EN 50121-5:2017
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Railway applications - Electromagnetic compatibility - Part 5: Emission and immunity of fixed power supply installations and apparatus
06-02-2020
10-03-2017
European foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Performance criteria
5 Emission tests and limits
6 Immunity requirements
7 Fixed power supplies on railway property
which are not used for railway traction Purposes
Annex A (informative) - Emission within the
boundary of the substation for normal
operation and during the operation of switches
Annex ZZ (informative) - Relationship between this
European Standard and the essential requirements
of Directive 2014/30/EU [2014 OJ L96] aimed to
be covered
Bibliography
This European Standard applies to emission and immunity aspects of EMC for electrical and electronic apparatus and systems intended for use in railway fixed installations for power supply. This includes the power feed to the apparatus, the apparatus itself with its protective control circuits, trackside items such as switching stations, power autotransformers, booster transformers, substation power switchgear and power switchgear to other longitudinal and local supplies.Filters operating at railway system voltage (for example, for harmonic suppression or power factor correction) are not included in this standard since each site has special requirements. Filters would normally have separate enclosures with separate rules for access. If electromagnetic limits are required, these will appear in the specification for the equipment.If a port is intended to transmit or receive for the purpose of radio communication (intentional radiators, e.g. transponder systems), then the radiated emission requirement in this standard are not intended to be applicable to the intentional transmission from a radio-transmitter as defined by the ITU.The frequency range considered is from DC to 400 GHz. No measurements need to be performed at frequencies where no requirement is specified.Emission and immunity limits are given for items of apparatus which are situated:a)within the boundary of a substation which delivers electric power to a railway;b)beside the track for the purpose of controlling or regulating the railway power supply, including power factor correction;c)along the track for the purpose of supplying electrical power to the railway other than by means of the conductors used for contact current collection, and associated return conductors. Included are high voltage feeder systems within the boundary of the railway which supply substations at which the voltage is reduced to the railway system voltage;d) beside the track for controlling or regulating electric power supplies to ancillary railway uses. This category includes power supplies to marshalling yards, maintenance depots and stations;e) various other non-traction power supplies from railway sources which are shared with railway traction.The immunity levels given in this standard apply for:-vital equipment such as protection devices;-equipment having connections to the traction power conductors;-apparatus inside the 3 m zone;-ports of apparatus inside the 10 m zone with connection inside the 3 m zone;-ports of apparatus inside the 10 m zone with cable length > 30 m.Apparatus and systems which are in an environment which can be described as residential, commercial or light industry, even when placed within the physical boundary of the railway substation, shall comply with EN 61000 6 1:2007 for immunity and EN 61000 6 3:2007 for emission requirements.Excluded from the immunity requirements of this standard is power supply apparatus which is intrinsically immune to the tests defined in Tables 1 to 6.NOTEAn example is an 18 MVA 230 kV to 25 kV power supply transformer.These specific provisions are to be used in conjunction with the general provisions in EN 50121 1.This part of the standard covers requirements for both apparatus and fixed installations. The sections for fixed installations are not relevant for CE marking.
