AS 2419.1-2005
AvailableSuperseded
An Available Superseded Standard is one, which has been made available for a period of time although it has been formally superseded by another Standard. Its availability is maintained where it is referenced in legislation/regulations or in other Standards and its use should be restricted to where so referenced. No responsibility is taken by SAI Global as to the ongoing technical validity of such a Standard, the responsibility resting with the referencing authority.
Fire hydrant installations System design, installation and commissioning
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
26-11-2005
Specifies requirements for the design, installation and commissioning of fire hydrants.
Committee |
FP-009
|
DocumentType |
Standard
|
ISBN |
0 7337 7010 X
|
Pages |
86
|
PublisherName |
Standards Australia
|
Status |
AvailableSuperseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
This Standard sets out requirements for the design, installation, and commissioning of fire hydrant systems to protect properties. It applies to fire hydrant systems installed to protect buildings, structures, storage yards, marinas and associated moored vessels, wharves, and plant. This Standard also applies to street fire hydrants used in lieu of on-site fire hydrants or to supplement the coverage afforded by street fire hydrants.NOTES:1 Requirements for maintenance of fire hydrant installations are given in AS1851 (see Appendix G).2 AppendixC sets out a flow chart for a fire hydrant system design based on the type and capability of the water supply.3 Hose couplings and the regions in which they are used in Australia are given in AppendixE.
Originated as AS 2419-1980.
Revised and redesignated AS 2419.1-1988.
Fourth edition 2005.
Reissued incorporating Amendment No. 1 (June 2007).
AS 1432-2004 | Copper tubes for plumbing, gasfitting and drainage applications |
AS 2118.1-2006 | Automatic fire sprinkler systems General systems |
AS/NZS 1477:2006 | PVC pipes and fittings for pressure applications |
AS/NZS 4680:2006 | Hot-dip galvanized (zinc) coatings on fabricated ferrous articles (Reconfirmed 2017) |
AS 1940-2004 | The storage and handling of flammable and combustible liquids |
AS 2638.1-2002 | Gate valves for waterworks purposes Metal seated |
AS 4041-1998 | Pressure piping |
AS 1873-1978 | Explosive-powered hand-held fastening tools, fasteners and explosive charges |
AS 1579-2001 | Arc-welded steel pipes and fittings for water and wastewater (Reconfirmed 2018) |
AS/NZS 1477:1999 | PVC pipes and fittings for pressure applications |
AS/NZS 4158:2003 | Thermal-bonded polymeric coatings on valves and fittings for water industry purposes (Reconfirmed 2015) |
AS 1345-1995 | Identification of the contents of pipes, conduits and ducts (Reconfirmed 2018) |
AS 1349-1986 | Bourdon tube pressure and vacuum gauges (Reconfirmed 2018) |
AS/NZS 1221:1997 | Fire hose reels (Reconfirmed 2020) |
AS 2638-1991 | Sluice valves for waterworks purposes |
AS 1074-1989 | Steel tubes and tubulars for ordinary service (Reconfirmed 2018) |
AS/NZS 4130:2003 | Polyethylene (PE) pipes for pressure applications |
AS 2484.2-1991 | Fire - Glossary of terms Fire protection and firefighting equipment |
AS/NZS 4792:2006 | Hot-dip galvanized (zinc) coatings on ferrous hollow sections, applied by a continuous or a specialized process (Reconfirmed 2017) |
AS 3672-1989 | Wrought steel threaded pipe fittings |
AS 1769-1975 | Welded stainless steel tubes for plumbing applications (Reconfirmed 2018) |
AS 1674-1980 | Fire precautions in cutting, heating and welding operations |
AS 4728-2005 | Electric resistance welded steel pipe for pressure purposes (Reconfirmed 2016) |
AS 3579-1993 | Cast iron wedge gate valves for general purposes |
AS 2419.3-1996 | Fire hydrant installations - Fire brigade booster connections |
AS 3962-2001 | Guidelines for design of marinas |
AS 2419.2-1994 | Fire hydrant installations Fire hydrant valves |
AS/NZS 4792:1999 | Hot-dip galvanized (zinc) coatings on ferrous hollow sections, applied by a continuous or a specialized process |
AS/NZS 1167.1:2005 | Welding and brazing - Filler metals Filler metal for brazing and braze welding |
AS 1674.2-2003 | Safety in welding and allied processes - Electrical |
AS 1572-1998 | Copper and copper alloys - Seamless tubes for engineering purposes (Reconfirmed 2018) |
AS 4809-2003 | Copper pipe and fittings - Installation and commissioning |
SAA HB20-1996 | Graphical symbols for fire protection drawings (Reconfirmed 2018) |
AS 2638.2-2002 | Gate valves for waterworks purposes - Resilient seated |
