EN 15456:2008
Current
The latest, up-to-date edition.
Heating boilers - Electrical power consumption for heat generators - System boundaries - Measurements
02-04-2008
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 System boundaries for measurements
4.1 General
4.2 System with circulator (pump) for heat generation
4.3 System with a single circulator (pump) for heat
generation and heat distribution
4.4 System without any circulator (pump)
4.5 Burner
5 Measurement
5.1 Heating boiler
5.1.1 Setting of the heating boiler
5.1.2 Determination of the water side resistance
5.1.3 Measurement modes
5.2 Forced-draught burners
5.3 Pellet burner
5.4 Oil stoves
5.5 Determination of the water side resistance
5.6 Test report and documentation
Annex A (normative) - Test report
A.1 Summary
A.2 Testing the electrical power consumption P[aux]
Annex B (informative) - Determination of the water side
resistance
B.1 Operating conditions
B.1.1 General
B.1.2 Boilers without integrated pump
B.1.3 Boilers with integrated pump
B.1.4 Determination of operating conditions of
boilers with integrated pump
Bibliography
This European Standard applies to heating boilers (e.g. with forced-draught burners (unit)) and burners equipped with a fan including all components specified by the manufacturer to be required for the designed boiler operation.This European Standard also applies to heating boilers sold without burners.This European Standard covers the required definitions, the system boundaries, the measurements for the determination of the electrical power consumption and, where applicable, the water side resistance in order to establish the electric auxiliary energy for:Oil-fired forced-draught burners in accordance with EN 267;Automatic forced-draught burners for gaseous fuels in accordance with EN 676;Flued oil stoves with vaporizing burners in accordance with EN 1;Heating boilers sold without burners for:Oil-fired forced-draught burners in accordance with EN 303-1 [6], EN 303-2 [7] and EN 304; Condensing boilers for liquid fuels in accordance with EN 15034;Room sealed boilers for fuel oil in accordance with EN 15035;Heating boilers - Heating boilers with forced-draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C in accordance with EN 14394;Pellet burners for small heating boilers in accordance with EN 15270.NOTEAll measurements for boilers are carried out in the heating mode only. For hot water production this mode is also relevant.
Committee |
CEN/TC 57
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNE-EN 15456:2009 | Identical |
UNI EN 15456 : 2008 | Identical |
NEN EN 15456 : 2008 | Identical |
BS EN 15456:2008 | Identical |
NF EN 15456 : 2008 | Identical |
NS EN 15456 : 1ED 2008 | Identical |
SN EN 15456 : 2008 | Identical |
DIN EN 15456:2008-06 | Identical |
NBN EN 15456 : 2008 | Identical |
I.S. EN 15456:2008 | Identical |
PN EN 15456 : 2008 | Identical |
BS EN 15502-1 : 2012 | GAS-FIRED HEATING BOILERS - PART 1: GENERAL REQUIREMENTS AND TESTS |
16/30338096 DC : 0 | BS EN 303-1 - HEATING BOILERS - PART 1: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - TERMINOLOGY, GENERAL REQUIREMENTS, TESTING AND MARKING |
PREN 15316-4-1 : DRAFT 2014 | HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS) |
ISO 13675:2013 | Heating systems in buildings — Method and design for calculation of the system energy performance — Combustion systems (boilers) |
PREN 303-1 : DRAFT 2016 | HEATING BOILERS - PART 1: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - TERMINOLOGY, GENERAL REQUIREMENTS, TESTING AND MARKING |
I.S. EN 15502-1:2012 | GAS-FIRED HEATING BOILERS - PART 1: GENERAL REQUIREMENTS AND TESTS |
BS EN 304:2017 | Heating boilers. Test code for heating boilers for atomizing oil burners |
EN 15316-4-1:2017 | Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-1: Space heating and DHW generation systems, combustion systems (boilers, biomass), Module M3-8-1, M8-8-1 |
BS EN 303-5:2012 | Heating boilers Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW. Terminology, requirements, testing and marking |
BS EN 303-2:2017 | Heating boilers Heating boilers with forced draught burners. Special requirements for boilers with atomizing oil burners |
I.S. EN 303-2:2017 | HEATING BOILERS - PART 2: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - SPECIAL REQUIREMENTS FOR BOILERS WITH ATOMIZING OIL BURNERS |
DIN EN 303-1:2016-07 (Draft) | HEATING BOILERS - PART 1: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - TERMINOLOGY, GENERAL REQUIREMENTS, TESTING AND MARKING |
16/30338099 DC : 0 | BS EN 304 - HEATING BOILERS - TEST CODE FOR HEATING BOILERS FOR ATOMIZING OIL BURNERS |
14/30311499 DC : 0 | BS EN 15316-4-1 - HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS) |
I.S. EN 304:2017 | HEATING BOILERS - TEST CODE FOR HEATING BOILERS FOR ATOMIZING OIL BURNERS |
