
EN 60947-5-2:2007/A1:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by

LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-2: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - PROXIMITY SWITCHES (IEC 60947-5-2:2007/A1:2012)
07-04-2020
12-01-2013
1 General
2 Definitions
3 Classification
4 Characteristics
5 Product information
6 Normal service, mounting and transport conditions
7 Constructional and performance requirements
8 Tests
Annex A (informative) Typical dimensions and operating
distances of proximity switches
Annex B (normative) - Class II proximity switches insulated
by encapsulation - Requirements and tests
Annex C (normative) - Additional requirements for proximity
switches with integrally connected cables
Annex D (normative) - Integral connectors for plug-in
proximity switches
Annex E (normative) - Additional requirements for proximity
switches suitable for use in strong magnetic fields
Annex F (informative) - Symbols for proximity switches
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Annex ZZ (informative) - Coverage of Essential Requirements
of EC Directives
Pertains to inductive and capacitive proximity switches that sense the presence of metallic and/or non-metallic objects, ultrasonic proximity switches that sense the presence of sound reflecting objects, photoelectric proximity switches that sense the presence of objects and non-mechanical magnetic proximity switches that sense the presence of objects with a magnetic field.
Committee |
TC 17B
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
CEI EN 60947-5-2/A1:2013 | Identical |
OVE/ONORM EN 60947-5-2 : 2014 | Identical |
NF EN 60947 5-2 : 2008 AMD 1 2013 | Identical |
IEC 60947-5-2:2007+AMD1:2012 CSV | Identical |
NBN EN 60947 5-2 : 2008 AMD 1 2013 | Identical |
NEN EN IEC 60947-5-2 : 2008 AMD 1 2012 | Identical |
I.S. EN 60947-5-2:2008 | Identical |
PN EN 60947-5-2 : 2011 AMD 1 2013 | Identical |
SN EN 60947-5-2 : 1998 AMD 1 1999 | Identical |
DIN EN 60947-5-2 : 2014-01 | Identical |
VDE 0660-208 : 2014 | Identical |
UNE-EN 60947-5-2:2008 | Identical |
BS EN 60947-5-2 : 2007 | Identical |
BS EN 60947-5-2:2007+A1:2012 | Identical |
BS EN 55016-1-6:2015+A2:2022 | Identical |
UNE-EN 60947-5-3:2014 | Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
DIN EN 50319 : 2000 | PROXIMITY DEVICES - REQUIREMENTS FOR PROXIMITY DEVICES WITH ANALOGUE OUTPUT |
BS EN 60947-5-3:2013 | Low-voltage switchgear and controlgear Control circuit devices and switching elements. Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
CEI EN 60947-5-3 : 2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDDB) |
BS EN 60947-5-7:2003 | Specification for low-voltage switchgear and controlgear. Control circuit devices and switching elements Requirements for proximity devices with analogue output |
VDE 0660-212 : 2000 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-6: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - DC INTERFACE FOR PROXIMITY SENSORS AND SWITCHING AMPLIFIERS (NAMUR) |
I.S. EN 60947-5-9:2007 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-9: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - FLOW RATE SWITCHES |
DIN EN 60947-5-6 : 2000 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-6: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS, DC INTERFACE FOR PROXIMITY SENSORS AND SWITCHING AMPLIFIERS (NAMUR) |
BS EN 62026-2:2013 | Low-voltage switchgear and controlgear. Controller-device interfaces (CDIs) Actuator sensor interface (AS-i) |
BS EN 62026-3:2015 | Low-voltage switchgear and controlgear. Controller-device interfaces (CDIs) DeviceNet |
EN 61131-2:2007 | Programmable controllers - Part 2: Equipment requirements and tests |
EN 62683:2015 | Low-voltage switchgear and controlgear - Product data and properties for information exchange |
03/102595 DC : 0 | BS EN 14637 - BUILDING HARDWARE - ELECTRICALLY CONTROLLED HOLD-OPEN SYSTEMS FOR FIRE/SMOKE DOOR ASSEMBLIES - REQUIREMENTS, TEST METHODS, APPLICATION AND MAINTENANCE |
BS EN 50295:1999 | Low-voltage switchgear and controlgear. Controller and device interface systems. Actuator sensor interface (AS-i) |
BS EN 50227:1999 | Control circuit devices and switching elements proximity sensors, d.c. interface for proximity sensors and switching amplifiers (NAMUR) |
I.S. EN 50325-1:2002 | INDUSTRIAL COMMUNICATIONS SUBSYSTEM BASED ON ISO 11898 (CAN) FOR CONTROLLER-DEVICE INTERFACES - PART 1: GENERAL REQUIREMENTS |
CEI EN 61131-9 : 2014 | PROGRAMMABLE CONTROLLERS - PART 9: SINGLE-DROP DIGITAL COMMUNICATION INTERFACE FOR SMALL SENSORS AND ACTUATORS (SDCI) |
EN 62026-3:2015 | Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 3: DeviceNet |
BS EN 61131-2:2007 | Programmable controllers Equipment requirements and tests |
I.S. EN 62026-2:2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I) (IEC 62026-2:2008 (MOD)) |
