BS 9999:2017
Current
The latest, up-to-date edition.
Fire safety in the design, management and use of buildings. Code of practice
Hardcopy , PDF
English
28-02-2017
Foreword
Section 1: General
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General recommendations and background
Section 2: Risk profiles and assessing risk
5 Assessing risk
6 Risk profiles
Section 3: Ensuring effective fire protection
7 Ensuring effective fire protection
Section 4: Designing for the management of fire risk
8 Establishing fire risk management systems
9 Fire safety documentation
10 Designing so that a building can be managed
Section 5: Designing means of escape
11 Principles of means of escape
12 Evacuation strategy
13 Internal subdivision and spatial/visual orientation
14 Designing means of escape
15 Minimum package of fire protection
16 Horizontal means of escape
17 Vertical means of escape
18 Additional fire protection measures
Section 6: Access and facilities for fire-fighting
19 General recommendations for fire-fighting facilities
20 Facilities for fire-fighting
21 Vehicle access
22 Water supplies for fire and rescue service use
23 Communications systems for fire and rescue service
use
24 Fire control centre
25 Fire-fighters emergency switches for discharge
lighting installation
26 Drawings for fire and rescue service use
27 Heat and smoke control
28 Electrical services
Section 7: Designing the building structure (load-bearing
and non-load-bearing elements)
29 Designing the building structure - General
30 Fire resistance
31 Compartmentation
32 Openings
33 Concealed spaces
34 Materials and finishes
35 External fire spread and building separation
36 Accommodation ancillary to the main use of the
building
37 Engineering services
Section 8: Special risk protection
38 Special risk protection
Section 9: Managing occupied buildings
39 Commissioning and handover
40 Managing occupied buildings
41 Fire prevention
42 Ensuring that systems respond properly in an
emergency
43 Planning the response to a fire
44 Emergency actions
45 Evacuation of disabled people
46 Management of fire safety prior to full occupation
of a building
47 Building works, alterations, decommissioning
and demolition
Annexes
Annex A (normative) - Additional recommendations for
property protection and business continuity
Annex B (normative) - Recommendations for atria
Annex C (informative) - Design solutions and exemplars
for atria
Annex D (normative) - Recommendations for theatres,
cinemas and similar venues
Annex E (normative) - Recommendations for shopping
complexes
Annex F (normative) - Process plant and outdoor
structures
Annex G (normative) - Recommendations for refuges
and evacuation lifts
Annex H (normative) - Fire safety manual
Annex I (normative) - Routine inspection and maintenance
of fire safety installations
Annex J (normative) - Fire control centre and evacuation
management
Annex K (informative) - Fire safety equipment, facilities
and systems
Annex L (informative) - Signs and signage
Annex M (normative) - Phased evacuation
Annex N (informative) - Typical arrangements to keep
firefighters lift wells free from water
Annex O (normative) - Operational information (emergency
packs) for the fire and rescue service
Annex P (normative) - Commissioning and handover
of smoke control systems
Annex Q (normative) - Fire safety training
Annex R (normative) - Control of conditions in public
areas
Annex S (normative) - Recommendations for owners
of multi-occupancy residential buildings
Annex T (informative) - Examples of fire instruction
notice text
Annex U (normative) - Audience/crowd control
Annex V (normative) - Hot work
Annex W (normative) - Routine inspection and maintenance
of ventilation and air conditioning ductwork
Annex X (informative) - Examples of evacuation strategies
Bibliography
Index
Provides recommendations and guidance on the design, management and use of buildings to achieve reasonable standards of fire safety for all people in and around buildings.