Committee |
CLC/TC 9X
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
I.S. EN 50121-5:2017/A1:2019 | Identical |
DS EN 50121-5 : 2017 | Identical |
NEN EN 50121-5 : 2017 | Identical |
DIN EN 50121-5 : 2017 | Identical |
CEI EN 50121-5 : 2016 | Identical |
NF EN 50121-5 : 2017 | Identical |
NBN EN 50121-5 : 2015 | Identical |
I.S. EN 50121-5:2017 | Identical |
UNE-EN 50121-5:2015 | Identical |
BS EN 50121-5:2017 | Identical |
PN EN 50121-5 : 2017 | Identical |
UNE-EN 50121-5:2018 | Identical |
SN EN 50121-5 : 2016 | Identical |
VDE 0115-121-5 : 2017 | Identical |
ONORM OVE EN 50121-5 : 2017 | Identical |
17/30341004 DC : 0 | BS EN 50238-1 - RAILWAY APPLICATIONS - COMPATIBILITY BETWEEN ROLLING STOCK AND TRAIN DETECTION SYSTEMS - PART 1: GENERAL |
PREN 50152-3-1 : DRAFT 2015 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-1: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - DEVICES |
BS EN 50329 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
15/30314789 DC : 0 | BS EN 50152-3-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-1: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - DEVICES |
11/30235280 DC : 0 | BS EN 50152-1 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
PREN 15654-1 : DRAFT 2015 | RAILWAY APPLICATIONS - MEASUREMENT OF VERTICAL FORCES ON WHEELS AND WHEELSETS - PART 1: INTEROPERABLE ON-TRACK MEASUREMENT SITES FOR VEHICLES IN SERVICE |
PD CLC/TR 50646:2015 | Railway Application. Fixed Installations. Specification for reversible d.c. substations |
PREN 50152-3-2 : DRAFT 2015 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS |
CEI EN 50125-2 : 2003 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
EN 50152-3-1:2017 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-1: Measurement, control and protection devices for specific use in a.c. traction systems - Devices |
EN 50152-3-2:2016 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers |
BS EN 50152-1 : 2012 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
12/30241400 DC : 0 | BS EN 15654-1 - RAILWAY APPLICATIONS - MEASUREMENT OF WHEEL AND AXLE LOADS - PART 1: INTEROPERABLE 'IN-SERVICE' RAIL VEHICLES |
UNE-EN 50152-2:2013 | Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 2: Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
15/30326124 DC : 0 | BS EN 15654-1 - RAILWAY APPLICATIONS - MEASUREMENT OF VERTICAL FORCES ON WHEELS AND WHEELSETS - PART 1: INTEROPERABLE ON-TRACK MEASUREMENT SITES FOR VEHICLES IN SERVICE |
DIN EN 50123-7-2 : 2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 7-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN D.C. TRACTION SYSTEMS - ISOLATING CURRENT TRANSDUCERS AND OTHER CURRENT MEASURING DEVICES |
13/30252768 DC : 0 | BS EN 50121-2 - RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD |
15/30314795 DC : 0 | BS EN 50152-3-3 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS |
PREN 50152-3-3 : DRAFT 2015 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-3: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE INDUCTIVE VOLTAGE TRANSFORMERS |
15/30314792 DC : 0 | BS EN 50152-3-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS |
BS EN 50327:2003 | Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups |
UNE-EN 50121-2:2017 | Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world |
PD CLC/TR 50451:2007 | Railway applications. Systematic allocation of safety integrity requirements |
AS/RISSB 7505 : 2014 | Railway Rolling Stock – Signal Detection Interface Signalling Detection Interface |
AS/RISSB 7722 : 2016 | EMC Management |
PREN 50152-1 : DRAFT 2011 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
I.S. EN 50152-3-2:2016 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - SINGLE-PHASE CURRENT TRANSFORMERS |
BS EN 50121-2:2017 | Railway applications. Electromagnetic compatibility Emission of the whole railway system to the outside world |
I.S. EN 15654-1:2018 | RAILWAY APPLICATIONS - MEASUREMENT OF VERTICAL FORCES ON WHEELS AND WHEELSETS - PART 1: ON-TRACK MEASUREMENT SITES FOR VEHICLES IN SERVICE |
CEI CLC/TR 50451 : 2008 | RAILWAY APPLICATIONS - SYSTEMATIC ALLOCATION OF SAFETY INTEGRITY REQUIREMENTS |
UNE-EN 50152-3-2:2016 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-2: Measurement, control and protection devices for specific use in a.c. traction systems - Current transformers |
UNE-EN 50152-3-1:2017 | Railway applications - Fixed installations - Particular requirements for a.c. switchgear - Part 3-1: Measurement, control and protection devices for specific use in a.c. traction systems - Devices |
07/30137492 DC : 0 | EN 15654-1 - RAILWAY APPLICATIONS - MEASUREMENT OF WHEEL AND AXLE LOADS - PART 1: INTEROPERABLE 'IN-SERVICE' RAIL VEHICLES |
CEI EN 50152-3-2 : 2001 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-2: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - CURRENT TRANSFORMERS |
