IEC 60092-352:2005
Current
The latest, up-to-date edition.
Electrical installations in ships - Part 352: Choice and installation of electrical cables
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English, Spanish, Castilian
27-09-2005
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Types, construction, installation and operating conditions
of cables
3.1 Types of cables
3.2 Voltage rating
3.3 Cross-sectional areas of conductors and current
carrying capacities
3.4 Voltage drop
3.5 Estimation of lighting loads
3.6 Parallel connection of cables
3.7 Separation of circuits
3.8 Short circuit capacity (withstand capability)
3.9 Conductor
3.10 Insulation material
3.11 Screen, core screen or shield
3.12 Sheathing material
3.13 Metallic braid or armour
3.14 Fire performance
3.15 Cable runs
3.16 Cable installation methods in relation to
electromagnetic interference
3.17 Mechanical protection
3.18 Bending radius
3.19 Supports and fixing
3.20 Cables penetrating bulkheads and decks
3.21 Installation in metallic pipes or conduits or trunking
3.22 Installation in non-metallic pipes, conduits, trunking,
ducts or capping and casing
3.23 Installation in battery compartments
3.24 Installation in refrigeration spaces
3.25 Tensile stress
3.26 Special precautions for single core cables for a.c.
wiring
3.27 Cable ends
3.28 Joints and tappings (branch circuits)
3.29 Joint boxes
Annex A (informative) Tabulated current carrying capacities -
Defined installations
Annex B (informative) Tabulated current carrying capacities -
General installations
Annex C (informative) Fire stops
Annex D (informative) Cable splicing
Bibliography
This standard provides the basic requirements for the choice and installation of cables intended for fixed electrical systems on board ships at voltages (U) up to and including 15 kV. The reference to fixed systems includes those that are subjected to vibration (due to the movement of the ship) or movement (due to motion of the ship) and not to those that are intended for frequent flexing. Cables suitable for frequent or continual flexing use are detailed in other IEC specifications e.g. IEC 60227 and IEC 60245, and their uses on board ship is restricted to those situations which do not directly involve exposure to a marine environment e.g. portable tools or domestic appliances.
Committee |
TC 18/SC 18A
|
DevelopmentNote |
Supersedes IEC 60092-3. (03/2010) Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
ISBN |
2-8318-8231-1
|
Pages |
49
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN IEC 60092-352 : 2006 | Identical |
JIS F 8071:2008 | Identical |
UNE-IEC 60092-352:2015 | Identical |
IS 10242 : Part 3 : Sec 12 : 2023 | Identical |
SAC GB/T 13029.1 : 2003 | Identical |
UNE 21135-352:1998 | Identical |
CEI 18-50 : 2000 | Identical |
CEI 18-2 : 1ED 1982 | Identical |
BS 8450:2006 | Code of practice for installation of electrical and electronic equipment in ships |
UNE-EN ISO 16315:2016 | Small craft - Electric propulsion system (ISO 16315:2016) |
BS EN ISO 10133:2017 | Small craft. Electrical systems. Extra-low-voltage d.c. installations |
12/30227396 DC : 0 | BS EN ISO/DIS 16315 - SMALL CRAFT - ELECTRIC PROPULSION SYSTEM |
CEI EN 60092-507 : 2016 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS |
BS EN 60092-507:2015 | Electrical installations in ships Small vessels |
09/30196635 DC : 0 | BS EN 60092-510 - ELECTRICAL INSTALLATIONS IN SHIPS - SPECIAL FEATURES - HIGH VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS) |
I.S. EN ISO 16315:2016 | SMALL CRAFT - ELECTRIC PROPULSION SYSTEM (ISO 16315:2016) |
CEI 18-52 : 2013 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 354: SINGLE- AND THREE-CORE POWER CABLES WITH EXTRUDED SOLID INSULATION FOR RATED VOLTAGES 6 KV (U[M] = 7,2 KV) UP TO 30 KV (U[M] = 36 KV) |
ISO 13617:2001 | Ships and marine technology Shipboard incinerators Requirements |
IEC TR 62482:2008 | Electrical installations in ships - Electromagnetic compatibility - Optimising of cable installations on ships - Testing method of routing distance |
IEC PAS 60092-510:2009 | Electrical installations in ships - Part 510: Special features - High-voltage shore connection systems |
