DIN EN 13830:2015-07
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
CURTAIN WALLING - PRODUCT STANDARD
Hardcopy , PDF
01-01-2015
30-11-2020
National foreword
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
4 Product characteristics
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of
performance (AVCP)
7 Marking, labelling
Annex A (informative) - Maintenance
Annex B (informative) - Equipotential bonding
conditions
Annex C (informative) - Resistance to actions:
guidance on the use of Eurocodes
Annex D (normative) - Seismic resistance
Annex E (normative) - Selection, preparation,
mounting and fixing of test specimen for
reaction to fire tests of curtain walling and
field of direct application
Annex F (normative) - Characteristics and range
of direct application
Annex G (informative) - Characteristics and
performances of curtain walling kit
Annex H (informative) - Interchangeability between
characteristics and components
Annex I (informative) - Basic approach to durability
Annex ZA (informative) - Clauses of this standard
addressing the provisions of the EU
Construction Product Regulation
Bibliography
Defines requirements of curtain walling kit intended to be used as a building envelope to provide weather resistance, safety in use and energy economy and heat retention and provides test/assessments/calculation methods and compliance criteria of the related performances.
| DocumentType |
Standard
|
| Pages |
91
|
| PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| I.S. EN 13830:2015 | Equivalent |
| EN 13830:2015 | Equivalent |
| EN 13051:2001 | Curtain Walling - Watertightness - Site test |
| EN 13022-1:2014 | Glass in building - Structural sealant glazing - Part 1: Glass products for structural sealant glazing systems for supported and unsupported monolithic and multiple glazing |
| EN 13168:2012+A1:2015 | Thermal insulation products for buildings - Factory made wood wool (WW) products - Specification |
| EN 12153:2000 | Curtain walling - Air permeability - Test method |
| EN 13116:2001 | Curtain walling - Resistance to wind load - Performance requirements |
| ISO 9047:2001 | Building construction — Jointing products — Determination of adhesion/cohesion properties of sealants at variable temperatures |
| EN 13050:2011 | Curtain Walling - Watertightness - Laboratory test under dynamic condition of air pressure and water spray |
| ISO 10848-2:2017 | Acoustics — Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms — Part 2: Application to Type B elements when the junction has a small influence |
| ISO 10848-1:2017 | Acoustics — Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms — Part 1: Frame document |
| EN 1364-3:2014 | Fire resistance tests for non-loadbearing elements - Part 3: Curtain walling - Full configuration (complete assembly) |
| ISO 12631:2017 | Thermal performance of curtain walling — Calculation of thermal transmittance |
| EN 1096-4:2004 | Glass in building - Coated glass - Part 4: Evaluation of conformity/Product standard |
| EN ISO 9046:2004 | Building construction - Jointing products - Determination of adhesion/cohesion properties of sealants at constant temperature (ISO 9046:2002) |
| ISO 10140-2:2010 | Acoustics — Laboratory measurement of sound insulation of building elements — Part 2: Measurement of airborne sound insulation |
| EN 12758:2011 | Glass in building - Glazing and airborne sound insulation - Product descriptions and determination of properties |
| EN 410:2011 | Glass in building - Determination of luminous and solar characteristics of glazing |
| ISO 1716:2010 | Reaction to fire tests for products — Determination of the gross heat of combustion (calorific value) |
| EN 13164:2012+A1:2015 | Thermal insulation products for buildings - Factory made extruded polystyrene foam (XPS) products - Specification |
| EN 15434:2006+A1:2010 | Glass in building - Product standard for structural and/or ultra-violet resistant sealant (for use with structural sealant glazing and/or insulating glass units with exposed seals) |
| EN ISO 10140-4:2010 | Acoustics - Laboratory measurement of sound insulation of building elements - Part 4: Measurement procedures and requirements (ISO 10140-4:2010) |
| ISO 10140-1:2016 | Acoustics — Laboratory measurement of sound insulation of building elements — Part 1: Application rules for specific products |
| ISO 11925-2:2010 | Reaction to fire tests — Ignitability of products subjected to direct impingement of flame — Part 2: Single-flame source test |
| EN ISO 1182:2010 | Reaction to fire tests for products - Non-combustibility test (ISO 1182:2010) |
| EN 15651-2:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 2: Sealants for glazing |
| ISO 10590:2005 | Building construction — Sealants —- Determination of tensile properties of sealants at maintained extension after immersion in water |
| EN ISO 12631:2017 | Thermal performance of curtain walling - Calculation of thermal transmittance (ISO 12631:2017) |
| EN ISO 10140-1:2016 | Acoustics - Laboratory measurement of sound insulation of building elements - Part 1: Application rules for specific products (ISO 10140-1:2016) |
| EN 13166:2012+A2:2016 | Thermal insulation products for buildings - Factory made phenolic foam (PF) products - Specification |
| EN 13501-2:2016 | Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services |
| ISO 11600:2002 | Building construction — Jointing products — Classification and requirements for sealants |
| EN 13238:2010 | Reaction to fire tests for building products - Conditioning procedures and general rules for selection of substrates |
