DIN EN ISO 80079-36:2016-12
Current
Current
The latest, up-to-date edition.
Explosive atmospheres - Part 36: Non-electrical equipment for explosive atmospheres - Basic method and requirements (ISO 80079-36:2016); German version EN ISO 80079-36:2016
Amended by
Available format(s)
Hardcopy , PDF
Language(s)
English, German
Published date
01-12-2016
DevelopmentNote |
Supersedes DIN EN 13463-1. (12/2016) DIN EN 13463-1 issue 07-2009 remains valid alongside this standard until 31-10-2019. (04/2017)
|
DocumentType |
Standard
|
Pages |
95
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Current
|
Supersedes |
Standards | Relationship |
EN ISO 80079-36:2016 | Identical |
ISO 80079-36:2016 | Identical |
DIN EN ISO/IEC 80079-38:2012-08 (Draft) | EXPLOSIVE ATMOSPHERES - PART 38: EQUIPMENT AND COMPONENTS IN EXPLOSIVE ATMOSPHERES IN UNDERGROUND MINES (ISO/IEC 80079-38:2016) |
VDI 2263 Blatt 6:2017-08 | Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in dust extracting installations |
DIN EN ISO 80079-37:2016-12 | Explosive atmospheres - Part 37: Non-electrical equipment for explosive atmospheres - Non-electrical type of protection constructional safety "c", control of ignition sources "b", liquid immersion "k" (ISO 80079-37:2016) |
IEC 61025:2006 | Fault tree analysis (FTA) |
ISO 6507-1:2005 | Metallic materials Vickers hardness test Part 1: Test method |
EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
ISO 6507-4:2005 | Metallic materials Vickers hardness test Part 4: Tables of hardness values |
IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
DIN EN ISO/IEC 80079-38:2012-08 (Draft) | EXPLOSIVE ATMOSPHERES - PART 38: EQUIPMENT AND COMPONENTS IN EXPLOSIVE ATMOSPHERES IN UNDERGROUND MINES (ISO/IEC 80079-38:2016) |
DIN EN 60079-1 : 2015-04 | EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES 'D' (IEC 60079-1:2014) |
DIN EN 60079-28 : 2016 | EXPLOSIVE ATMOSPHERES - PART 28: PROTECTION OF EQUIPMENT AND TRANSMISSION SYSTEMS USING OPTICAL RADIATION (IEC 60079-28:2015) |
IEC 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
EN 13237:2012 | Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
DIN EN 60079-0 : 2014 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED + COR.:2012 + COR.:2013) |
IEC 60079-20-1:2010 | Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
DIN EN 60079-2 : 2015 COR 1 2016 | EXPLOSIVE ATMOSPHERES - PART 2: EQUIPMENT PROTECTION BY PRESSURIZED ENCLOSURE 'P' (IEC 60079-2:2014) |
ISO 12100:2010 | Safety of machinery — General principles for design — Risk assessment and risk reduction |
ISO 281:2007 | Rolling bearings Dynamic load ratings and rating life |
ISO/IEC 80079-38:2016 | Explosive atmospheres Part 38: Equipment and components in explosive atmospheres in underground mines |
DIN EN 60079-31 : 2014 | EXPLOSIVE ATMOSPHERES - PART 31: EQUIPMENT DUST IGNITION PROTECTION BY ENCLOSURE 'T' (IEC 60079-31:2013) |
EN 1755:2015 | Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres |
EN 15198:2007 | Methodology for the risk assessment of non-electrical equipment and components for intended use in potentially explosive atmospheres |
ISO 80079-37:2016 | Explosive atmospheres Part 37: Non-electrical equipment for explosive atmospheres Non-electrical type of protection constructional safety 'c', control of ignition sources 'b', liquid immersion 'k' |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
ISO 16852:2016 | Flame arresters — Performance requirements, test methods and limits for use |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
DIN EN ISO 80079-37:2016-12 | Explosive atmospheres - Part 37: Non-electrical equipment for explosive atmospheres - Non-electrical type of protection constructional safety "c", control of ignition sources "b", liquid immersion "k" (ISO 80079-37:2016) |
IEC 60079-31:2013 | Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
IEC 60079-26:2014 RLV | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
CLC/TR 50404:2003 | Electrostatics - Code of practice for the avoidance of hazards due to static electricity |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.