I.S. EN 61204:1996
Current
The latest, up-to-date edition.
LOW-VOLTAGE POWER SUPPLY DEVICES, D.C. OUTPUT - PERFORMANCE CHARACTERISTICS
Hardcopy , PDF
English
01-01-1996
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
FOREWORD
INTRODUCTION
1 General
1.1 Scope and object
1.2 Normative references
1.3 Definitions
2 Presentation of performance characteristics
3 Performance
3.1 Rated outputs and total output power
3.2 Ambient operation temperature range
3.3 Ambient storage and transit temperature range
3.4 Source voltage and frequency
3.5 Source current
3.6 Source effect (source regulation)
3.7 Load effect (load regulation)
3.8 Output voltage tolerance (intrinsic error) - fixed
outputs
3.9 Adjustability of output voltage
3.10 Periodic and random deviation
3.11 Interaction effects (cross regulation)
3.12 Temperature coefficient
3.13 Hold-up time (turn-off delay time)
3.14 Start-up time (turn-on delay time)
3.15 Turn-on (turn-off) overshoot
3.16 Transient response to load current changes
3.17 Output overvoltage protection
3.18 Output overcurrent protection
3.19 Mean time between failures (MTBF)
4 Requirements for safety
4.1 General
4.2 Creepage distances, clearances and distances through
insulation
4.3 Electric strength
4.4 Earth leakage current
4.5 Flammability
4.6 Thermal requirements
4.7 Protective devices
5 Interference requirements
5.1 Noise level
5.2 Conducted EMI
5.3 Radiated EMI (magnetic component)
5.4 Input transient voltage
6 Additional requirements
6.1 Remote programming (remote control)
6.2 Remote sensing
6.3 Mechanical characteristics
6.4 Series operation
6.5 Parallel operation
6.6 Monitoring and control signals
7 Test requirements
7.1 General
7.2 Environmental tests
8 Miscellaneous requirements
8.1 Markings and instructions
Annexes
A - Periodic and random deviation test methods
B - Output overvoltage protection
C - Overcurrent protection characteristics
D - Parallel operation
ANNEX ZA (normative) OTHER INTERNATIONAL PUBLICATIONS
QUOTED IN THIS STANDARD WITH THE REFERENCE OF THE
RELEVANT EUROPEAN PUBLICATIONS
Describes a method of specifying requirements for low-voltage power supply devices (including switching types) providing d.c. output(s) up to 200 V d.c. at a power level up to 30 kW, operating from a.c. or d.c. source voltages of up to 600 V.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
86
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
SN EN 61204 : 1995 AMD 1 2001 | Identical |
IEC 61204:1993+AMD1:2001 CSV | Identical |
DIN EN 61204 : 2001 | Identical |
EN 61204:1995/A1:2001 | Identical |
NBN EN 61204 : 2000 AMD 1 2001 | Identical |
NF EN 61204 : 1995 AMD 1 2001 | Identical |
BS EN 61204:1995 | Identical |
UNE-EN 61204:1998 | Identical |
IEC 60038:2009 | IEC standard voltages |
EN 60721-3-1:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 1: Storage |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60950:1999 | Safety of information technology equipment |
EN 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60950:2000/corrigendum:2002 | SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT |
IEC 60801-4:1988 | Electromagnetic compatibility for industrial-process measurement and control equipment - Part 4: Electrical fast transient/burst requirements |
IEC 60478-1:1974 | Stabilized power supplies, d.c. output. Part 1: Terms and definitions |
HD 472 S1:1989/AC:2013 | NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS |
EN 60068-2-27:2009 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
HD 323.2.3 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST CA - DAMP HEAT, STEADY STATE |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
MIL-HDBK-217 Revision F:1991 | RELIABILITY PREDICTION OF ELECTRONIC EQUIPMENT |
HD 323.2.6 : 200S2 | BASIC ENVIRONMENTAL TESTING PROCEDURES - TESTS - TEST FC AND GUIDANCE: VIBRATION (SINUSOIDAL) |
IEC 60478-2:1986 | Stabilized power supplies, d.c. output. Part 2: Rating and performance |
IEC 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
EN 60068-2-29:1993 | Environmental testing - Part 2: Tests - Test Eb and guidance: Bump |
IEC 60478-5:1993 | Stabilized power supplies, d.c. output - Part 5: Measurement of the magnetic component of the reactive near field |
IEC 60478-4:1976 | Stabilized power supplies, d.c. output. Part 4: Tests other than radio-frequency interference |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
EN 60651:1994/A2:2001 | SOUND LEVEL METERS (IEC 60651:1979/A2:2000) |
EN 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60651:1979+AMD1:1993+AMD2:2000 CSV | Sound level meters |
IEC 60478-3:1989 | Stabilized power supplies, d.c. output. Part 3: Reference levels and measurement of conducted electromagnetic interference (EMI) |
IEC 60721-3-1:1997 | Classification of environmental conditions - Part 3 Classification of groups of environmental parameters and their severities - Section 1: Storage |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.