BS EN 61779-1:2000
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Electrical apparatus for the detection and measurement of flammable gases General requirements and test methods
Hardcopy , PDF
01-11-2010
English
29-10-2004
1 General
1.1 Scope
1.2 Normative references
2 Definitions
2.1 Gas properties
2.2 Types of instruments
2.3 Sensors
2.4 Supply of gas to instrument
2.5 Signals and alarms
2.6 Times
2.7 Miscellaneous
3 General requirements
3.1 Introduction
3.2 Construction
4 Test methods
4.1 Introduction
4.2 General requirements for tests
4.3 Normal conditions for tests
4.4 Test methods
5 Field calibration kit
6 Information for use
Annex A (normative) Flammability limits (i.e. LFL and UFL)
of some flammable gases and vapours
Annex B (informative) Determination of time of response
Annex C (informative) Bibliography
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Gives general requirements for the construction and testing and describes the test methods applicable to portable, transportable and fixed apparatus for detecting and measuring flammable gas or vapour concentrations with air. The apparatus, or parts of apparatus are meant for use in potentially explosive atmospheres and in mines susceptible to firedamp. This standard is supplemented by the following standards: IEC 61779-2, IEC 61779-3, IEC 61779-4 and IEC 61779-5.
Committee |
EXL/31
|
DevelopmentNote |
Supersedes BS EN 50054. (08/2000) Supersedes 99/242136 DC. (11/2004)
|
DocumentType |
Standard
|
Pages |
60
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists. This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low-voltage power distribution system if this apparatus is intended to be used in the locations described below. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations which are included: - residential properties, for example houses, apartments; - retail outlets, for example shops, supermarkets; - business premises, for example offices, banks; - areas of public entertainment, for example cinemas, public bars, dance halls; - outdoor locations, for example petrol stations, car parks, amusement and sports centres; - light-industrial locations, for example workshops, laboratories, service centres. Locations which are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial. The immunity requirements have been selected to ensure an adequate level of immunity for apparatus at residential, commercial and light-industrial locations. The levels do not, however, cover extreme cases, which may occur at any location, but with an extremely low probability of occurrence. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These test requirements represent essential electromagnetic compatibility immunity requirements. Test requirements are specified for each port considered.
Standards | Relationship |
I.S. EN 61779-1:2003 | Identical |
SN EN 61779-1 : 2000 | Identical |
IEC 61779-1:1998 | Identical |
UNE-EN 61779-1:2002 | Identical |
NF EN 61779-1 : 2005 AMD 11 2005 | Identical |
DIN EN 61779-1 : 2001 AMD 11 2004 | Identical |
NBN EN 61779-1 : 2001 AMD 1 2005 | Identical |
EN 61779-1 : 2000 AMD 11 2004 | Identical |
BS 8008(1996) : 1996 | GUIDE TO SAFETY PRECAUTIONS AND PROCEDURES FOR THE CONSTRUCTION AND DESCENT OF MACHINE-BORED SHAFTS FOR PILING AND OTHER PURPOSES |
BS 8494:2007 | Electronic portable and transportable apparatus designed to detect and measure carbon dioxide in indoor ambient air. Requirements and test methods |
07/30154996 DC : 0 | BS 8494 - ELECTRONIC PORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE IN INDOOR AMBIENT AIR |
IEC 60050-351:2013 | International Electrotechnical Vocabulary (IEV) - Part 351: Control technology |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 50270:2015 | Electromagnetic compatibility - Electrical apparatus for the detection and measurement of combustible gases, toxic gases or oxygen |
IEC 60079-10:2002 | Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 60079-19:2010+AMD1:2015 CSV | Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
ISO 6147:1979 | Gas analysis Preparation of calibration gas mixtures Saturation method |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
ISO 6142:2001 | Gas analysis Preparation of calibration gas mixtures Gravimetric method |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
EN 50073:1999 | Guide for selection, installation, use and maintenance of apparatus for the detection and measurement of combustible gases or oxygen |
ISO 6145-4:2004 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4: Continuous syringe injection method |
ISO 6145-3:1986 | Gas analysis Preparation of calibration gas mixtures Dynamic volumetric methods Part 3: Periodic injections into a flowing gas stream |
ISO 6145-1:2003 | Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 1: Methods of calibration |
ISO 6145-6:2017 | Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 60079-13:2017 | Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" |