IEC 60099-9:2014
Current
The latest, up-to-date edition.
Surge arresters - Part 9: Metal-oxide surge arresters without gaps for HVDC converter stations
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
26-06-2014
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Typical HVDC converter station schemes,
arrester types, locations and operating
voltage
5 Identification and classification
6 Service conditions
7 Requirements
8 General testing procedure
9 Type tests (design tests)
10 Routine tests and acceptance test
11 Test requirements on different types
of arresters
Annex A (normative) - Test to verify thermal
equivalency between complete arrester
and arrester section
Annex B (normative) - Determination of the start
temperature in the thermal recovery test
Annex C (normative) - Mechanical considerations
Annex D (informative) - Different circuit configurations
Bibliography
IEC 60099-9:2014 applies to non-linear metal-oxide resistor type surge arresters without spark gaps designed to limit overvoltages in HVDC converter stations of two terminal, multiterminal and back-to-back type up to and including an operating voltage of 1 100 kV. The standard applies in general to porcelain-housed and polymer-housed type arresters but also to gas-insulated metal enclosed arresters (GIS-arresters) solely used as d.c. bus and d.c. line/cable arresters. Arresters for voltage source converters are not covered. Arresters applied on the a.c. systems at the converter station and subjected to power-frequency voltage of 50 or 60 Hz principally without harmonics are tested as per IEC 60099-4. The arresters on a.c.-filters are tested according to this standard. Keywords: testing of gapless metal-oxide surge arrestors for HVDC converter stations
Committee |
TC 37
|
DevelopmentNote |
Stability date: 2019. (07/2014)
|
DocumentType |
Standard
|
Pages |
185
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NF EN 60099-9 : 2015 | Identical |
NBN EN 60099-9 : 2014 | Identical |
NEN EN IEC 60099-9 : 2014 | Identical |
PN EN 60099-9 : 2015 | Identical |
DIN EN 60099-9 : 2015 | Identical |
VDE 0675-9 : 2015 | Identical |
BS EN 60099-9:2014 | Identical |
CEI EN 60099-9 : 2015 | Identical |
EN 60099-9:2014 | Identical |
SN EN 60099-9:2014 | Identical |
UNE-EN 60099-9:2014 | Identical |
PNE-FprEN 60099-9 | Identical |
IEC TS 63014-1:2018 | High voltage direct current (HVDC) power transmission - System requirements for DC-side equipment - Part 1: Using line-commutated converters |
IEC/IEEE 60076-57-129:2017 | Power transformers - Part 57-129: Transformers for HVDC applications |
IEC 62848-1:2016 | Railway applications - DC surge arresters and voltage limiting devices - Part 1: Metal-oxide surge arresters without gaps |
IEC TR 62001-4:2016 | High-voltage direct current (HVDC) systems - Guidance to the specification and design evaluation of AC filters - Part 4: Equipment |
IEEE C62.33-1982 | IEEE Standard Test Specifications for Varistor Surge-Protective Devices |
PD IEC/TR 62001-4:2016 | High-voltage direct current (HVDC) systems. Guidance to the specification and design evaluation of AC filters Equipment |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
ISO 4892-1:2016 | Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance |
IEC 60143-2:2012 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60143-1:2015 | Series capacitors for power systems - Part 1: General |
IEC 62271-200:2011 | High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV |
IEC 60099-4:2014 | Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
IEC 62217:2012 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
IEC TS 60815-2:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 2: Ceramic and glass insulators for a.c. systems |
IEC 60068-2-11:1981 | Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist |
IEC TS 60071-5:2002 | Insulation co-ordination - Part 5: Procedures for high-voltage direct current (HVDC) converter stations |
ISO 4892-3:2016 | Plastics — Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
IEC 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
CISPR TR 18-2:2017 | Radio interference characteristics of overhead power lines and high-voltage equipment - Part 2: Methods of measurement and procedure for determining limits |
IEC 60633:1998+AMD1:2009+AMD2:2015 CSV | Terminology for high-voltage direct current (HVDC) transmission |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
ISO 4892-2:2013 | Plastics — Methods of exposure to laboratory light sources — Part 2: Xenon-arc lamps |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
IEC TS 60815-3:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 3: Polymer insulators for a.c. systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.
Logging out.