AS 2832.2-2003 | Cathodic protection of metals Compact buried structures |
AS/NZS 2312:2002 | Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings |
AS/NZS 1596:2002 | The storage and handling of LP Gas |
AS/NZS 2544:1995 | Grey iron pressure fittings |
AS 10745-1998 | Information technology - Open Systems Interconnection - Upper layers security model |
AS/NZS 3500.0:2003 | Plumbing and drainage Glossary of terms |
AS 4441(INT)-2003 | Oriented PVC (PVC-O) pipes for pressure applications |
AS 1851-2005 | Maintenance of Fire Protection Systems and Equipment |
AS/NZS 4129:2000 | Fittings for polyethylene (PE) pipes for pressure applications |
AS/NZS 2280:2004 | Ductile iron pipes and fittings |
AS 1674.1-1997 | Safety in welding and allied processes Fire precautions (Reconfirmed 2016) |
AS 1170.4-2007 | Structural design actions Earthquake actions in Australia (Reconfirmed 2018) |
HB 213:2003 | Guidelines for safe working in a confined space |
AS/NZS 3500.1:2003 | Plumbing and drainage Water services |
AS 2792-1992 | Fire hose - Delivery layflat (Reconfirmed 2017) |
AS/NZS 4765(INT):2000 | Modified PVC (PVC-M) pipes for pressure applications |
AS/NZS 2845.1:1998 | Water supply - Backflow prevention devices Materials, design and performance requirements |
AS 2941-2002 | Fixed fire protection installations - Pumpset systems |
AS/NZS 1518:2002 | External extruded high-density polyethylene coating system for pipes (Reconfirmed 2016) |
AS/NZS 4680:1999 | Hot-dip galvanized (zinc) coatings on fabricated ferrous articles |
AS 2118.1-1999 | Automatic fire sprinkler systems General requirements |
AS 2419.3-2012 | Fire hydrant installations Fire brigade booster connections |
AS/NZS 3833:2007 | The storage and handling of mixed classes of dangerous goods, in packages and intermediate bulk containers |
AS/NZS 1596:2002 | The storage and handling of LP Gas |
AS 2792-1992 | Fire hose - Delivery layflat (Reconfirmed 2017) |
AS 1851-2012 | Routine service of fire protection systems and equipment |
AS 2118.1:2017 | Automatic fire sprinkler systems General systems |
AS 1940:2017 | The storage and handling of flammable and combustible liquids |
AS 4326-2008 | The storage and handling of oxidizing agents |
AS 3961-2005 | The storage and handling of liquefied natural gas |
AS 2118.2-2010 | Automatic fire sprinkler systems Drencher systems |
AS 2419.2-1994 | Fire hydrant installations Fire hydrant valves |
AS 1894-1997 | The storage and handling of non-flammable cryogenic and refrigerated liquids (Reconfirmed 2021) |
AS 1940-2004 | The storage and handling of flammable and combustible liquids |
AS 2441-2005 | Installation of fire hose reels (Reconfirmed 2018) |
AS 4326-1995 | The storage and handling of oxidizing agents |
AS/NZS 2022:2003 | Anhydrous ammonia - Storage and handling (Reconfirmed 2023) |
AS 2118.6-1995 | Automatic fire sprinkler systems - Combined sprinkler and hydrant |
AS 2118.4-2012 | Automatic fire sprinkler systems Sprinkler protection for accommodation buildings not exceeding four storeys in height |
HB 37.4-1994 | Handbook of Australian fire Standards Building materials, products and construction (Reconfirmed 2016) |
AS 3772-1990 | Fire protection of cooking areas |
AS 2419.2-2009 | Fire hydrant installations Fire hydrant valves |
AS 5124:2017 | Safety of machinery - Equipment for power driven parking of motor vehicles - Safety and EMC requirements for design, manufacturing, erection and commissioning stages (EN 14010:2003, MOD) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 2941-2013 | Fixed fire protection installations - Pumpset systems |
AS 4332-2004 | The storage and handling of gases in cylinders (Reconfirmed 2016) |
AS 4809:2017 | Copper pipe and fittings - Installation and commissioning |
AS 2118.6-2012 | Automatic fire sprinkler systems Combined sprinkler and hydrant systems in multistorey buildings |
AS/NZS 1596:2008 | The storage and handling of LP Gas |
AS/NZS 2927:2001 | The storage and handling of liquefied chlorine gas |
AS 4825-2011 | Tunnel fire safety |
AS 2118.1-2006 | Automatic fire sprinkler systems General systems |
AS/NZS 3500.1:2003 | Plumbing and drainage Water services |
AS/NZS 4081:2001 | The storage and handling of liquid and liquefied polyfunctional isocyanates (Reconfirmed 2021) |
AS 2304-2011 | Water storage tanks for fire protection systems |
AS 2419.3-1996 | Fire hydrant installations - Fire brigade booster connections |
AS/NZS 1596:2014 | The storage and handling of LP Gas |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.