AS/NZS 3120:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Approval and test specification - Cord extension sockets

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

29-05-2024

Superseded by

AS/NZS 3120:2011

Language(s)

English

Published date

01-01-1999

€45.79
Excluding VAT

1 - AS/NZS 3120:1999 APPROVAL AND TEST SPECIFICATION-CORD EXTENSION SOCKETS
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 APPLICATION
6 - 2.1 General requirements of AS/NZS 3100
6 - 2.2 Specific requirements of this Standard
6 - 3 REFERENCED DOCUMENTS
6 - 4 DEFINITION
7 - 5 EXEMPTIONS FOR EXTRA-LOW VOLTAGE SOCKETS
7 - 6 LIMITATION OF OUTLETS
7 - 7 TERMINALS AND INTERNAL CONNECTIONS
7 - 7.1 Material
7 - 7.2 Construction of terminals
7 - 8 CONTACTS
7 - 8.1 Material
7 - 8.2 Construction
7 - 8.3 Depth of contacts
8 - 9 DIMENSIONS
8 - 9.1 Pin entry apertures for flat-pin plugs
8 - 9.2 Socket face projection
8 - 9.2.1 Socket face of sockets rated at 10 A
8 - 9.2.2 Configurations covered
9 - 9.3 Socket face of sockets rated at 15 A
9 - 10 ARRANGEMENT OF EARTHING CONNECTIONS
9 - 11 INSULATING MATERIALS
9 - 12 ATTACHMENT OF COVERS
9 - 13 EXTERNAL SHAPE
9 - 13.1 General
9 - 13.1.1 10 A and 15 A sockets with 360° projection
9 - 13.1.2 15 A without a 360° projection and 20 A sockets
10 - 13.2 Pendant type sockets
10 - 13.3 Other than pendant type sockets
10 - 13.4 Finger grip
10 - 14 EXPOSED METAL
10 - 15 MEANS OF ENTRY AND CORD ANCHORAGE FOR FLEXIBLE CORD
11 - 16 RATINGS
11 - 16.1 Voltage rating
11 - 16.2 Current rating
11 - 17 INTERNAL CONNECTIONS
11 - 18 PREVENTION OF CONTACT WITH LIVE PINS
11 - 18.1 Assembly
11 - 18.2 During normal insertion
12 - 18.3 During other than normal insertion
12 - 19 FUSES
12 - 20 SWITCHES
12 - 21 MARKING
12 - 21.1 Required marking
13 - 21.2 Location of marking
13 - 21.3 Additional requirements for rewirable sockets
13 - 21.4 Earthing connections
13 - 21.5 Live connections
13 - 21.5.1 General
13 - 21.5.2 Location of marking
13 - 21.6 Configuration of sockets intended for flat-pin plugs
13 - 22 TESTS
13 - 22.1 General
14 - 22.2 Withdrawal force test
15 - 22.3 Tumbling barrel test
15 - 22.4 Insulation resistance test No. 1
15 - 22.5 High voltage test
16 - 22.6 Current breaking test
16 - 22.7 Test of temperature rise
17 - 22.8 Insulation resistance test No. 2
17 - 22.9 Flexible cord anchorage test
17 - 22.10 Test of earthing connection
18 - 22.11 Test for attachment of covers
18 - 22.12 Test for the fixing of contacts in resilient or thermoplastic sockets
18 - 22.13 Additional tests for non-rewirable sockets

Specifies essential safety requirements for cord extension sockets intended to be used at extra-low and low voltages. This Standard is to be read in conjunction with AS/NZS 3100.

Committee
EL-004
DocumentType
Standard
ISBN
0 7337 2685 2
Pages
13
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out essential safety requirements for cord extension sockets, as defined in Clause 4, intended for use at extra-low or low voltages.This Standard does not apply to cord extension sockets which are enclosed within an appliance in such a way that they are not exposed to personal contact, or which are intended for use solely where they will be so enclosed.

First published in Australia as AS C120-1938.
Redated 1947.
Redated 1950.
Redated 1951.
Redated 1954.
Redated 1964.
Revised and redesignated AS 3120-1981.
Second edition 1987.
Third edition 1990.
Jointly revised and redesignated AS/NZS 3120:1993.
Fifth edition 1999.

