AS 2676.2-1992
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Sealed cells
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
17-04-2020
English
01-01-1992
Part 2 sets out recommended practices for the installation, maintenance, testing and replacement of sealed secondary batteries permanently installed in buildings.
Committee |
EL-005
|
DocumentType |
Standard
|
ISBN |
0 7262 7302 3
|
Pages |
28
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
This Standard sets out recommended practices for the installation, maintenance, testing and replacement of sealed secondary batteries (either valve-regulated or gastight) located in or on buildings. It also provides guidance to determine when batteries should be replaced.This Standard covers secondary batteries with a nominal voltage of 24 V or greater, and a capacity exceeding 10 A.h at the 1 h rate and includes batteries comprising lead-acid cells and alkaline cells (such as nickel-cadmium cells).This Standard covers requirements for components of the d.c. system of which the battery is a part, wherethese components comprise an essential part of the d.c. system.This Standard covers sealed cells only. The installation and maintenance of vented cells are covered byAS 3011.1 and AS 2676.1.NOTE: Requirements specifically applicable to the design and installation of extra-low voltage (d.c.) power supplies that are used by telecommunications carriers in the provision of public telecommunications networks are given in AS 3015 (Int)-1991, Electrical installations- Extra-low voltage (d.c.) power supplies in public telecommunications networks.
First published as AS 2676.2-1992.
AS 2121-1979 | The design of earthquake-resistant buildings (known as the SAA Earthquake Code) |
AS/NZS 1680.1:2006 | Interior and workplace lighting General principles and recommendations |
AS 1775-1984 | Low voltage switchgear and controlgear - Air-break switches, isolators and fuse-combination units (up to and including 1000 V a.c. and 1200 V d.c.) |
AS 1136.1-1988 | Low voltage switchgear and controlgear assemblies General requirements |
AS 3000-1986 | Electrical installations - Buildings, structures and premises (known as the SAA Wiring Rules) |
AS 1680.1-1990 | Interior lighting General principles and recommendations |
AS 3111-1994 | Approval and test specification - Miniature overcurrent circuit-breakers |
AS 2184-1985 | Low voltage switchgear and controlgear - Moulded-case circuit-breakers for rated voltages up to and including 600 V a.c. and 250 V d.c. |
AS 3011.1-1992 | Electrical installations - Secondary batteries installed in buildings - Vented cells Vented cells |
AS 2676.1-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells |
AS 1319-1994 | Safety signs for the occupational environment (Reconfirmed 2018) |
AS 3011.2-1992 | Electrical installations - Secondary batteries installed in buildings Sealed cells |
AS 3015-1993 | Electrical installations - Extra-low voltage d.c. power supplies within public telecommunications networks |
AS/NZS 2982:2010 | Laboratory design and construction |
AS 3011.2:2019 | Electrical installations - Secondary batteries installed in buildings Sealed cells |
AS/NZS 3015:2004 | Electrical installations - Extra-low voltage d.c. power supplies and service earthing within public telecommunications networks |
AS 3011.2-1992 | Electrical installations - Secondary batteries installed in buildings Sealed cells |
AS/NZS 3010:2017 | Electrical installations - Generating sets |
AS/NZS 2293.2:2019 | Emergency lighting and exit signs for buildings Routine service and maintenance |
AS/NZS 4836:2011 | Safe working on or near low-voltage electrical installations and equipment |
AS/NZS 4836:2001 | Safe working on low-voltage electrical installations |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS 3011.1-1992 | Electrical installations - Secondary batteries installed in buildings - Vented cells Vented cells |
HB 94-1997 | Electrical safety in the workplace |
AS 1851.6-1997 | Maintenance of fire protection equipment - Management procedures for maintaining the fire and smoke control features of air-handling systems |
AS 2067-2008 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 4991-2004 | Lifting devices |
AS 2676.1:2020 | Installation, maintenance, testing and replacement of secondary batteries in buildings Vented cells |
AS/NZS 2293.2:1995 | Emergency escape lighting and exit signs for buildings Inspection and maintenance |
AS/NZS 3010:2005 | Electrical installations - Generating sets |
AS/NZS 2381.1:2005 | Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance General requirements |
AS 3015(INT)-1991 | Electrical installations - Extra-low voltage (d.c.) power supplies in public telecommunications networks |
AS 2293.1-2005 | Emergency escape lighting and exit signs for buildings System design, installation and operation |
AS 4509.2-2002 | Stand-alone power systems - System design guidelines |
AS/NZS 2201.1:2007 | Intruder alarm systems Client’s premises - Design, installation, commissioning and maintenance |
AS 3011.1:2019 | Electrical installations - Secondary batteries installed in buildings Vented cells |
AS 2067:2016 | Substations and high voltage installations exceeding 1 kV a.c. |
AS 1851.14-1996 | Maintenance of fire protection equipment - Pumpset systems |
AS 2201.2-2004 | Intruder alarm systems Monitoring centres |
AS 1670.4-2004 | Fire detection, warning, control and intercom systems - System design, installation and commissioning Sound systems and intercom systems for emergency purposes |
AS 2676.1-1992 | Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings - Vented cells |
AS/NZS 2293.1:1995 | Emergency evacuation lighting for buildings System design, installation and operation |
AS/NZS 60079.14:2009 | Explosive atmospheres Electrical installations design, selection and erection (IEC 60079-14, Ed. 4.0 (2007) MOD) |
AS 4086.2-1997 | Secondary batteries for use with stand-alone power systems Installation and maintenance |
AS/NZS 2293.1:1998 | Emergency evacuation lighting for buildings System design, installation and operation |
AS/NZS 2293.1:2018 | Emergency lighting and exit signs for buildings System design, installation and operation |
AS 1668.2-2012 | The use of ventilation and airconditioning in buildings Mechanical ventilation in buildings |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.