I.S. EN 60439-5:2006
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 5: PARTICULAR REQUIREMENTS FOR ASSEMBLIES FOR POWER DISTRIBUTION IN PUBLIC NETWORKS
Hardcopy , PDF
01-02-2011
English
01-01-2006
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
1 General
2 Definitions
3 Classification of ASSEMBLIES
4 Electrical characteristics of ASSEMBLIES
5 Information to be given regarding the ASSEMBLY
6 Service conditions
7 Design and construction
8 Test specifications
Annex A (normative) Minimum and maximum cross-section
of copper and aluminium conductors, suitable
for connection
Annex ZA (normative) Normative references to
international publications with their
corresponding European publications
Annex ZB (informative) A-deviations
Provides supplementary requirements for substation cable distribution boards (SCDBs) and cable distribution cabinets (CDCs), which are stationary, type-tested assemblies (TTA).
DevelopmentNote |
Supersedes I.S. EN 50300. (12/2006)
|
DocumentType |
Standard
|
Pages |
74
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
IEC 60439-5:2006 | Identical |
BS EN 60439-5:2006 | Identical |
UNE-EN 60439-5:2007 | Identical |
NBN EN 60439-5 : 2007 | Identical |
SN EN 60439-5 : 2006 | Identical |
DIN EN 60439-5 : 2007 | Identical |
EN 60439-5:2006 | Identical |
NF EN 60439-5 : 2007 | Identical |
EN 60446:2007 | Basic and safety principles for man-machine interface, marking and identification - Identification of conductors by colours or alphanumerics |
ISO 9223:2012 | Corrosion of metals and alloys — Corrosivity of atmospheres — Classification, determination and estimation |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
EN ISO 6506-1:2014 | Metallic materials - Brinell hardness test - Part 1: Test method (ISO 6506-1:2014) |
ISO 6506-1:2014 | Metallic materials Brinell hardness test Part 1: Test method |
EN 60238 : 2004 AMD 2 2011 | EDISON SCREW LAMPHOLDERS (IEC 60238:2004/A2:2011) |
EN ISO 3231:1997 | Paints and varnishes - Determination of resistance to humid atmospheres containing sulfur dioxide (ISO 3231:1993) |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
ISO 4628-3:2016 | Paints and varnishes — Evaluation of degradation of coatings — Designation of quantity and size of defects, and of intensity of uniform changes in appearance — Part 3: Assessment of degree of rusting |
EN ISO 4628-3:2016 | Paints and varnishes - Evaluation of degradation of coatings - Designation of quantity and size of defects, and of intensity of uniform changes in appearance - Part 3: Assessment of degree of rusting (ISO 4628-3:2016) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 60439-1:1999+AMD1:2004 CSV | Low-voltage switchgear and controlgear assemblies - Part 1: Type-tested and partially type-tested assemblies |
EN 60439-1:1999/A1:2004 | LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
EN 60068-2-11:1999 | Environmental testing - Part 2: Tests - Test Ka: Salt mist |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
EN 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
EN ISO 4892-2:2013 | Plastics - Methods of exposure to laboratory light sources - Part 2: Xenon-arc lamps (ISO 4892-2:2013) |
EN 60269-1:2007/A2:2014 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006/A2:2014) |
ISO 3231:1993 | Paints and varnishes — Determination of resistance to humid atmospheres containing sulfur dioxide |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |