BS EN 61007:1997
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Transformers and inductors for use in electronic and telecommunication equipment. Measuring methods and test procedures
Hardcopy , PDF
08-10-2020
English
15-08-1997
1 Scope
2 Normative references
3 Terminology
4 Test procedures
4.1 Test and measurement conditions
4.1.1 Measurement uncertainty
4.1.2 Alternative test methods
4.2 Visual inspection
4.2.1 Protective screen position
4.2.2 Quality of solder joints
4.3 Dimensioning and gauging procedure
4.4 Electrical test procedures
4.4.1 Winding resistance
4.4.2 Insulation tests
4.4.3 Losses
4.4.4 Inductance
4.4.5 Unbalance
4.4.6 Capacitance
4.4.7 Transformation ratios
4.4.8 Resonant frequency
4.4.9 Signal transfer characteristics
4.4.10 Frequency response
4.4.11 Pulse characteristics
4.4.12 Voltage-time product rating
4.4.13 Total harmonic distortion
4.4.14 Voltage regulation
4.4.15 Temperature rise
4.4.16 Surface temperature
4.4.17 Phase test (polarity)
4.4.18 Screens
4.4.19 Noise
4.4.20 Corona test
4.4.21 Magnetic fields
4.4.22 Inrush current
4.5 Environmental test procedures
4.5.1 General
4.5.2 Soldering
4.5.3 Robustness of terminations and integral
mounting devices
4.5.4 Shock
4.5.5 Bump
4.5.6 Vibration (sinusoidal)
4.5.7 Acceleration, steady state
4.5.8 Rapid change of temperature (thermal
shock in air)
4.5.9 Sealing
4.5.10 Climatic sequence
4.5.11 Damp heat, steady state
4.5.12 Dry heat
4.5.13 Mould grown
4.5.14 Salt mist, cyclic (sodium chloride
solution)
4.5.15 Sulphur dioxide test for contacts and
connections
4.5.16 Fire hazard
4.5.17 Immersion in cleaning solvents
4.6 Endurance test procedures
4.6.1 Short-term endurance (load run)
4.6.2 Long-term endurance (life test)
Annex
ZA Normative references to international publications
with their corresponding European publications
Covers measuring and test methods for inductors and transformers to be used in electronic and telecommunication equipment for specifications for those components, especially those making part of the IEC Quality Assessment system for Electronic Companies.
Committee |
EPL/51
|
DocumentType |
Standard
|
Pages |
66
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 61007 : 1998 | Identical |
SN EN 61007 : 1997 | Identical |
I.S. EN 61007:1998 | Identical |
IEC 61007:1994 | Identical |
EN 61007:1997 | Identical |
NBN EN 61007 : 1997 | Identical |
DIN EN 61007:1998-04 | Identical |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
HD 323.2.20 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST T - SOLDERING |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-58:2015+AMD1:2017 CSV | Environmental testing - Part 2-58: Tests - Test Td: Test methods for solderability, resistance to dissolution of metallization and to soldering heat of surface mounting devices (SMD) |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60367-1:1982 | Cores for inductors and transformers for telecommunications. Part 1: Measuring methods |
HD 323.2.13 : 200S1 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST M: LOW AIR PRESSURE |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
HD 323.2.17 : 200S4 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST Q: SEALING |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60695-2-4/1:1993/A1:1996 | FIRE HAZARD TESTING - TEST METHODS - KW NOMINAL PREMIXED TEST FLAME AND GUIDANCE |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
EN 60068-1:2014 | Environmental testing - Part 1: General and guidance |
ISO 3:1973 | Preferred numbers Series of preferred numbers |
HD 323.2.14 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST N: OF TEMPERATURE |
EN 60068-2-7:1993 | Environmental testing - Part 2: Tests - Test Ga: Acceleration, steady state |
IEC 60027-1:1992 | Letters symbols to be used in electrical technology - Part 1: General |
HD 323.2.30 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - PART 2: TESTS - TEST DB AND GUIDANCE: DAMP HEAT, CYCLIC (12 + 12-HOUR CYCLE) |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
HD 323.2.3 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
HD 323.2.6 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST FC AND GUIDANCE: VIBRATION (SINUSOIDAL) |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60068-2-10:2005 | Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth |
EN 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60551:1992/A1:1997 | DETERMINATION OF TRANSFORMER AND REACTOR SOUND LEVELS |
EN 60695-2-4-0 : 1993 | FIRE HAZARD TESTING - PART 2: TEST METHODS - SECTION 4/SHEET 0: DIFFUSION TYPE AND PREMIXED TYPE FLAME TEST METHODS |
HD 323.2.10 : 200S3 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST J AND GUIDANCE: MOULD GROWTH |
IEC 60068-2-42:2003 | Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
ISO 497:1973 | Guide to the choice of series of preferred numbers and of series containing more rounded values of preferred numbers |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60044-4:1980 | Instrument transformers - Part 4: Measurement of partial discharges |
EN 60651:1994/A2:2001 | SOUND LEVEL METERS (IEC 60651:1979/A2:2000) |
HD 245.1 : 200S3 | LETTER SYMBOLS TO BE USED IN ELECTRICAL TECHNOLOGY - GENERAL |
HD 323.2.58 : 200S1 | TEST TD: SOLDERABILITY, RESISTANCE TO DISSOLUTION OF METALIZATION AND TO SOLDERING HEAT OF SURFACE MOUNTING DEVICES (SMD) |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 60068-2-45:1992/A1:1993 | Environmental testing - Part 2: Tests - Test Xa and guidance: Immersion in cleaning solvents |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
EN 60695-2-2:1994/A1:1995 | FIRE HAZARD TESTING - TEST METHODS - NEEDLE-FLAME TEST |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
HD 323.2.52 : 200S1 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST KB: SALT MIST, CYCLIC (SODIUM CHLORIDE SOLUTION) |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.