EN 50298:1998
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements
12-12-2003
20-10-1998
1 General
1.1 Scope and object
1.2 Normative references
2 Definitions
2.1 Empty enclosure
2.2 Protected space
2.3 Cover
2.4 Door
2.5 Mounting plate
2.6 Cable gland plate
2.7 Removable cover
2.8 Enclosure manufacturer
2.9 Box
2.10 Cubicle
3 Classification
3.1 The type of material
3.2 The method of fixing
3.3 The intended location
3.4 The degree of protection
3.5 The rated insulation voltage (for enclosures made
of insulating materials)
4 EMC requirements
5 Information to be given regarding the enclosure
5.1 Marking
5.2 Documentation
6 Service conditions
6.1 Normal service conditions
6.2 Special service conditions
6.3 Conditions during transport and storage
7 Design and construction
7.1 General
7.2 Dimensions
7.3 Mounting arrangements
7.4 Static loads
7.5 Lifting and transport support
7.6 Access to the interior of the enclosure
7.7 Protective circuit
7.8 Dielectric strength
7.9 Degree of protection (IK code)
7.10 Degree of protection (IP code)
8 Type tests
8.1 General conditions of tests
8.2 Marking
8.3 Static loads
8.4 Lifting
8.5 Verification of axial loads of metal inserts
8.6 Verification of degree of protection against
external mechanical impacts (IK code)
8.7 Verification of degree of protection (IP code)
8.8 Properties of insulating materials
8.9 Verification of the dielectric strength
8.10 Verification of the continuity of the protective
circuit
8.11 Verification of resistance to weathering
8.12 Verification of resistance to corrosion
The object of this standard is to specify definitions, classifications, characteristics and test requirements of enclosures to be used as part of switchgear and controlgear assemblies in accordance with the EN 60439 series, the rated voltage of which does not exceed 1 000 V a.c. at frequencies not exceeding 1 000 Hz, or 1 500 V d.c. and suitable for general use for either indoor or outdoor applications. This standard applies to empty enclosures, prior to the incorporation of switchgear and controlgear components by the user, as supplied by the enclosure manufacturer. This standard does not apply to enclosures which are covered by other specific products standards (e.g. IEC 60670, household and similar installations). Compliance with the safety requirements of the applicable product standard is the responsibility of the final assembly manufacturer. This standard may serve as a basis for other technical committees
Committee |
CLC/TC 17D
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
DIN EN 50298 : 1999 | Identical |
UNE-EN 50298:1999 | Identical |
CEI EN 50298 : 1ED 1999 | Identical |
NEN EN 50298 : 1998 | Identical |
NBN EN 50298 : 1999 | Similar to |
SN EN 50298 : 1998 | Identical |
I.S. EN 50298:1999 | Identical |
BS EN 50298:1999 | Identical |
NF EN 50298 : 1999 | Identical |
VDE 0660-511 : 2012 | Identical |
EN 60695-2-1-1 : 1996 | FIRE HAZARD TESTING - TEST METHODS - GLOW-WIRE END-PRODUCT TEST AND GUIDANCE |
HD 528 : 200S2 | A METHOD OF TEMPERATURE-RISE ASSESSMENT BY EXTRAPOLATION FOR PARTIALLY TYPE-TESTED ASSEMBLIES (PTTA) OF LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
ISO 11469:2016 | Plastics — Generic identification and marking of plastics products |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
EN 50102:1995/corrigendum Jul. 2002 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES FOR ELECTRICAL EQUIPMENT AGAINST EXTERNAL MECHANICAL IMPACTS (IK CODE) |
EN 60439-5:2006 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 5: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR POWER DISTRIBUTION IN PUBLIC NETWORKS |
ISO 4628-3:2016 | Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 3: Assessment of degree of rusting |
EN 60695-2-1-0 : 1996 | FIRE HAZARD TESTING - TEST METHODS - GLOW-WIRE TEST METHODS - GENERAL |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60439-1:1999/A1:2004 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60670:1989+AMD1:1994 CSV | General requirements for enclosures for accessories for household and similar fixed electrical installations |
ISO 179:1993 | Plastics Determination of Charpy impact strength |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 2409:2013 | Paints and varnishes Cross-cut test |
ISO 178:2010 | Plastics Determination of flexural properties |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.