AS/NZS IEC 60092.376:2020
Current
The latest, up-to-date edition.
Electrical installations in ships Cables for control and instrumentation circuits 150/250 V (300 V)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
24-01-2020
The objective of this Standard is to specify requirements for screened and unscreened cables for control and instrumentation circuits on ships and offshore units. The cables have extruded solid insulation with a voltage rating of 150/250V (300V) and are intended for fixed installations.
Committee |
EL-003
|
DocumentType |
Standard
|
ISBN |
978 1 76072 705 5
|
Pages |
19
|
PublisherName |
Standards Australia
|
Status |
Current
|
Supersedes |
This part of IEC 60092 is applicable to screened and unscreened cables for control and instrumentation circuits on ships and offshore units. The cables have extruded solid insulation with a voltage rating of 150/250V (300V) (see Clause 4) and are intended for fixed installations.
The various types of cables are given in Clause 5. The constructional requirements and test methods are aligned with those indicated in IEC 60092-350, unless otherwise specified in this document.
The object of this document is
– to standardise cables whose safety and reliability are ensured when they are installed in accordance with the requirements of IEC 60092-352,
– to lay down standard manufacturing requirements and characteristics of such cables directly or indirectly bearing on safety, and
– to specify test methods for checking conformity with those requirements.
Standards | Relationship |
IEC 60092-376:2017 | Identical |
First published as AS 60092.376-2005.
Jointly revised and redesignated as AS/NZS IEC 60092.376:2020.
IEC 61034-1:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
IEC 60092-354:2014 | Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
IEC 60092-353:2016 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 60331-11:1999+AMD1:2009 CSV | Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 °C |
IEC 60331-21:1999 | Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
IEC 60092-352:2005 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
IEC 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60038:2009 | IEC standard voltages |
IEC 60332-3-22:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A |
IEC 60092-350:2014 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
IEC 60331-1:2018 RLV | Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm |
IEC 60331-2:2018 RLV | Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20mm |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.