IEC 60115-2:2014
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Fixed resistors for use in electronic equipment - Part 2: Sectional specification: Leaded fixed low power film resistors
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
15-02-2023
English - French
14-05-2014
IEC 60115-2:2014 is applicable to leaded fixed low-power film resistors for use in electronic equipment. These resistors are typically described according to types (different geometric shapes) and styles (different dimensions) and product technology. The resistive element of these resistors is typically protected by a conformal lacquer coating. These resistors have wire terminations and are primarily intended to be mounted on a circuit board in through-hole technique. The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60115-1, the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of resistor. This edition includes the following significant technical changes with respect to the previous edition:
- it includes test conditions and requirements for lead-free soldering and assessment procedures meeting the requirements of a "zero defect" approach;
- it introduces a product classification based on application requirements;
- it includes an extension of the list of styles and dimensions;
- it includes the use of an extended scope of stability class definitions;
- it includes the extension of the lists of preferred values of ratings;
- it includes test conditions and requirements for lead-free soldering, for periodic overload and for resistance to electrostatic discharge (ESD);
- it includes a new set of severities for a shear test;
- it includes definitions for a test board;
- it includes the replacement of assessment level E and possible others by the sole assessment level EZ, meeting the requirements of a "zero defect" approach;
- it includes an extended endurance test, a flammability test, a temperature rise test, vibration tests, an extended rapid change of temperature test, and a single pulse high-voltage overload test;
- it includes requirements applicable to 0-ohm resistors (jumpers);
- it includes recommendations for the denomination, description, packaging and quality assessment of radial formed styles;
- it includes prescriptions for endurance testing at room temperature, supplementary to the rulings of IEC 60115-1.
Committee |
TC 40
|
DevelopmentNote |
Stability date: 2023. (05/2014)
|
DocumentType |
Standard
|
Pages |
139
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
SN EN 60115-2:2015 | Identical |
UNE-EN 60115-2:2015 | Identical |
NEN 10115-2 : 1983 | Identical |
UNE 20545-2:1985 | Identical |
DIN IEC 60115-2:1987-04 | Identical |
NBN C 83 200 : 1984 | Identical |
13/30283837 DC : 0 | BS EN 62812 - METHOD OF MEASUREMENT OF LOW RESISTANCE |
BS CECC 40000:1980 | Harmonized system of quality assessment for electronic components. Generic specification: fixed resistors |
IEC 61193-2:2007 | Quality assessment systems - Part 2: Selection and use of sampling plans for inspection of electronic components and packages |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IECQ 03-3:2013 | IEC QUALITY ASSESSMENT SYSTEM FOR ELECTRONIC COMPONENTS (IECQ SYSTEM) - RULES OF PROCEDURE - PART 3: IECQ APPROVED COMPONENT PRODUCTS, RELATED MATERIALS & ASSEMBLIES SCHEME |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
IEC 61192-3:2002 | Workmanship requirements for soldered electronic assemblies - Part 3: Through-hole mount assemblies |
IEC 60286-2:2015 | Packaging of components for automatic handling - Part 2: Tape packaging of components with unidirectional leads on continuous tapes |
IEC 61760-1:2006 | Surface mounting technology - Part 1: Standard method for the specification of surface mounting components (SMDs) |
IEC 60027-1:1992 | Letters symbols to be used in electrical technology - Part 1: General |
IEC 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
IECQ 03-3-1:2013 | IEC QUALITY ASSESSMENT SYSTEM FOR ELECTRONIC COMPONENTS (IECQ SYSTEM) - RULES OF PROCEDURE - PART 3-1: IECQ APPROVED COMPONENT PRODUCTS, RELATED MATERIALS & ASSEMBLIES SCHEME, IECQ APPROVED COMPONENT-TECHNOLOGY CERTIFICATION (IECQ AC-TC) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60062:2016 | Marking codes for resistors and capacitors |
IEC 61340-3-1:2006 | Electrostatics - Part 3-1: Methods for simulation of electrostatic effects - Human body model (HBM) electrostatic discharge test waveforms |
IEC 60301:2012 | Preferred diameters of wire terminations of capacitors and resistors |
IEC 60063:2015 | Preferred number series for resistors and capacitors |
IEC 60717:2012 | Method for the determination of the space required by capacitors and resistors with unidirectional terminations |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60286-1:2017 | Packaging of components for automatic handling - Part 1: Tape packaging of components with axial leads on continuous tapes |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60440:2012 | Method of measurement of non-linearity in resistors |
IEC 60115-1:2008 | Fixed resistors for use in electronic equipment - Part 1: Generic specification |
IEC 60195:2016 | Method of measurement of current noise generated in fixed resistors |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.