I.S. EN 50152-3-1:2017 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR A.C. SWITCHGEAR - PART 3-1: MEASUREMENT, CONTROL AND PROTECTION DEVICES FOR SPECIFIC USE IN A.C. TRACTION SYSTEMS - DEVICES |
11/30235283 DC : 0 | BS EN 50152-2 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
UNE-EN 50152-1:2013 | Railway applications - Fixed installations - Particular requirements for alternating current switchgear - Part 1: Circuit-breakers with nominal voltage above 1 kV |
PREN 50238-1 : DRAFT 2017 | RAILWAY APPLICATIONS - COMPATIBILITY BETWEEN ROLLING STOCK AND TRAIN DETECTION SYSTEMS - PART 1: GENERAL |
BS EN 50152-2:2012 | Railway applications. Fixed installations. Particular requirements for alternating current switchgear Disconnectors, earthing switches and switches with nominal voltage above 1 kV |
16/30208484 DC : 0 | BS EN 15654-2 - RAILWAY APPLICATIONS - MEASUREMENT OF VERTICAL FORCES ON WHEELS AND WHEELSETS - PART 2: TEST IN WORKSHOP FOR NEW, MODIFIED AND MAINTAINED VEHICLES |
S.R. CLC/TR 50451:2007 | RAILWAY APPLICATIONS - SYSTEMATIC ALLOCATION OF SAFETY INTEGRITY REQUIREMENTS |
I.S. EN 50152-1:2012 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
I.S. EN 50125-2:2003 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
CLC/TR 50451:2007 | Railway applications - Systematic allocation of safety integrity requirements |
PREN 50152-2 : DRAFT 2011 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
I.S. EN 50152-2:2012 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
CEI EN 50152-2 : 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
EN 50125-2:2002/corrigendum:2010 | RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS |
I.S. EN 50327:2003 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
16/30340728 DC : 0 | BS EN 50121-2 - RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD |
BS EN 50125-2:2002 | Railway applications. Environmental conditions for equipment Fixed electrical installations |
S.R. CLC/TR 50646:2015 | RAILWAY APPLICATION - FIXED INSTALLATIONS - SPECIFICATION FORREVERSIBLE D.C. SUBSTATIONS |
04/30116625 DC : DRAFT JUL 2004 | EN 50121-2 - RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD |
I.S. EN 50121-2:2017 | RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD |
EN 50121-2:2017 | Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world |
I.S. EN 50329:2007 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
BS EN 50152-3-1:2017 | Railway applications. Fixed installations. Particular requirements for a.c. switchgear Measurement, control and protection devices for specific use in a.c. traction systems. Devices |
PREN 50121-2 : DRAFT 2016 | RAILWAY APPLICATIONS - ELECTROMAGNETIC COMPATIBILITY - PART 2: EMISSION OF THE WHOLE RAILWAY SYSTEM TO THE OUTSIDE WORLD |
EN 15654-1:2018 | Railway applications - Measurement of vertical forces on wheels and wheelsets - Part 1: On-track measurement sites for vehicles in service |
EN 50327 : 2003 AMD 1 2005 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
EN 50329:2003/A1:2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
EN 50152-2:2012 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 2: DISCONNECTORS, EARTHING SWITCHES AND SWITCHES WITH NOMINAL VOLTAGE ABOVE 1 KV |
EN 50152-1 : 2012 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - PARTICULAR REQUIREMENTS FOR ALTERNATING CURRENT SWITCHGEAR - PART 1: CIRCUIT-BREAKERS WITH NOMINAL VOLTAGE ABOVE 1 KV |
CLC/TR 50646:2015 | Railway Application - Fixed Installations - Specification for reversible d.c. substations |
IEC 61000-6-2:2016 | Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments |
EN 61000-3-11:2000 | Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
EN 50121-1:2017 | Railway applications - Electromagnetic compatibility - Part 1: General |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-3-12:2011 | Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
EN 61000-6-2:2005/corrigendum:2005 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS (IEC 61000-6-2:2005) |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
EN 61000-6-4:2007/A1:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-4: GENERIC STANDARDS - EMISSION STANDARD FOR INDUSTRIAL ENVIRONMENTS |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
EN 50121-2:2017 | Railway applications - Electromagnetic compatibility - Part 2: Emission of the whole railway system to the outside world |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
EN 61000-3-12:2011 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-12: LIMITS - LIMITS FOR HARMONIC CURRENTS PRODUCED BY EQUIPMENT CONNECTED TO PUBLIC LOW-VOLTAGE SYSTEMS WITH INPUT CURRENT > 16 A AND <= 75 A PER PHASE (IEC 61000-3-12:2011) |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
IEC 61000-4-18:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test |
EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.