Committee |
FSH/14
|
DevelopmentNote |
Supersedes 16/30314117 DC and BS 9999(2008). (01/2017)
|
DocumentType |
Standard
|
ISBN |
9780580977169
|
Pages |
418
|
ProductNote |
C1. Correction to Table 24
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This British Standard gives recommendations and guidance on the design, management and use of buildings to achieve reasonable standards of fire safety for all people in and around buildings. This British Standard is not applicable to the following types of building, which are covered in BS9991: dwellings (single-family dwelling houses, self-contained flats or maisonettes); residential accommodation blocks (e.g. for students or hospital staff), with individual bedrooms and the provision of kitchen/sanitary facilities constructed within a fire compartment; specialized housing. It is not applicable to houses of multiple occupancy (HMOs) or buildings in which occupants receive medical care. It might have only limited applicability to certain specialist buildings and areas of buildings (e.g. areas of lawful detention). This British Standard is applicable to the design of new buildings, and to material alterations, extensions and material change of use of an existing building. NOTE Attention is drawn to the Building Regulations 2010 [1] and equivalent national variations ([3] to [5]) in respect of the definition of material alterations, extensions and material change of use. It also provides recommendations and guidance on the ongoing management of fire safety in a building throughout the entire life cycle of the building, including measures for designers to ensure that the overall design of a building assists and enhances the management of fire safety. It can be used as a tool for assessing existing buildings, although fundamental change in line with its recommendations might be limited or not practicable. The recommendations and guidance given in this British Standard are intended to safeguard the lives of building occupants and fire-fighters. Whilst some of the recommendations and guidance might also assist in the achievement of other fire safety objectives – such as protection of property, the environment, communities and business/service viability – additional measures might be necessary which are outside the scope of this British Standard. This British Standard does not cover fire safety design strategies for extreme events such as terrorist actions.
17/30351608 DC : 0 | BS 5410-2 - CODE OF PRACTICE FOR OIL FIRING - PART 2: INSTALLATIONS PROVIDING SPACE HEATING, HOT WATER AND STEAM SUPPLY SERVICES TO NON-DOMESTIC BUILDINGS |
BS 8203:2017 | Code of practice for installation of resilient floor coverings |
BS 8297:2017 | Design, manufacture and installation of architectural precast concrete cladding. Code of practice |
BS 5839-1:2017 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
17/30367827 DC : 0 | BS 8486-8 - EXAMINATION AND TEST OF NEW LIFTS BEFORE PUTTING INTO SERVICE - SPECIFICATION FOR MEANS OF DETERMINING COMPLIANCE WITH BS EN 81 - PART 8: LIFT FEATURES FOR FIRE-FIGHTING CONFORMING TO BS EN 81-72 |
17/30335800 DC : 0 | BS 8300-1 - DESIGN OF AN ACCESSIBLE AND INCLUSIVE BUILT ENVIRONMENT - PART 1: EXTERNAL ENVIRONMENT - CODE OF PRACTICE |
17/30354416 DC : DRAFT AUG 2017 | BS 8572 - PROCUREMENT OF FACILITY-RELATED SERVICES - CODE OF PRACTICE |
17/30335834 DC : 0 | BS 8300-2 - DESIGN OF AN ACCESSIBLE AND INCLUSIVE BUILT ENVIRONMENT - PART 2: BUILDINGS - CODE OF PRACTICE |
ENA ER G87 : ISSUE 2 2015 | GUIDELINES FOR THE PROVISION OF LOW VOLTAGE CONNECTIONS TO MULTIPLE OCCUPANCY BUILDINGS |
17/30342957 DC : 0 | BS 8297 - DESIGN, MANUFACTURE AND INSTALLATION OF ARCHITECTURAL PRECAST CONCRETE CLADDING - CODE OF PRACTICE |
BS 8300-1:2018 | Design of an accessible and inclusive built environment External environment. Code of practice |
17/30344477 DC : 0 | BS 8606 - ADULT CARE SERVICES - CODE OF PRACTICE |
I.S. 3218:2013+A1:2019 | Fire detection and alarm systems for buildings - System design, installation, commissioning, servicing and maintenance & Amendment 1:2019 |
BS 7036-0:2014 | Power operated pedestrian doorsets. Safety in use Code of practice for risk assessment and risk reduction |
93/68/EEC : 1993 AMD 2 1998 | COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC |
BS PAS 7(2013) : 2013 | FIRE RISK MANAGEMENT SYSTEM - SPECIFICATION |
BS EN 54-23:2010 | Fire detection and fire alarm systems Fire alarm devices. Visual alarm devices |
BS 5410-2:2013 | Code of practice for oil firing Installations over 45 kW output capacity for space heating, hot water and steam supply services |