| ISO 10140-4:2010 | Acoustics — Laboratory measurement of sound insulation of building elements — Part 4: Measurement procedures and requirements |
| EN 14019:2016 | Curtain Walling - Impact resistance - Performance requirements |
| ISO 1182:2010 | Reaction to fire tests for products — Non-combustibility test |
| EN 12365-1:2003 | Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 1: Performance requirements and classification |
| EN ISO 10591:2005 | Building construction - Sealants - Determination of adhesion/cohesion properties of sealants after immersion in water (ISO 10591:2005) |
| EN 13823:2010+A1:2014 | Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item |
| EN 15651-1:2017 | Sealants for non-structural use in joints in buildings and pedestrian walkways - Part 1: Sealants for facade elements |
| EN 1279-3:2002 | Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances |
| EN 12354-1:2000 | Building Acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 1: Airborne sound insulation between rooms |
| EN 13162:2012+A1:2015 | Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification |
| ISO 12567-1:2010 | Thermal performance of windows and doors — Determination of thermal transmittance by the hot-box method — Part 1: Complete windows and doors |
| EN 13170:2012+A1:2015 | Thermal insulation products for buildings - Factory made products of expanded cork (ICB) - Specification |
| EN 1279-4:2002 | Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals |
| EN ISO 10848-1:2017 | Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 1: Frame document (ISO 10848-1:2017) |
| EN ISO 10590:2005 | Building construction - Sealants - Determination of tensile properties of sealants at maintained extension after immersion in water (ISO 10590:2005) |
| EN 12412-2:2003 | Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames |
| EN 12365-4:2003 | Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 4: Recovery after accelerated ageing test method |
| EN 13165:2012+A2:2016 | Thermal insulation products for buildings - Factory made rigid polyurethane foam (PU) products - Specification |
| EN 1279-5:2005+A2:2010 | Glass in building - Insulating glass units - Part 5: Evaluation of conformity |
| EN 1364-4:2014 | Fire resistance tests for non-loadbearing elements - Part 4: Curtain walling - Part configuration |
| EN 12155:2000 | Curtain walling - Watertightness - Laboratory test under static pressure |
| EN 13171:2012+A1:2015 | Thermal insulation products for buildings - Factory made wood fibre (WF) products - Specification |
| EN ISO 10140-2:2010 | Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation (ISO 10140-2:2010) |
| EN 12179:2000 | Curtain walling - Resistance to wind load - Test method |
| EN 13167:2012+A1:2015 | Thermal insulation products for buildings - Factory made cellular glass (CG) products - Specification |
| EN 1279-2:2002 | Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration |
| ISO 10591:2005 | Building construction — Sealants — Determination of adhesion/cohesion properties of sealants after immersion in water |
| EN 13119:2016 | Curtain walling - Terminology |
| ISO 8340:2005 | Building construction — Sealants — Determination of tensile properties at maintained extension |
| ISO 717-1:2013 | Acoustics — Rating of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation |
| EN 13163:2012+A2:2016 | Thermal insulation products for buildings - Factory made expanded polystyrene (EPS) products - Specification |
| ISO 9046:2002 | Building construction — Jointing products — Determination of adhesion/cohesion properties of sealants at constant temperature |
| EN ISO 13788:2012 | Hygrothermal performance of building components and building elements - Internal surface temperature to avoid critical surface humidity and interstitial condensation - Calculation methods (ISO 13788:2012, Corrected version 2020-05) |
| ISO 10140-3:2010 | Acoustics — Laboratory measurement of sound insulation of building elements — Part 3: Measurement of impact sound insulation |
| ISO 10140-5:2010 | Acoustics — Laboratory measurement of sound insulation of building elements — Part 5: Requirements for test facilities and equipment |
| EN ISO 8339:2005 | Building construction - Sealants - Determination of tensile properties (Extension to break) (ISO 8339:2005) |
| EN 1096-3:2012 | Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings |
| ISO 8339:2005 | Building construction — Sealants — Determination of tensile properties (Extension to break) |
| EN ISO 1716:2010 | Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2010) |
| EN ISO 8340:2005 | Building construction - Sealants - Determination of tensile properties at maintained extension (ISO 8340:2005) |
| EN 13169:2012+A1:2015 | Thermal insulation products for buildings - Factory made expanded perlite board (EPB) products - Specification |
| EN 13022-2:2014 | Glass in building - Structural sealant glazing - Part 2: Assembly rules |
| EN 12152:2002 | Curtain walling - Air permeability - Performance requirements and classification |
| EN 12154:1999 | Curtain walling - Watertightness - Performance requirements and classification |
| EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
| EN 1096-2:2012 | Glass in building - Coated glass - Part 2: Requirements and test methods for class A, B and S coatings |
| EN ISO 10848-2:2017 | Acoustics - Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms - Part 2: Application to Type B elements when the junction has a small influence (ISO 10848-2:2017) |