FOREWORD
0 Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviations
5 DLL - PhL interface
6 Systems management - PhL interface
7 DCE independent sublayer (DIS)
8 DTE - DCE interface and MIS-specific functions
9 Medium dependent sublayer (MDS)
10 MDS - MAU interface
11 Types 1 and 7: Medium attachment unit: voltage mode,
linear-bus-topology 150 Omega twisted-pair wire medium
12 Types 1 and 3: Medium attachment unit: 31,25 kbit/s,
voltage-mode with low-power option, bus- and
tree-topology, 100 Omega wire medium
13 Type 1: Medium attachment unit: current mode,
twisted-pair wire medium
14 Type 1: Medium attachment unit: current mode (1 A),
twisted-pair wire medium
15 Types 1 and 7: Medium attachment unit: dual-fiber
optical media
16 Type 1: Medium attachment unit: 31,25 kbit/s,
single-fiber optical medium
17 Void
18 Type 2: Medium attachment unit: 5 Mbit/s,
voltage-mode, coaxial wire medium
19 Type 2: Medium attachment unit: 5 Mbit/s,
optical medium
20 Type 2: Medium attachment unit: network access
port (NAP)
21 Type 3: Medium attachment unit: synchronous
transmission, 31,25 kbit/s, voltage mode,
wire medium
22 Type 3: Medium attachment unit: asynchronous
transmission, wire medium
23 Type 3: Medium attachment unit: asynchronous
transmission, optical medium
24 Type 4: Medium attachment unit: RS-485
25 Void
26 Void
27 Type 8: Medium attachment unit: twisted-pair
wire medium
28 Type 8: Medium attachment unit: optical media
29 Type 12: Medium attachment unit: electrical medium
30 Type 16: Medium attachment unit: optical fiber
medium at 2, 4, 8 and 16 Mbit/s
31 Type 18: Medium attachment unit: basic medium
32 Type 18: Medium attachment unit: powered medium
33 Type 24: Medium attachment unit: twisted-pair wire medium
34 Type 20: Medium attachment unit: FSK medium
Annex A (normative) - Type 1: Connector specification
Annex B (informative) - Types 1 and 3: Cable specifications and
trunk and spur lengths for the 31,25 kbit/s
voltage-mode MAU
Annex C (informative) - Types 1 and 7: Optical passive stars
Annex D (informative) - Types 1 and 7: Star topology
Annex E (informative) - Type 1: Alternate fibers
Annex F (normative) - Type 2: Connector specification
Annex G (normative) - Type 2: Repeater machine sublayers
(RM, RRM) and redundant PhLs
Annex H (informative) - Type 2: Reference design examples
Annex I (normative) - Type 3: Connector specification
Annex J (normative) - Type 3: Redundancy of PhL
and medium
Annex K (normative) - Type 3: Optical network topology
Annex L (informative) - Type 3: Reference design
examples for asynchronous transmission, wire
medium, intrinsically safe
Annex M (normative) - Type 8: Connector specification
Annex N (normative) - Type 16: Connector specification
Annex O (normative) - Type 16: Optical network topology
Annex P (informative) - Type 16: Reference design example
Annex Q (normative) - Type 18: Connector specification
Annex R (normative) - Type 18: Media cable specifications
Annex S (normative) - Type 24: Connector specification
Annex T (informative) - Type 20: Network topology, cable
characteristics and lengths, power distribution through
barriers, and shielding and grounding
Bibliography
Annex ZA (normative) - Normative references to
International publications with their
corresponding European publications
Describes the requirements for fieldbus component parts. It also specifies the media and network configuration requirements necessary to ensure agreed levels of: a) data integrity before data-link Layer error checking; b) interoperability between devices at the Physical Layer.
DevelopmentNote |
Supersedes I.S. EN 50170 and I.S. EN 50254 (09/2004) Supersedes I.S. EN 61491. (10/2009) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
1024
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
BS EN 61158-2:2014 | Identical |
EN 61158-2:2014 | Identical |
NF EN 61158-2 : 2015 | Identical |
SN EN 61158-2 : 2014 | Identical |
NBN EN 61158-2 : 2014 | Identical |
DIN EN 61158-2:2015-02 | Identical |
IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
ISO 4892-1:2016 | Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 61158-4-20:2014 | Industrial communication networks - Fieldbus specifications - Part 4-20: Data-link layer protocol specification - Type 20 elements |
IEC 61158-4-7:2007 | Industrial communication networks - Fieldbus specifications - Part 4-7: Data-link layer protocol specification - Type 7 elements |
EN 61754-2:1997 | Fibre optic connector interfaces - Part 2: Type BFOC/2,5 connector family |
IEC 61169-8:2007 | Radio-frequency connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristic impedance 50 Ω (type BNC) |
TIA/EIA 422 : B1994(R2014) | ELECTRICAL CHARACTERISTICS OF BALANCED VOLTAGE DIGITAL INTERFACE CIRCUITS |
IEC 61158-4-1:2014 | Industrial communication networks - Fieldbus specifications - Part 4-1: Data-link layer protocol specification - Type 1 elements |
IEC 60807-3:1990 | Rectangular connectors for frequencies below 3 MHz - Part 3: Detail specification for a range of connectors with trapezoidal shaped metal shells and round contacts - Removable crimp contact types with closed crimp barrels, rear insertion/rear extraction |
IEC 61784-1:2014 | Industrial communication networks - Profiles - Part 1: Fieldbus profiles |
ISO/IEC 7498-1:1994 | Information technology Open Systems Interconnection Basic Reference Model: The Basic Model |
EN 60754-2:2014 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
EN ISO 4892-1:2016 | Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (ISO 4892-1:2016) |
IEC 60189-1:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 61754-22:2005 | Fibre optic connector interfaces - Part 22: Type F-SMA connector family |
EN 61131-2:2007 | Programmable controllers - Part 2: Equipment requirements and tests |
ISO/IEC 8886:1996 | Information technology Open Systems Interconnection Data link service definition |
IEC 60793-2-30:2015 | Optical fibres - Part 2-30: Product specifications - Sectional specification for category A3 multimode fibres |