BS EN 115-1:2017 | Safety of escalators and moving walks Construction and installation |
BS EN 1021-1:2014 | Furniture. Assessment of the ignitability of upholstered furniture Ignition source smouldering cigarette |
BS 7346-4:2003 | Components for smoke and heat control systems Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing steady-state design fires. Code of practice |
BS EN 54-27:2015 | Fire detection and fire alarms systems Duct smoke detectors |
BS EN ISO 12543-2:2011 | Glass in building. Laminated glass and laminated safety glass Laminated safety glass |
BS 8486-1(2007) : 2007 | EXAMINATION AND TEST OF NEW LIFTS BEFORE PUTTING INTO SERVICE - SPECIFICATION FOR MEANS OF DETERMINING COMPLIANCE WITH BS EN 81 - PART 1: ELECTRIC LIFTS |
BS 8899:2016 | Improvement of fire-fighting and evacuation provisions in existing lifts. Code of practice |
BS 5656-2:2004 | Escalator and moving walks. Safety rules for the construction and installation of escalators and moving walks Code of practice for the selection, installation and location of new escalators and moving walks |
BS 6187:2011 | Code of practice for full and partial demolition |
BS EN 1366-7:2004 | Fire resistance tests for service installations Conveyor systems and their closures |
BS EN 50272-1:2010 | Safety requirements for secondary batteries and battery installations General safety information |
BS EN 81-71:2005 | Safety rules for the construction and installation of lifts. Particular applications to passenger lifts and goods passenger lifts Vandal resistant lifts |
BS 5306-3:2009 | Fire extinguishing installations and equipment on premises Commissioning and maintenance of portable fire extinguishers. Code of practice |
CEN/CLC Guide 6:2014 | Guide for addressing accessibility in standards |
BS EN 1155:1997 | Building hardware. Electrically powered hold-open devices for swing doors. Requirements and test methods |
BS 5656-1:2013 | Safety rules for the construction and installation of escalators and moving walks Examination and test of new escalators before putting into service. Specification for means of determining compliance with BS EN 115-1:2008+A1:2010 |
BS 25999-1:2006 | BUSINESS CONTINUITY MANAGEMENT - PART 1: CODE OF PRACTICE |
BS EN ISO 13943:2017 | Fire safety. Vocabulary |
BS 7273-4:2015 | Code of practice for the operation of fire protection measures Actuation of release mechanisms for doors |
BS 5516-2:2004 | Patent glazing and sloping glazing for buildings Code of practice for sloping glazing |
BS 5839-1:2013 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
BS EN 81-58:2003 | Safety rules for the construction and installation of lifts Examination and tests. Landing doors fire resistance test |
BS 8486-2(2007) : 2007 | EXAMINATION AND TEST OF NEW LIFTS BEFORE PUTTING INTO SERVICE - SPECIFICATION FOR MEANS OF DETERMINING COMPLIANCE WITH BS EN 81 - PART 2: HYDRAULIC LIFTS |
BS EN 1991-1-2:2002 | Eurocode 1. Actions on structures General actions. Actions on structures exposed to fire |
BS 5839-9:2011 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems |
PD 6520:1988 | Guide to fire test methods for building materials and elements of construction |
BS EN 1125:2008 | Building hardware. Panic exit devices operated by a horizontal bar, for use on escape routes. Requirements and test methods |
BS 6262-4:2005 | Glazing for buildings Code of practice for safety related to human impact |
BS EN ISO/IEC 17021-1:2015 | Conformity assessment. Requirements for bodies providing audit and certification of management systems Requirements |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS EN 1021-2:2014 | Furniture. Assessment of the ignitability of upholstered furniture Ignition source match flame equivalent |
BS 7346-7:2013 | Components for smoke and heat control systems Code of practice on functional recommendations and calculation methods for smoke and heat control systems for covered car parks |
BS 5852:2006 | Methods of test for assessment of the ignitability of upholstered seating by smouldering and flaming ignition sources |
BS EN ISO 1182:2010 | Reaction to fire tests for products. Non-combustibility test |
BS 9990:2015 | Non automatic fire-fighting systems in buildings. Code of practice |
BS ISO 3864-1:2011 | Graphical symbols. Safety colours and safety signs Design principles for safety signs and safety markings |
BS EN 115-2:2010 | Safety of escalators and moving walks Rules for the improvement of safety of existing escalators and moving walks |
BS 5651:1978 | Cleansing and wetting procedures for use in the assessment of the effect of cleansing and wetting on the flammability of textile fabrics and fabric assemblies |