CEI EN 60947-5-9 : 2008 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-9: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - FLOW RATE SWITCHES |
EN 303 446-2 : 1.1.0 DRAFT | ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR COMBINED AND/OR INTEGRATED RADIO AND NON-RADIO EQUIPMENT; PART 2: SPECIFIC CONDITIONS FOR EQUIPMENT INTENDED TO BE USED IN INDUSTRIAL LOCATIONS; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.1(B) OF DIRECTIVE 2014/53/EU |
BS EN 50325-2:2001 | Industrial communication subsystem based on ISO 11898 (CAN) for controller-device interfaces DeviceNet |
BS EN 50325-1:2002 | Industrial communication subsystem based on ISO 11898 (CAN) for controller-device interfaces General requirements |
I.S. EN 60947-5-3:2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-3: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH DEFINED BEHAVIOUR UNDER FAULT CONDITIONS (PDDB) |
CEI EN 60947-5-7 : 2005 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-7: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH ANALOGUE OUTPUT |
CEI EN 62026-2 : 2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONTROLLER-DEVICE INTERFACES (CDIS) - PART 2: ACTUATOR SENSOR INTERFACE (AS-I) |
BS EN 60947-5-6:2001 | Specification for low-voltage switchgear and controlgear. Control circuit devices and switching elements DC interface for proximity sensors and switching amplifiers (NAMUR) - DC interface for proximity sensors and switching amplifiers (NAMUR) |
BS EN 62683:2015 | Low-voltage switchgear and controlgear. Product data and properties for information exchange |
EN 62026-2:2013 | Low-voltage switchgear and controlgear - Controller-device interfaces (CDIs) - Part 2: Actuator sensor interface (AS-i) |
EN 50325-1:2002 | Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 1: General requirements |
EN 50319:1999 | Proximity devices - Requirements for proximity devices with analogue output |
BS EN 61131-9:2013 | Programmable controllers Single-drop digital communication interface for small sensors and actuators (SDCI) |
BS EN 50319:1999 | Proximity devices. Requirements for proximity devices with analogue output |
CEI EN 60947-5-6 : 2000 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-6: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS DC INTERFACE FOR PROXIMITY SENSORS AND SWITCHING AMPLIFIERS (NAMUR) |
BS EN 60947-5-9:2007 | Low-voltage switchgear and controlgear Control circuit devices and switching elements. Flow rate switches |
I.S. EN 60947-5-7:2003 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 5-7: CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS - REQUIREMENTS FOR PROXIMITY DEVICES WITH ANALOGUE OUTPUT |
I.S. EN 61131-9:2013 | PROGRAMMABLE CONTROLLERS - PART 9: SINGLE-DROP DIGITAL COMMUNICATION INTERFACE FOR SMALL SENSORS AND ACTUATORS (SDCI) |
I.S. EN 61131-2:2007 | PROGRAMMABLE CONTROLLERS - PART 2: EQUIPMENT REQUIREMENTS AND TESTS |
EN 60947-5-7:2003 | Low-voltage switchgear and controlgear - Part 5-7: Control circuit devices and switching elements - Requirements for proximity devices with analogue output |
EN 50295:1999 | Low-voltage switchgear and controlgear - Controller and device interface systems - Actuator Sensor interface (AS-i) |
EN 60947-5-3:2013 | Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB) |
EN 60947-5-6:2000 | Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR) |
EN 50325-2:2000 | Industrial communications subsystem based on ISO 11898 (CAN) for controller-device interfaces - Part 2: DeviceNet |
EN 60947-5-9:2007 | Low-voltage switchgear and controlgear - Part 5-9: Control circuit devices and switching elements - Flow rate switches |
EN 50227:1997 | Control circuit devices and switching elements proximity sensors, d.c. interface for proximity sensors and switching amplifiers (NAMUR) |
EN 61131-9 : 2013 | Programmable controllers - Part 9: Single-drop digital communication interface for small sensors and actuators (SDCI) |
EN 60446:2007 | Basic and safety principles for man-machine interface, marking and identification - Identification of conductors by colours or alphanumerics |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 61000-3-3:2013 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013) |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
EN 60947-1:2007/A2:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 1: GENERAL RULES (IEC 60947-1:2007/A2:2014) |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
EN 61000-4-8:2010 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
EN 61000-3-2:2014 | Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase) |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
EN 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
EN 61000-4-13:2002/A2:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015) |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.