AS/NZS 3350.1:2002 Safety of household and similar electrical appliances General requirements (IEC 60335-1:1991, MOD)
AS/NZS 3100:1997 Approval and test specification - General requirements for electrical equipment
AS/NZS 3112:1993 Approval and test specification - Plugs and socket-outlets
AS/NZS 3133:2003 Approval and test specification - Air break switches
AS/NZS 3100:2002 Approval and test specification - General requirements for electrical equipment
AS/NZS 3109.1:1996
AS/NZS 3112:2004 Approval and test specification - Plugs and socket-outlets
AS/NZS 3350.1:1994 Safety of household and similar electrical appliances General requirements
AS/NZS 3121:2002 Approval and test specification - Insulating mouldings (Reconfirmed 2020)
AS/NZS 3123:2005 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application (Reconfirmed 2016)
AS/NZS 3123:1994 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application

AS/NZS 3001:2001 Electrical installations - Relocatable premises (including caravans and tents) and their site installations
AS/NZS 3105:2007 Approval and test specification - Electrical portable outlet devices
AS/NZS 3012:2010 Electrical installations - Construction and demolition sites
AS/NZS 3108:1994 Approval and test specification - Particular requirements for isolating transformers and safety isolating transformers
AS/NZS 3122:2005 Approval and test specification - Socket-outlet adaptors
AS/NZS 3105:2002 Approval and test specification - Electrical portable outlet devices
AS/NZS 3109.1:1996
AS/NZS 3131:1995 Approval and test specification - Plugs and socket-outlets for use in installation wiring systems
AS/NZS 3002:2008 Electrical installations - Shows and carnivals
AS/NZS 61535.1(INT):2001 Installation couplers General requirements
AS/NZS 3190:2002 Approval and test specification - Residual current devices (current-operated earth-leakage devices)
AS/NZS 3131:2001 Approval and test specification - Plugs and socket-outlets for stationary appliances
AS/NZS 3197:2005 Approval and test specification - Portable electrical control or conditioning devices
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS/NZS 3199:2007 Approval and test specification - Cord extension sets
AS/NZS 3003:2011 Electrical installations - Patient areas
AS/NZS 3197:1993 Approval and test specification - Portable electrical control or conditioning devices
AS/NZS 4763:2011 Safety of portable inverters (Reconfirmed 2024)
AS/NZS 3190:2009 Approval and test specification - Residual current devices (current-operated earth-leakage devices)
AS/NZS 3002:2002 Electrical installations - Shows and carnivals
AS/NZS 61535.1:2003 Installation couplers General requirements
AS/NZS 3004.1:2008 Electrical installations - Marinas and recreational boats Marinas
AS/NZS 3105:1998 Approval and test specification - Electrical portable outlet devices
AS/NZS 3001:2008 Electrical installations - Transportable structures and vehicles including their site supplies
AS/NZS 3156:1995 Approval and test specification - Electric lawnmowers
AS/NZS 3004:2002 Electrical installations - Marinas and pleasure craft at low-voltage
AS/NZS 3012:2003 Electrical installations - Construction and demolition sites
AS/NZS 60320.1:2004 Appliance couplers for household and similar general purposes General requirements (IEC 60320-1, Ed. 2.0 (2001) MOD)
AS 3190-1994 Approval and test specification - Residual current devices (current-operated earth-leakage devices)
AS/NZS 4763(INT):2006 Safety of Portable Inverters
AS/NZS 60320.2.2:2004 Appliance couplers for household and similar general purposes Interconnection couplers for household and similar equipment (IEC 60320-2-2, Ed. 2.0 (1998) MOD) (Reconfirmed 2016)
AS/NZS 3122:1993 Approval and test specification - Socket-outlet adaptors
AS/NZS 3199:2000 Approval and test specification for cord extension sets - Cord extension sets
SAA HB37.2-1993 Handbook of Australian fire Standards Electrical equipment (Reconfirmed 2016)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.