BS EN 81-72:2015 | Safety rules for the construction and installation of lifts. Particular applications for passenger and goods passenger lifts Firefighters lifts |
BS 8489-1:2016 | Fixed fire protection systems. Industrial and commercial watermist systems Code of practice for design and installation |
BS EN 81-20:2014 | Safety rules for the construction and installation of lifts. Lifts for the transport of persons and goods Passenger and goods passenger lifts |
BS EN ISO 14122-4:2016 | Safety of machinery. Permanent means of access to machinery Fixed ladders |
DD CEN/TS 14816:2008 | Fixed firefighting systems. Water spray systems. Design and installation |
BS 7346-8:2013 | Components for smoke control systems Code of practice for planning, design, installation, commissioning and maintenance |
BS EN 15650:2010 | Ventilation for buildings. Fire dampers |
BS EN 12845:2015 | Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance |
BS 5438:1989 | Methods of test for flammability of textile fabrics when subjected to a small igniting flame applied to the face or bottom edge of vertically oriented specimens |
BS EN 13565-2:2009 | Fixed firefighting systems. Foam systems Design, construction and maintenance |
BS EN 81-70:2003 | Safety rules for the construction and installation of lifts Particular applications for passenger and goods passenger lifts. Accessibility to lifts for persons including persons with disability |
BS 8519:2010 | Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. Code of practice |
BS 5839-3:1988 | Fire detection and alarm systems for buildings Specification for automatic release mechanisms for certain fire protection equipment |
BS 7157:1989 | Method of test for ignitability of fabrics used in the construction of large tented structures |
BS EN ISO 1716:2010 | Reaction to fire tests for products. Determination of the gross heat of combustion (calorific value) |
PD 7974-7:2003 | Application of fire safety engineering principles to the design of buildings Probabilistic risk assessment |
BS 5395-2:1984 | Stairs, ladders and walkways Code of practice for the design of helical and spiral stairs |
BS EN 16005:2012 | Power operated pedestrian doorsets. Safety in use. Requirements and test methods |
BS EN 13823 : 2010 | REACTION TO FIRE TESTS FOR BUILDING PRODUCTS - BUILDING PRODUCTS EXCLUDING FLOORINGS EXPOSED TO THE THERMAL ATTACK BY A SINGLE BURNING ITEM |
PD 7974-6:2004 | The application of fire safety engineering principles to fire safety design of buildings Human factors. Life safety strategies. Occupant evacuation, behaviour and condition (Sub-system 6) |
PD 7974-1:2003 | Application of fire safety engineering principles to the design of buildings Initiation and development of fire within the enclosure of origin (Sub-system 1) |
BS 7974:2001 | Application of fire safety engineering principles to the design of buildings. Code of practice |
BS EN ISO 19011:2011 | Guidelines for auditing management systems |
BS 3251:1976 | Specification. Indicator plates for fire hydrants and emergency water supplies |
BS 4422:2005 | Fire. Vocabulary |
BS EN 179:2008 | Building hardware. Emergency exit devices operated by a lever handle or push pad, for use on escape routes. Requirements and test methods |
BS EN 1154:1997 | Building hardware. Controlled door closing devices. Requirements and test methods |
BS EN 1838:2013 | Lighting applications. Emergency lighting |
BS 5306-8:2012 | Fire extinguishing installations and equipment on premises Selection and positioning of portable fire extinguishers. Code of practice |
BS EN 12416-2:2001 | Fixed firefighting systems. Powder systems Design, construction and maintenance |
BS 5499-10:2014 | Guidance for the selection and use of safety signs and fire safety notices |
BS 5656-3:2014 | Safety rules for the construction and installation of escalators and moving walks Examination and test of new moving walks before putting into service. Specification for means of determining compliance with BS EN 115-1:2008+A1:2010 |
BS EN 54-11:2001 | Fire detection and fire alarm systems Manual call points |
BS EN 1993-1-2:2005 | Eurocode 3. Design of steel structures General rules - Structural fire design |
BS EN ISO 306:2013 | Plastics. Thermoplastic materials. Determination of Vicat softening temperature (VST) |
BS EN 81-73:2016 | Safety rules for the construction and installation of lifts. Particular applications for passenger and goods passenger lifts Behaviour of lifts in the event of fire |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.