I.S. EN ISO 80079-36:2016
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
EXPLOSIVE ATMOSPHERES - PART 36: NON-ELECTRICAL EQUIPMENT FOR EXPLOSIVE ATMOSPHERES - BASIC METHOD AND REQUIREMENTS (ISO/DIS 80079-36:2014)
Hardcopy , PDF
English
01-01-2016
11-01-2020
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Dates of withdrawal of national standards are available from NSAI.
National Foreword
European Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 EPL and equipment groups
5 Ignition hazard assessment
6 Assessment of possible ignition sources and control means
7 Additional considerations
8 Verification and tests
9 Documentation
10 Instructions
11 Marking
Annex A (informative) - Methodology for confirming the EPL
Annex B (informative) - Explanation of the ignition
hazard assessment procedure
Annex C (informative) - Examples of ignition hazard
assessment
Annex D (normative) - Charging tests with non-conductive
materials
Annex E (informative) - Consideration of misuse which
can reasonably be anticipated during ignition hazard
assessment procedure
Annex F (informative) - Development of different types
of incendive electrostatic discharges
Annex G (normative) - Protection concepts of types of
protection 'd', 'p' and 't' acceptable for
non-electrical equipment
Annex H (informative) - Volume dependence of
auto-ignition temperature
Annex I (informative) - Relationship between Equipment
protection levels (EPLs) and zones
Bibliography
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements
of EU Directive 2014/34/EU
Annex ZB (informative) - Correspondence of equipment groups
Annex ZC (informative) - Significant changes between this
European Standard and EN 13463-1:2009
Gives the basic method and requirements for design, construction, testing and marking of non-electrical Ex equipment, Ex Components, protective systems, devices and assemblies of these products that have their own potential ignition sources and are intended for use in explosive atmospheres.
| DevelopmentNote |
Supersedes I.S. EN 13463-1. (05/2016)
|
| DocumentType |
Standard
|
| Pages |
194
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| EN ISO 80079-36:2016 | Identical |
| ISO 80079-36:2016 | Identical |
| IEC 61025:2006 | Fault tree analysis (FTA) |
| ISO 6507-1:2005 | Metallic materials — Vickers hardness test — Part 1: Test method |
| EN 1127-1:2011 | Explosive atmospheres - Explosion prevention and protection - Part 1: Basic concepts and methodology |
| IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
| ISO 6507-4:2005 | Metallic materials — Vickers hardness test — Part 4: Tables of hardness values |
| IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
| IEC 60079-10-1:2015 | Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres |
| EN 13237:2012 | Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
| IEC 60079-20-1:2010 | Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
| ISO 12100:2010 | Safety of machinery — General principles for design — Risk assessment and risk reduction |
| ISO 281:2007 | Rolling bearings — Dynamic load ratings and rating life |
| ISO/IEC 80079-38:2016 | Explosive atmospheres — Part 38: Equipment and components in explosive atmospheres in underground mines |
| EN 1755:2015 | Industrial Trucks - Safety requirements and verification - Supplementary requirements for operation in potentially explosive atmospheres |
| EN 15198:2007 | Methodology for the risk assessment of non-electrical equipment and components for intended use in potentially explosive atmospheres |
| ISO 80079-37:2016 | Explosive atmospheres — Part 37: Non-electrical equipment for explosive atmospheres — Non-electrical type of protection constructional safety 'c', control of ignition sources 'b', liquid immersion 'k' |
| IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
| ISO 16852:2016 | Flame arresters — Performance requirements, test methods and limits for use |
| IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
| IEC 60079-31:2013 | Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
| IEC 60079-26:2014 RLV | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
| CLC/TR 50404:2003 | Electrostatics - Code of practice for the avoidance of hazards due to static electricity |
Access your standards online with a subscription
-