13 - 3.8 TOWN MAINS
13 - 3.8.1 Direct supply from town mains
14 - 3.8.2 Pumps drawing from town mains
15 - SECTION 4 PUMPSET INSTALLATIONS
16 - SECTION 5 SYSTEM COMPONENTS
16 - 5.1 GENERAL
16 - 5.2 INSTALLATION CONTROL ASSEMBLIES
16 - 5.3 EMERGENCY INSTRUCTIONS
16 - 5.4 LOCATION PLATE
17 - SECTION 6 PIPING
18 - APPENDIX A - REFERENCED AND RELATED DOCUMENTS
18 - A1 STANDARDS
18 - A2 RELATED DOCUMENTS
19 - APPENDIX B - A METHOD OF ASSESSING THE AREA REQUIRING PROTECTION
19 - B1 SCOPE
19 - B2 RATIONALE
19 - B3 DEFINING THE FIRE WITHIN THE SOURCE BUILDING
19 - B4 DEFINING THE SOURCE OF RADIANT HEAT
19 - B4.1 General
19 - B4.2 Vertical and horizontal sources
19 - B4.3 Source radiant heat intensity
19 - B4.4 Bounding rectangle
20 - B4.5 Percentage of openings
20 - B4.6 Aspect ratio
20 - B5 THE RECEIVER BUILDING
20 - B5.1 Limiting radiant heat intensity
20 - B5.2 Attenuation factor
20 - B5.3 Limiting distance
20 - B6 ASSUMED VALUES
21 - B7 EXAMPLES
21 - B7.1 Vertical source example
22 - B7.2 Horizontal source example
25 - APPENDIX C - DISCHARGE PERFORMANCE TEST FOR WALL WETTING SPRINKLERS
25 - C1 SCOPE
25 - C2 RATIONALE
25 - C3 APPARATUS
26 - C4 SPECIMEN
27 - C5 PROGRAM OF TEST RUNS
27 - C6 TEST PROCEDURE
27 - C7 CALCULATIONS
28 - C8 TEST REPORT
31 - APPENDIX D - DETERMINATION OF THE AREA OF OPERATION
31 - D1 GENERAL
31 - D2 METHOD
31 - D3 EXAMPLE
33 - APPENDIX E - DETERMINATION OF RADIANT HEAT OPERATION CHARACTERISTICS OF SEALED WALL WETTING SPRINKLERS
33 - E1 SCOPE
33 - E2 PRINCIPLE
33 - E3 METHOD
33 - E4 APPARATUS
33 - E4.1 Radiant panel
33 - E4.2 Pipework
33 - E5 CONDITIONING
33 - E6 PREPARATION
34 - E7 PROCEDURE
34 - E8 CALCULATION
34 - E9 REPORTING OF RESULTS
35 - APPENDIX F - WIRING SYSTEMS RATING
35 - F1 PROTECTION AGAINST EXPOSURE TO FIRE
35 - F2 PROTECTION AGAINST MECHANICAL DAMAGE
36 - F3 PROTECTION AGAINST HOSING WITH WATER

Specifies minimum performance requirements of wall wetting sprinklers.

Committee
FP-004
DocumentType
Standard
ISBN
0 7262 9649 X
Pages
30
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies minimum requirements for wall wetting sprinkler systems intended to automatically provide external protection to windows, doors, and walls from exposure to fire where the anticipated radiant heat flux from a fire-source feature is 10 kW/m2or greater. It does not apply to manually-operated systems.Appendices provide methods of assessing the area requiring protection and detail a test procedure for assessment of the operating characteristics of wall wetting sprinklers when exposed to radiant heat.

First published as AS 2118.2-1995.

AS 2484.1-1990 Fire - Glossary of terms Fire tests (Reconfirmed 2016)
AS/NZS 3500.0:2003 Plumbing and drainage Glossary of terms
AS 4118.1.1-1996 Fire sprinkler systems Components - Sprinklers and sprayers (Reconfirmed 2013)
AS 3500.0-1990 National Plumbing and Drainage Code Glossary of terms
AS 2419.1-1994 Fire hydrant installations System design, installation and commissioning
AS 2118.9-1995 Automatic fire sprinkler systems Piping support and installation (Reconfirmed 2013)
AS 4118.1.3-1995 Fire sprinkler systems Components - Water motor alarms (Reconfirmed 2013)
AS 4118.1.7-1996 Fire sprinkler systems Components - Alarm valves (dry) (Reconfirmed 2013)
AS 3000-1986 Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules)
AS 1670-1986 Automatic fire detection and alarm systems - System design, installation, and commissioning
AS 3013-1990 Electrical installations - Wiring systems for specific applications
AS 4118.1.2-1996 Fire sprinkler systems Components - Alarm valves (wet) (Reconfirmed 2013)
AS 2941-2002 Fixed fire protection installations - Pumpset systems
AS 1657-1992 Fixed platforms, walkways, stairways and ladders - Design, construction and installation
AS 4118.1.5-1996 Fire sprinkler systems Components - Deluge and pre-action valves (Reconfirmed 2013)
AS 4118.2.1-1995 Fire sprinkler systems Piping - General (Reconfirmed 2013)
AS 2118.1-2006 Automatic fire sprinkler systems General systems
AS 2941-1995 Fixed fire protection installations - Pumpset systems
AS 4118.1.6-1995 Fire sprinkler systems Components - Stop valves and non-return valves (Reconfirmed 2013)
AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
AS 4118.1.4-1994 Fire sprinkler systems Components - Valve monitors (Reconfirmed 2013)
AS 2484.2-1991 Fire - Glossary of terms Fire protection and firefighting equipment
AS 2118.1-1995 Automatic fire sprinkler systems - Standard

AS/NZS 3833:2007 The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers
AS 2118.1:2017 Automatic fire sprinkler systems General systems
AS 3846-2005 The handling and transport of dangerous cargoes in port areas
SAA HB20-1996 Graphical symbols for fire protection drawings (Reconfirmed 2018)
HB 147-2000 Sprinklers Simplified
AS 2441-2005 Installation of fire hose reels (Reconfirmed 2018)
AS 4809-2003 Copper pipe and fittings - Installation and commissioning
AS/NZS 2022:2003 Anhydrous ammonia - Storage and handling (Reconfirmed 2023)
AS 2941-2008 Fixed fire protection installations - Pumpset systems
AS 2714-2008 The storage and handling of organic peroxides (Reconfirmed 2021)
AS 2118.10-1995 Automatic fire sprinkler systems Approval documentation (Reconfirmed 2013)
AS 3007.3-2004 Electrical installations - Surface mines and associated processing plant General requirements for equipment and ancillaries
AS/NZS 4681:2000 The storage and handling of Class 9 (miscellaneous) dangerous goods and articles
AS 4332-2004 The storage and handling of gases in cylinders (Reconfirmed 2016)
AS 2118.1-1995 Automatic fire sprinkler systems - Standard
AS 1851.14-1996 Maintenance of fire protection equipment - Pumpset systems
AS 2118.1-2006 Automatic fire sprinkler systems General systems
AS 1851-2005 Maintenance of Fire Protection Systems and Equipment
AS 2444-2001 Portable fire extinguishers and fire blankets - Selection and location (Reconfirmed 2021)
AS 2665-2001 Smoke/heat venting systems - Design, installation and commissioning (Reconfirmed 2016)
AS/NZS 4081:2001 The storage and handling of liquid and liquefied polyfunctional isocyanates (Reconfirmed 2021)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.