UNE-EN 15316-4-1:2010 | Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-1: Space heating generation systems, combustion systems (boilers) |
PREN 303-2 : DRAFT 2016 | HEATING BOILERS - PART 2: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - SPECIAL REQUIREMENTS FOR BOILERS WITH ATOMIZING OIL BURNERS |
EN 304:2017 | Heating boilers - Test code for heating boilers for atomizing oil burners |
DIN EN 303-2:2016-07 (Draft) | HEATING BOILERS - PART 2: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - SPECIAL REQUIREMENTS FOR BOILERS WITH ATOMIZING OIL BURNERS |
DIN EN 303-5:2012-10 | Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking |
I.S. EN 303-1:2017 | HEATING BOILERS - PART 1: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - TERMINOLOGY, GENERAL REQUIREMENTS, TESTING AND MARKING |
I.S. EN 303-5:2012 | HEATING BOILERS - PART 5: HEATING BOILERS FOR SOLID FUELS, MANUALLY AND AUTOMATICALLY STOKED, NOMINAL HEAT OUTPUT OF UP TO 500 KW - TERMINOLOGY, REQUIREMENTS, TESTING AND MARKING |
EN 303-5:2012 | Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking |
10/30218092 DC : 0 | BS EN 15502-1 - GAS-FIRED HEATING BOILERS - PART 1: GENERAL REQUIREMENTS AND TESTS |
UNI EN 303-5 : 2012 | HEATING BOILERS - PART 5: HEATING BOILERS FOR SOLID FUELS, MANUALLY AND AUTOMATICALLY STOKED, NOMINAL HEAT OUTPUT OF UP TO 500 KW - TERMINOLOGY, REQUIREMENTS, TESTING AND MARKING |
PREN 304 : DRAFT 2016 | HEATING BOILERS - TEST CODE FOR HEATING BOILERS FOR ATOMIZING OIL BURNERS |
PD CEN/TR 15316-6-4:2017 | Energy performance of buildings. Method for calculation of system energy requirements and system efficiencies Explanation and justification of EN 15316-4-1, Module M3-8-1, M8-8-1 |
DIN EN 15502-1:2015-10 | Gas-fired heating boilers - Part 1: General requirements and tests (includes Amendment A1:2015) |
CEN/TR 15316-6-4:2017 | Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 6-4: Explanation and justification of EN 15316-4-1, Module M3-8-1, M8-8-1 |
EN 303-2:2017 | Heating boilers - Part 2: Heating boilers with forced draught burners - Special requirements for boilers with atomizing oil burners |
EN 303-1:2017 | Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking |
DIN EN 15316-4-1:2008-09 | ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS), MODULE M3-8-1, M8-8-1 |
S.R. CEN/TR 15316-6-4:2017 | ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 6-4: EXPLANATION AND JUSTIFICATION OF EN 15316-4-1, MODULE M3-8-1, M8-8-1 |
16/30338102 DC : 0 | BS EN 303-2 - HEATING BOILERS - PART 2: HEATING BOILERS WITH FORCED DRAUGHT BURNERS - SPECIAL REQUIREMENTS FOR BOILERS WITH ATOMIZING OIL BURNERS |
12/30239784 DC : 0 | BS ISO 13675 - HEATING AND COOLING SYSTEMS IN BUILDINGS - METHOD AND DESIGN FOR CALCULATION OF THE SYSTEM ENERGY PERFORMANCE - COMBUSTION SYSTEMS (BOILERS) |
BS ISO 13675:2013 | Heating systems in buildings. Method and design for calculation of the system energy performance. Combustion systems (boilers) |
PREN 15502-1 : DRAFT 2010 | GAS-FIRED HEATING BOILERS - PART 1: GENERAL REQUIREMENTS AND TESTS |
I.S. EN 15316-4-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS), MODULE M3-8-1, M8-8-1 |
UNE-EN 303-5:2013 | Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking |
BS EN 303-1:2017 | Heating boilers Heating boilers with forced draught burners. Terminology, general requirements, testing and marking |
EN 15502-1:2012+A1:2015 | Gas-fired heating boilers - Part 1: General requirements and tests |
UNE-EN 15502-1:2013 | Gas-fired heating boilers - Part 1: General requirements and tests |
EN 15270:2007 | Pellet burners for small heating boilers - Definitions, requirements, testing, marking |
EN 14394:2005+A1:2008 | Heating boilers - Heating boilers with forced draught burners - Nominal heat output not exceeding 10 MW and maximum operating temperature of 110 °C |
PREN 15316-4-1 : DRAFT 2014 | HEATING SYSTEMS AND WATER BASED COOLING SYSTEMS IN BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-1: SPACE HEATING AND DHW GENERATION SYSTEMS, COMBUSTION SYSTEMS (BOILERS, BIOMASS) |
EN 304:2017 | Heating boilers - Test code for heating boilers for atomizing oil burners |
PREN 15502-1 : DRAFT 2010 | GAS-FIRED HEATING BOILERS - PART 1: GENERAL REQUIREMENTS AND TESTS |
EN 303-1:2017 | Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking |
EN 267:2009+A1:2011 | Automatic forced draught burners for liquid fuels |
EN 303-2:2017 | Heating boilers - Part 2: Heating boilers with forced draught burners - Special requirements for boilers with atomizing oil burners |
EN 437:2003+A1:2009 | Test gases - Test pressures - Appliance categories |
92/42/EEC : 1992 AMD 5 2013 | COUNCIL DIRECTIVE 92/42/EEC OF 21 MAY 1992 ON EFFICIENCY REQUIREMENTS FOR NEW HOT-WATER BOILERS FIRED WITH LIQUID OR GASEOUS FUELS |
EN 15035:2006 | Heating boilers - Special requirements for oil fired room sealed units up to 70 kW |