IEC 60092-350:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
English - French, Spanish, Castilian
12-08-2014
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Construction requirements
5 Test methods
6 Sample tests
7 Type tests, electrical
8 Type tests, non-electrical
Annex A (normative) - Fictitious calculation method for
determination of dimensions of protective coverings
Annex B (informative) - Recommended minimum spark test
voltage levels (according to IEC 62230)
Annex C (normative) - Rounding of numbers
Annex D (normative) - Calculation of the lower and upper
limits for the outer dimensions of cables with
circular copper conductors
Annex E (normative) - Cold bend test and impact test for
low temperature behaviour
Bibliography
IEC 60092-350:2014 provides the general constructional requirements and test methods for use in the manufacture of electric power, control and instrumentation cables with copper conductors intended for fixed electrical systems at voltages up to and including 18/30(36) kV on board ships and offshore (mobile and fixed) units. The following types of cables are not included:
- optical fibre;
- sub-sea and umbilical cables;
- data and communication cables;
- coaxial cables. This edition includes the following significant technical changes with respect to the previous edition:
a) reference to IEC 60092-360 for both the insulating and sheathing compounds;
b) partial discharge tests have been transferred from IEC 60092-354 to align it with IEC 60092-353;
c) requirements for oil and drilling-fluid resistance (former Annexes F and G) have been transferred to IEC 60092-360;
d) requirements for cold bending and shocks have been improved;
e) the document reflects the changes of material types that have been introduced during the development of IEC 60092-353 and IEC 60092-360.
The contents of the corrigendum of November 2018 have been included in this copy.
Committee |
TC 18/SC 18A
|
DevelopmentNote |
Supersedes IEC 60092-3. (03/2010) Stability Date: 2018. (08/2014)
|
DocumentType |
Standard
|
ISBN |
978-2-8322-1786-3
|
Pages |
111
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
AS/NZS IEC 60092.350:2019 | Identical |
UNE-IEC 60092-350:2015 | Identical |
NEN IEC 60092-350 : 2014 | Identical |
UNE 21135-350:2002 | Identical |
BS EN 60601-1-2:2007 | Identical |
16/30337938 DC : 0 | BS EN 80005-1 - UTILITY CONNECTIONS IN PORT - HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - PART 1: GENERAL REQUIREMENTS |
BS EN ISO 10133:2017 | Small craft. Electrical systems. Extra-low-voltage d.c. installations |
CEI EN 60092-507 : 2016 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS |
12/30260078 DC : 0 | BS EN 60092-502 IEC 60092-502 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 502: TANKERS - SPECIAL FEATURES |
BS EN 60092-507:2015 | Electrical installations in ships Small vessels |
09/30196635 DC : 0 | BS EN 60092-510 - ELECTRICAL INSTALLATIONS IN SHIPS - SPECIAL FEATURES - HIGH VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS) |
CEI 18-52 : 2013 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 354: SINGLE- AND THREE-CORE POWER CABLES WITH EXTRUDED SOLID INSULATION FOR RATED VOLTAGES 6 KV (U[M] = 7,2 KV) UP TO 30 KV (U[M] = 36 KV) |
UNE-IEC 60092-360:2015 | Electrical installations in ships - Part 360: Insulating and sheathing materials for shipboard and offshore units, power, control, instrumentation and telecommunication cables |
CEI 18-64 : 2008 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES |
ISO 10133:2012 | Small craft Electrical systems Extra-low-voltage d.c. installations |
BS ISO 14885:2014 | Large yachts. Diesel engines for main propulsion and essential auxiliaries. Safety requirements |
12/30259316 DC : 0 | BS ISO 14885 - SHIPS AND MARINE TECHNOLOGY - LARGE YACHTS - AUXILIARY DIESEL ENGINES - SAFETY REQUIREMENTS |
BS IEC 60092-502:1999 | Electrical installation in ships Tankers. Special features |
BS IEC 60533:2015 | Electrical and electronic installations in ships. Electromagnetic compatibility (EMC). Ships with a metallic hull |
IEC 60092-354:2014 | Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
I.S. EN 60092-507:2015 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS |
ASTM F 1883 : 2003 : R2008 | Standard Practice for Selection of Wire and Cable Size in AWG or Metric Units |
IEC 60092-353:2016 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
IEC 60533:2015 | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
IEC 60092-503:2007 | Electrical installations in ships - Part 503: Special features - AC supply systems with voltages in the range of above 1 kV up to and including 15 kV |
IEC 60092-376:2017 RLV | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
BS 6883:1999 | Elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units. Requirements and test methods |
VDE 0129-507 : 2001 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: PLEASURE CRAFT (IEC 60092-507:2000) |
07/30167170 DC : 0 | BS EN ISO 10133 - SMALL CRAFT - ELECTRICAL SYSTEMS - EXTRA-LOW-VOLTAGE D.C. INSTALLATIONS |
UNE-IEC 60092-353:2017 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
IEC 60092-352:2005 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
BS IEC 61892-6:2013 | Mobile and fixed offshore units. Electrical installations Installation |
IEC PAS 60092-510:2009 | Electrical installations in ships - Part 510: Special features - High-voltage shore connection systems |
IEC 60092-502:1999 | Electrical installations in ships - Part 502: Tankers - Special features |
IEC TS 62100:2004 | Cables for aeronautical ground lighting primary circuits |
IEC 60092-201:1994 | Electrical installations in ships - Part 201: System design - General |
IEC 60092-507:2014 | Electrical installations in ships - Part 507: Small vessels |
I.S. EN ISO 10133:2017 | SMALL CRAFT - ELECTRICAL SYSTEMS - EXTRA-LOW-VOLTAGE D.C. INSTALLATIONS (ISO 10133:2012) |