EN 61754-22:2005 | Fibre optic connector interfaces - Part 22: Type F-SMA connector family |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
EN 61754-13:2006 | Fibre optic connector interfaces - Part 13: Type FC-PC connector |
IEC 61596:1995 | Magnetic oxide EP-cores and associated parts for use in inductors and transformers - Dimensions |
IEC 60794-1-2:2017 | Optical fibre cables - Part 1-2: Generic specification - Basic optical cable test procedures - General guidance |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
EN 60793-2-40:2016 | Optical fibres - Part 2-40: Product specifications - Sectional specification for category A4 multimode fibres |
EN 61169-8:2007 | Radio-frequency connectors - Part 8: Sectional specification - RF coaxial connectors with inner diameter of outer conductor 6,5 mm (0,256 in) with bayonet lock - Characteristic impedance 50 ohms (type BNC) |
IEC 60793-2-40:2015 | Optical fibres - Part 2-40: Product specifications - Sectional specification for category A4 multimode fibres |
IEC 61158-4-12:2014 | Industrial communication networks - Fieldbus specifications - Part 4-12: Data-link layer protocol specification - Type 12 elements |
ISO/IEC 8802-3:2000 | Information technology Telecommunications and information exchange between systems Local and metropolitan area networks Specific requirements Part 3: Carrier sense multiple access with collision detection (CSMA/CD) access method and physical layer specifications |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
ISO/IEC 10731:1994 | Information technology Open Systems Interconnection Basic Reference Model Conventions for the definition of OSI services |
EN 61158-4-3:2014 | Industrial communication networks - Fieldbus specifications - Part 4-3: Data-link layer protocol specification - Type 3 elements |
IEC 61754-2:1996 | Fibre optic connector interfaces - Part 2: Type BFOC/2,5 connector family |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60079-11:2012 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 61754-13:2006 | Fibre optic connector interfaces - Part 13: Type FC-PC connector |
EN 60079-25:2010/AC:2013 | EXPLOSIVE ATMOSPHERES - PART 25: INTRINSICALLY SAFE ELECTRICAL SYSTEMS (IEC 60079-25:2010) |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60793-2-30:2015 | Optical fibres - Part 2-30: Product specifications - Sectional specification for category A3 multimode fibres |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
EN 61158-4-2:2014 | Industrial communication networks - Fieldbus specifications -Part 4-2: Data-link layer protocol specification - Type 2 elements |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60079-25:2010 | Explosive atmospheres - Part 25: Intrinsically safe electrical systems |
IEC 61300-3-4:2012 | Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-4: Examinations and measurements - Attenuation |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
ISO/IEC 10022:1996 | Information technology Open Systems Interconnection Physical Service Definition |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
EN 61158-3-20:2014 | Industrial communication networks - Fieldbus specifications - Part 3-20: Data-link layer service definition - Type 20 elements |
IEC 61158-4-3:2014 | Industrial communication networks - Fieldbus specifications - Part 4-3: Data-link layer protocol specificationn - Type 3 elements |
EN 60794-1-2:2017/AC:2017-07 | OPTICAL FIBRE CABLES - PART 1-2: GENERIC SPECIFICATION - BASIC OPTICAL CABLE TEST PROCEDURES - GENERAL GUIDANCE (IEC 60794-1-2:2017) |
TIA/EIA 644 : A2001(R2012) | ELECTRICAL CHARACTERISTICS OF LOW VOLTAGE DIFFERENTIAL SIGNALING (LVDS) INTERFACE CIRCUITS |
IEC TR 61491:2010 | Electrical equipment of industrial machines - Serial data link for real-time communication between controls and drives |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
EN 60811-404:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths |
EN 60811-403:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds |
IEC 60811-404:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 61158-4-18:2010 | Industrial communication networks - Fieldbus specifications - Part 4-18: Data-link layer protocol specification - Type 18 elements |
IEC 61131-2:2017 | Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
IEC 60947-5-2:2007+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches |
EN 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
TIA 485 : A1998(R2012) | ELECTRICAL CHARACTERISTICS OF GENERATORS AND RECEIVERS FOR USE IN BALANCED DIGITAL MULTIPOINT SYSTEMS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO/IEC 8482:1993 | Information technology Telecommunications and information exchange between systems Twisted pair multipoint interconnections |
IEC 61158-4-8:2007 | Industrial communication networks - Fieldbus specifications - Part 4-8: Data-link layer protocol specification - Type 8 elements |
IEC 60875-1:2015 | Fibre optic interconnecting devices and passive components - Non-wavelength-selective fibre optic branching devices - Part 1: Generic specification |
IEC 60227-5:2011 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords) |
IEC 61158-3-20:2014 | Industrial communication networks - Fieldbus specifications - Part 3-20: Data-link layer service definition - Type 20 elements |
IEC 61784-2:2014 | Industrial communication networks - Profiles - Part 2: Additional fieldbus profiles for real-time networks based on ISO/IEC 8802-3 |
IEC 61158-4-16:2007 | Industrial communication networks - Fieldbus specifications - Part 4-16: Data-link layer protocol specification - Type 16 elements |
IEC 60811-403:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds |
IEC 60603-7-4:2010 | Connectors for electronic equipment - Part 7-4: Detail specification for 8-way, unshielded, free and fixed connectors, for data transmissions with frequencies up to 250 MHz |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.