IEC 60092-504:2016 RLV | Electrical installations in ships - Part 504: Automation, control and instrumentation |
CEI 18-64 : 2008 | MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES |
ISO 10133:2012 | Small craft Electrical systems Extra-low-voltage d.c. installations |
BS IEC 60092-306:2009 | Electrical installations in ships Equipment. Luminaires and lighting accessories |
13/30278886 DC : 0 | BS EN 60092-501 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 501: SPECIAL FEATURES - ELECTRIC PROPULSION PLANT |
BS IEC 60533:2015 | Electrical and electronic installations in ships. Electromagnetic compatibility (EMC). Ships with a metallic hull |
UNE-IEC 60092-306:2010 | Electrical installations in ships - Part 306: Equipment - Luminaires and lighting accessories |
BS IEC 60092-101:1994 | Electrical installation in ships Definitions and general requirements |
UNE-IEC 60092-101:2010 | Electrical installations in ships - Part 101: Definitions and general requirements |
IEC 61892-4:2007 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
IEC 60092-201:1994 | Electrical installations in ships - Part 201: System design - General |
IEC 60533:2015 | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
IEC 60092-376:2017 RLV | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
BS 6883:1999 | Elastomer insulated cables for fixed wiring in ships and on mobile and fixed offshore units. Requirements and test methods |
VDE 0129-507 : 2001 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: PLEASURE CRAFT (IEC 60092-507:2000) |
ISO 10134:2003 | Small craft Electrical devices Lightning-protection systems |
18/30371445 DC : 0 | BS ISO 13617 - SHIPS AND MARINE TECHNOLOGY - SHIPBOARD INCINERATORS - REQUIREMENTS |
DIN EN ISO 16315:2016-08 | SMALL CRAFT - ELECTRIC PROPULSION SYSTEM (ISO 16315:2016) |
07/30167170 DC : 0 | BS EN ISO 10133 - SMALL CRAFT - ELECTRICAL SYSTEMS - EXTRA-LOW-VOLTAGE D.C. INSTALLATIONS |
IEC 60092-501:2013 | Electrical installations in ships - Part 501: Special features - Electric propulsion plant |
BS IEC 60092-501:2013 | Electrical installations in ships Special features. Electric propulsion plant |
I.S. EN 60092-507:2015 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS |
IEC 60092-504:2016 | Electrical installations in ships - Part 504: Automation, control and instrumentation |
IEC 60092-507:2014 | Electrical installations in ships - Part 507: Small vessels |
I.S. EN ISO 10133:2017 | SMALL CRAFT - ELECTRICAL SYSTEMS - EXTRA-LOW-VOLTAGE D.C. INSTALLATIONS (ISO 10133:2012) |
BS IEC 60092-504:2016 | Electrical installations in ships Automation, control and instrumentation |
08/30186163 DC : DRAFT JULY 2008 | BS IEC 60092-306 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 306: EQUIPMENT - LUMINAIRES AND LIGHTING ACCESSORIES |
CEI 18-67 : 2013 | ELECTRICAL INSTALLATIONS IN SHIPS - ELECTROMAGNETIC COMPATIBILITY - OPTIMISING OF CABLE INSTALLATIONS ON SHIPS - TESTING METHOD OF ROUTING DISTANCE |
01/202703 DC : DRAFT APRIL 2001 | IEC 60092-354 ED.2 - ELECTRICAL INSULATION IN SHIPS - PART 354: SINGLE AND THREE CORE POWER CABLES WITH EXTRUDED SOLID INSULATION FOR RATED VOLTAGES 6 KV (UM EQUALS 7.2 KV) UP TO 30 KV (UM EQUALS 36 KV) |
BS ISO 13617:2001 | Ships and marine technology. Shipboard incinerators. Requirements |
IEC TR 60092-370:2009 | Electrical installations in ships - Part 370: Guidance on the selection of cables for telecommunication and data transfer including radio-frequency cables |
UNE-IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC PAS 63108:2017 | Electrical installation in ships - Primary DC distribution - System design architecture |
ISO 16315:2016 | Small craft Electric propulsion system |
EN 60092-507:2015/AC:2015 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS |
UNE-IEC 61892-4:2016 | Mobile and fixed offshore units - Electrical installations - Part 4: Cables |
EN ISO 16315:2016 | Small craft - Electric propulsion system (ISO 16315:2016, Corrected version 2021-11) |
13/30292538 DC : 0 | BS EN 60092-507 ED 3.0 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: SMALL VESSELS |
EN ISO 10133:2017 | Small craft - Electrical systems - Extra-low-voltage d.c. installations (ISO 10133:2012) |
