• Shopping Cart
    There are no items in your cart

CLC/TS 60034-31:2011

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by

Rotating electrical machines - Part 31: Selection of energy-efficient motors including variable speed applications - Application guide

Withdrawn date

11-09-2023

Superseded by

EN 60034-30-1:2014

Published date

25-02-2011

Sorry this product is not available in your region.

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 General
5 Efficiency
6 Environment
7 Applications
8 Economy
9 Maintenance
Annex A (informative) - Super-premium efficiency
        (IE4)
Bibliography
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications

IEC/TS 60034-31:2010 provides a guideline of technical aspects for the application of energy-efficient, three-phase, electric motors. It not only applies to motor manufacturers, original equipment manufacturers, end users, regulators and legislators but to all other interested parties. Is applicable to all electrical machines covered by IEC 60034-30.

Committee
CLC/TC 2
DocumentType
Technical Specification
PublisherName
European Committee for Standards - Electrical
Status
Withdrawn
SupersededBy

VDE 0160-109-2 : 2018-01 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 9-2: ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS AND THEIR DRIVEN APPLICATIONS - ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS (IEC 61800-9-2:2017)
DIN EN 61800-9-2 : 2018-01 ADJUSTABLE SPEED ELECTRICAL POWER DRIVE SYSTEMS - PART 9-2: ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS AND THEIR DRIVEN APPLICATIONS - ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS (IEC 61800-9-2:2017)
BS EN 50598-2 : 2014 ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS & THEIR DRIVEN APPLICATIONS - PART 2: ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS
UNE-EN 50598-2:2015 Ecodesign for power drive systems, motor starters, power electronics & their driven applications - Part 2: Energy efficiency indicators for power drive systems and motor starters
I.S. EN 50598-2:2014 ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS & THEIR DRIVEN APPLICATIONS - PART 2: ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS
EN 50598-2:2014/A1:2016 ECODESIGN FOR POWER DRIVE SYSTEMS, MOTOR STARTERS, POWER ELECTRONICS & THEIR DRIVEN APPLICATIONS - PART 2: ENERGY EFFICIENCY INDICATORS FOR POWER DRIVE SYSTEMS AND MOTOR STARTERS

IEC 61800-2:2015 Adjustable speed electrical power drive systems - Part 2: General requirements - Rating specifications for low voltage adjustable speed a.c. power drive systems
EN 60034-30:2009 Rotating electrical machines - Part 30: Efficiency classes of single-speed, three-phase, cage-induction motors (IE-code)
NEMA MG 1 : 2016 MOTORS AND GENERATORS
NEMA MG 11 : 1977(R2012) ENERGY MANAGEMENT GUIDE FOR SELECTION AND USE OF SINGLE-PHASE MOTORS
NEMA MG 10:2017 Energy Management Guide for Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors
EN 60034-1:2010/corrigendum Oct. 2010 ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE
IEC 60300-3-3:2017 Dependability management - Part 3-3: Application guide - Life cycle costing
NEMA ICS 7.1:2014 Safety Standards for Construction and Guide for Selection, Installation and Operation of Adjustable Speed Drive Systems
ISO 3:1973 Preferred numbers Series of preferred numbers
IEC 60072-1:1991 Dimensions and output series for rotating electrical machines - Part 1: Frame numbers 56 to 400 and flange numbers 55 to 1080
IEC TS 61800-8:2010 Adjustable speed electrical power drive systems - Part 8: Specification of voltage on the power interface
IEC 60034-2-1:2014 Rotating electrical machines - Part 2-1: Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles)
IEC TS 60034-25:2014 Rotating electrical machines - Part 25: AC electrical machines used in power drive systems - Application guide
IEC 61241-1:2004 Electrical apparatus for use in the presence of combustible dust - Part 1: Protection by enclosures "tD"
IEC TS 60034-17:2006 Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide
IEC 60034-26:2006 Rotating electrical machines - Part 26: Effects of unbalanced voltages on the performance of three-phase cage induction motors
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEC 60034-12:2016 Rotating electrical machines - Part 12: Starting performance of single-speed three-phase cage induction motors
IEEE 112-2004 IEEE Standard Test Procedure for Polyphase Induction Motors and Generators
IEC 60034-30:2008 Rotating electrical machines - Part 30: Efficiency classes of single-speed, three-phase, cage-induction motors (IE-code)
EN 50347:2001 General purpose three-phase induction motors having standard dimensions and outputs - Frame numbers 56 to 315 and flange numbers 65 to 740