BS EN 54-23:2010
Current
The latest, up-to-date edition.
Fire detection and fire alarm systems Fire alarm devices. Visual alarm devices
Hardcopy , PDF
English
31-05-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Tests and evaluation methods
6 Evaluation of conformity
Annex A (normative) - Method for measuring the light
distribution from a VAD
Annex B (normative) - Comparative light output level
measurement for VADs
Annex C (informative) - Construction of the light test
chamber and associated equipment for comparative
measurements
Annex D (informative) - Comparison of flammability test
requirements in various standards
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Directive (89/106/EEC)
Bibliography
Describes the requirements, test methods and performance criteria for visual alarm devices in a fixed installation intended to signal a visual warning of a fire between the fire detection and fire alarm system and the occupants of a building.
Committee |
FSH/12/5
|
DevelopmentNote |
Supersedes 04/30109635 DC. (05/2010)
|
DocumentType |
Standard
|
Pages |
70
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN 54-23:2010 | Identical |
BS 5839-6:2013 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises |
BS 5839-1:2017 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
BS 5839-9:2011 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems |
14/30277275 DC : 0 | BS 5446-3 - FIRE DETECTION AND FIRE ALARM DEVICES FOR DWELLINGS - PART 3: SPECIFICATION FOR FIRE AND CARBON MONOXIDE ALARM SYSTEMS FOR DEAF AND HARD OF HEARING PEOPLE |
12/30260278 DC : 0 | BS 5839-1 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 1: CODE OF PRACTICE FOR DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE |
07/30136498 DC : 0 | BS 5839-8 - FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - PART 8: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND SERVICING OF VOICE ALARM SYSTEMS |
BS 5839-8:2013 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation, commissioning and maintenance of voice alarm systems |
12/30258581 DC : 0 | BS 5908-2 - FIRE AND EXPLOSION PRECAUTIONS AT PREMISES HANDLING FLAMMABLE GASES, LIQUIDS AND DUSTS - PART 2: GUIDE TO APPLICABLE STANDARDS AND REGULATIONS |
BS 5839-1:2013 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
BS 5908-2:2012 | Fire and explosion precautions at premises handling flammable gases, liquids and dusts Guide to applicable standards and regulations |
12/30258718 DC : 0 | BS 5839-8 - FIRE DETECTION AND FIRE ALARM SYSTEMS FOR BUILDINGS - PART 8: CODE OF PRACTICE FOR THE DESIGN, INSTALLATION, COMMISSIONING AND MAINTENANCE OF VOICE ALARM SYSTEMS |
BS 9999:2017 | Fire safety in the design, management and use of buildings. Code of practice |
BS 5446-3:2015 | Detection and alarm devices for dwellings Specification for fire alarm and carbon monoxide alarm systems for deaf and hard of hearing people |
93/68/EEC : 1993 AMD 2 1998 | COUNCIL DIRECTIVE 93/68/EEC OF 22.7.93 AMENDING DIRECTIVES 87/404/EEC, 88/378/EEC, 89/106/EEC, 89/336/EEC, 89/392/EEC, 89/686/EEC, 90/384/EEC, 90/385/EEC, 90/396/EEC, 91/263/EEC, 92/42/EEC AND 73/23/EEC |
IEC 60695-11-20:2015 | Fire hazard testing - Part 11-20: Test flames - 500 W flame test method |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
89/106/EEC : 1988 | COUNCIL DIRECTIVE OF 21 DECEMBER 1988 ON THE APPROXIMATION OF LAWS, REGULATIONS AND ADMINISTRATIVE PROVISIONS OF THE MEMBER STATES RELATING TO CONSTRUCTION PRODUCTS |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
ISO 23539:2005 | Photometry — The CIE system of physical photometry |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
ISO 9001:2015 | Quality management systems — Requirements |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 50130-4:2011/A1:2014 | ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN 54-1:2011 | Fire detection and fire alarm systems - Part 1: Introduction |
ISO 2813:2014 | Paints and varnishes — Determination of gloss value at 20°, 60° and 85° |
EN ISO 2813:2014 | Paints and varnishes - Determination of gloss value at 20°, 60° and 85° (ISO 2813:2014) |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-