15/30302640 DC : 0 | BS IEC 60092-504 ED 4.0 - ELECTRICAL INSTALLATIONS IN SHIPS - PART 504: AUTOMATION, CONTROL AND INSTRUMENTATION |
DIN EN ISO 10133:2013-04 | Small craft - Electrical systems - Extra-low-voltage d.c. installations (ISO 10133:2012) |
IEC 60092-101:1994+AMD1:1995 CSV | Electrical installations in ships - Part 101: Definitions and general requirements |
IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 60092-306:2009 | Electrical installations in ships - Part 306: Equipment - Luminaires and lighting accessories |
IEC 60533:2015 RLV | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60986:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEC 60684-2:2011 | Flexible insulating sleeving - Part 2: Methods of test |
IEC 60331-31:2002 | Tests for electric cables under fire conditions - Circuit integrity - Part 31: Procedures and requirements for fire with shock - Cables of rated voltage up to and including 0,6/1 kV |
IEC 60702-1:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables |
IEC 60724:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
AS/NZS IEC 60092.376:2020 | Electrical installations in ships Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
IEC 60332-1-3:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for determination of flamingdroplets/particles |
IEC 60754-1:2011 | Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content |
IEC 60092-375:1977 | Electrical installations in ships. Shipboard telecommunication cables and radio-frequency cables. General instrumentation, control and communication cables |
IEC 61363-1:1998 | Electrical installations of ships and mobile and fixed offshore units - Part 1: Procedures for calculating short-circuit currents in three-phase a.c. |
IEC 60332-1-1:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 60092-376:2017 | Electrical installations in ships - Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) |
IEC 60092-201:1994 | Electrical installations in ships - Part 201: System design - General |
IEC 60092-351:2004 | Electrical installations in ships - Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables |
IEC 60092-374:1977 | Electrical installations in ships. Shipboard telecommunication cables and radio-frequency cables. Telephone cables for non-essential communication services |
IEC 60092-353:2016 | Electrical installations in ships - Part 353: Power cables for rated voltages 1 kV and 3 kV |
IEC 60092-203:1985 | Electrical installations in ships. Part 203: System design - Acoustic and optical signals |
IEC 60754-2:2011 | Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity |
IEC 60331-21:1999 | Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV |
IEC 60533:2015 | Electrical and electronic installations in ships - Electromagnetic compatibility (EMC) - Ships with a metallic hull |
IEC 60092-359:1987+AMD1:1994+AMD2:1999 CSV | Electrical installations in ships - Part 359: Sheathing materials for shipboard power and telecommunication cables |
IEC 60092-354:2014 | Electrical installations in ships - Part 354: Single- and three-core power cables with extruded solid insulation for rated voltages 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
IEC 60092-101:1994+AMD1:1995 CSV | Electrical installations in ships - Part 101: Definitions and general requirements |
IEC 60092-401:1980 | Electrical installations in ships - Part 401: Installation and test of completed installation |
IEC 60332-3-22:2000+AMD1:2008 CSV | Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A |
IEC 61034-2:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements |
IEC 60092-350:2014 | Electrical installations in ships - Part 350: General construction and test methods of power, control and instrumentation cables for shipboard and offshore applications |
IEC 60702-2:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltagenot exceeding 750 V - Part 2: Terminations |
IEC 60092-373:1977 | Electrical installations in ships. Shipboard telecommunication cables and radio-frequency cables. Shipboard flexible coaxial cables |
IEC 60364-5-52:2009 | Low-voltage electrical installations - Part 5-52: Selection and erection of electrical equipment - Wiring systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.