12/30261012 DC : 0 | BS IEC 61892-6 - MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 6: INSTALLATION |
IEC 60092-353:2016 RLV | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
ASTM F 2363/F2363M : 2017 : REDLINE | Standard Specification for Sewage and Graywater Flow Through Treatment Systems |
BS ISO/IEC/IEEE 80005-1:2012 | Utility connections in port High Voltage Shore Connection (HVSC) Systems. General requirements |
BS IEC 60092-503:2007 | Electrical installations in ships Special features. AC supply systems with voltages in the range of above 1 kV up to and including 15 kV |
PD IEC/PAS 80005-3:2014 | Utility connections in port Low Voltage Shore Connection (LVSC) Systems. General requirements |
13/30283500 DC : 0 | BS EN 60533 ED 3.0 - ELECTRICAL AND ELECTRONIC INSTALLATIONS IN SHIPS - ELECTROMAGNETIC COMPATIBILITY |
ASTM F 1883 : 2003 | Standard Practice for Selection of Wire and Cable Size in AWG or Metric Units |
01/202703 DC : DRAFT APRIL 2001 | IEC 60092-354 ED.2 - ELECTRICAL INSULATION IN SHIPS - PART 354: SINGLE AND THREE CORE POWER CABLES WITH EXTRUDED SOLID INSULATION FOR RATED VOLTAGES 6 KV (UM EQUALS 7.2 KV) UP TO 30 KV (UM EQUALS 36 KV) |
ASTM F 1883 : 2003 : R2013 | Standard Practice for Selection of Wire and Cable Size in AWG or Metric Units |
IEC TR 60092-370:2009 | Electrical installations in ships - Part 370: Guidance on the selection of cables for telecommunication and data transfer including radio-frequency cables |
UNE-IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
ISO 14885:2014 | Large yachts Diesel engines for main propulsion and essential auxiliaries Safety requirements |
IEC PAS 80005-3:2014 | Utility connections in port - Part 3: Low Voltage Shore Connection (LVSC) Systems - General requirements |
EN 60092-507:2015/AC:2015 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS |
UNE-IEC 61892-4:2016 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
BS 8450:2006 | Code of practice for installation of electrical and electronic equipment in ships |
13/30292538 DC : 0 | BS EN 60092-507 ED 3.0 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS |
EN ISO 10133:2017 | Small craft - Electrical systems - Extra-low-voltage d.c. installations (ISO 10133:2012) |
DIN EN ISO 10133:2013-04 | Small craft - Electrical systems - Extra-low-voltage d.c. installations (ISO 10133:2012) |
UNE-IEC 60092-354:2015 | Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
UNE-IEC 60092-352:2015 | Electrical installations in ships - Part 352: Choice and installation of electrical cables |
IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC/ISO/IEEE 80005-1:2012 | Utility connections in port - Part 1: High Voltage Shore Connection (HVSC) Systems - General requirements |
IEC 61892-6:2013 | Mobile and fixed offshore units - Electrical installations - Part 6: Installation |
IEC 61892-4:2007 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
IEC 60533:2015 RLV | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
IEC 60811-501:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds |
IEC 60811-509:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test) |
IEC 60811-507:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials |
IEC 60811-506:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
IEC 60811-505:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths |
IEC 60331-2:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm |
IEC 60811-504:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths |
IEC 60331-11:1999+AMD1:2009 CSV | Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 °C |
AS/NZS IEC 60092.376:2020 | Electrical installations in ships Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 60811-203:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
IEC 60811-401:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven |
IEC 60811-409:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths |
IEC 60811-202:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non-metallic sheath |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60230:1966 | Impulse tests on cables and their accessories |
IEC 60092-353:2016 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
IEC 60811-508:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical tests - Pressure test at high temperature for insulation and sheaths |
AS/NZS IEC 60092.360:2020 | Electrical installations in ships Insulating and sheathing materials for shipboard and offshore units, power, control, instrumentation and telecommunication cables |
AS/NZS 60092.354:2020 | Electrical installations in ships Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) (IEC 60092-354:2014 (ED.3.0) MOD) |
IEC 62230:2006+AMD1:2013 CSV | Electric cables - Spark-test method |
IEC 60331-21:1999 | Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV |
ISO 7989-2:2007 | Steel wire and wire products Non-ferrous metallic coatings on steel wire Part 2: Zinc or zinc-alloy coating |
AS/NZS IEC 60092.353:2020 | Electrical installations in ships Power cables for rated voltages 1 kV and 3 kV |
IEC 60050-461:2008 | International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables |
IEC 60811-404:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths |
IEC 60331-1:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm |
IEC 60092-354:2014 | Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
IEC 60811-201:2012+AMD1:2017 CSV | Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness |
IEC 60332-3-22:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
IEC 61034-1:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus |
IEC 60811-403:2012 | Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds |
IEC 60885-2:1987 | Electrical test methods for electric cables. Part 2: Partial discharge tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.