IEC 60183:2015
Current
The latest, up-to-date edition.
Guidance for the selection of high-voltage A.C. cable systems
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
14-01-2015
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Cable insulation levels
6 Selection of the conductor size
7 Accessories
8 Environmental aspects
Annex A (informative) - System monitoring
Bibliography
IEC 60183:2015 gives guidance in the selection of a.c. high-voltage cables and cable systems with extruded insulation and mainly to be used on three-phase alternating systems operating at voltages exceeding U = 1 kV (in this standard the term high voltage is used to cover any cable above 1 kV). Submarine cables are not included in the scope. Guidance is given in the selection of the conductor size, insulation level and constructional requirements of cable to be used. In addition, information necessary to enable the appropriate selection to be made is summarized. Paper insulated power cables are not considered in this standard for their selection into cable systems. However, when selecting cables with extruded insulation to be connected together with existing paper insulated cables, particular consideration for their proper compatibility, accessories and operational characteristics should be made. Environmental aspects are mentioned at the level at which they may influence the selection of high-voltage cables and their application. This third edition cancels and replaces the second edition, published in 1984, and its Amendment 1 (1990) and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- the scope has been changed to a.c. high-voltage cables and cable systems;
- guidance relates to cables with extruded insulation;
- submarine cables are not covered but cables laid in water are covered;
- operation of systems with special bonding of the screen is covered;
- there is guidance on accessories;
- environmental aspects are addressed.
Committee |
TC 20
|
DevelopmentNote |
Stability Date: 2023. (01/2015)
|
DocumentType |
Standard
|
Pages |
29
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
VDE 0276-183 : 2016 | Identical |
DIN IEC 60183 : 2016 | Identical |
BS IEC 60183:2015 | Identical |
UNE-EN 50556:2011 | Road traffic signal systems |
BS 4553-1:1998 | Specification for 600/1000 V single-phase split concentric electric cables Cables having PVC insulation |
BS 7923:2004 | Electric cables. Internal gas-pressure cables and accessories for alternating voltages up to and including 275 kV (<i>U</i><sub>m</sub> = 300 kV). Requirements and test methods |
BS 7889:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000 V, for fixed installations |
07/30143023 DC : DRAFT MAR 2007 | BS 7835 - ELECTRIC CABLES - ARMOURED CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
BS 7870-6.3:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - Cables with thermosetting insulation and non-halogenated sheath |
11/30214055 DC : 0 | BS 7870-1 - LV AND MV POLYMERIC INSULATED CABLES FOR USE BY DISTRIBUTION AND GENERATION UTILITIES - PART 1: GENERAL |
HD 633 S1:1997 | Tests on oil-filled (fluid filled), paper- or polypropylene paper laminate-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (Um = 420 kV) |
BS EN 45510-2-8:2004 | Guide for procurement of power station equipment Electrical equipment - Power cables |
CEI 20-71 : 2003 | TESTS ON OIL-FILLED (FLUID FILLED), PAPER- AND PPL-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (UM = 420 KV) |
BS 4553-3:1998 | Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire |
17/30347740 DC : 0 | BS EN 63075 - SUPERCONDUCTING AC POWER CABLES AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 6 KV TO 500 KV - TEST METHODS AND REQUIREMENTS |
BS 7870-1:2011 | LV and MV polymeric insulated cables for use by distribution and generation utilities General |
CEI UNI EN 45510-2-8 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
I.S. HD 632:2016 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
I.S. HD 603:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
HD 635 : 200S1 | TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (UM = 300 KV) |
I.S. HD 634:1999 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (UM = 300 KV) |
UNE 211067-1:2017 | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 400 kV (Um = 420 kV). Part 1: Test methods and requirements. |
IEC 60055-1:1997+AMD1:2005 CSV | Paper-insulated metal-sheathed cables for rated voltages up to 18/30 kV (with copper or aluminium conductors and excluding gas-pressure and oil-filled cables) - Part 1: Tests on cables and their accessories |
IEC 62067:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements |
BS 7846:2015 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1 000 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7846:2000 | Electric cables. 600/1000 V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire |
HD 620 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
HD 603 S1:1994/A3:2007 | DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV |
EN 45510-2-8 : 2004 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
BS 7846:2009 | Electric cables. Thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000 V, having low emission of smoke and corrosive gases when affected by fire. Specification |
BS 7769-3.1:1997 | Electric cables. Calculation of the current rating. Sections on operating conditions Reference operating conditions and selection of cable type |
BS IEC 62895:2017 | High voltage direct current (HVDC) power transmission. Cables with extruded insulation and their accessories for rated voltages up to 320 kV for land applications. Test methods and requirements |
14/30290103 DC : 0 | BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS |
UNE 211067-2:2017 | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 400 kV (Um = 420 kV). Part 2: Cables with XLPE insulation and polyolefin compound sheath or high density polyethylene (HDPE) compound sheath. |
15/30301501 DC : 0 | BS 5467 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, FOR FIXED INSTALLATIONS - SPECIFICATION |
13/30291844 DC : 0 | BS EN 60230 - IMPULSE TESTS ON CABLES AND THEIR ACCESSORIES |
12/30244462 DC : 0 | BS 8573 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS, HAVING LOW EMISSIONS OF SMOKE AND CORROSIVE WHEN AFFECTED BY FIRE |
BS 7870-8.5:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath - Section 8.5 Single wire armoured and unarmoured multicore cables with copper conductors and non-halogenated sheath |
06/30143016 DC : DRAFT SEP 2006 | BS 6622 - SPECIFICATION FOR CABLES WITH THERMOSETTING INSULATION FOR RATED VOLTAGES FROM 3.8/6.6 KV TO 19/33 KV |
98/232755 DC : DRAFT DEC 1998 | IEC 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
CEI 20-21/3-1 : 2007 | ELECTRIC CABLES - CALCULATION OF THE CURRENT RATING - PART 3-1: SECTIONS ON OPERATING CONDITIONS - REFERENCE OPERATING CONDITIONS AND SELECTION OF CABLE TYPE |
UNE 211632-4A:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 4A: Cables with XLPE insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath. |
UNE-HD 603-5X:2007 | Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section X: Polyolefin sheathed cables without concentric conductor (Type 5X-1) |
HD 627 S1:1996/A2:2005 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
VDE 0276-621 : 1997 | POWER CABLES - PART 621: MEDIUM VOLTAGE IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES |
IEC 60840:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements |
IEC 60502-4:2010 | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (U<sub>m</sub> = 1,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) - Part 4: Test requirements on accessories for cables with rated voltages from 6 kV (U<sub>m</sub> = 7,2 kV) up to 30 kV (U<sub>m</sub> = 36 kV) |
I.S. HD 627:2003 | MULTICORE AND MULTIPAIR CABLES FOR INSTALLATION ABOVE AND BELOW GROUND |
BS 6622:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV. Requirements and test methods |
VDE 0276-634 : 1999 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
DIN VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
BS 4553:1992 | Specification for 600/1000 V PVC-insulated single-phase split concentric cables with copper conductors for electricity supply |
BS 6724(1997) : 1997 | ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE |
BS 6622:1999 | Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3.8/6.6 kV up to 19/33 kV |
BS 7889:1997 | Electric cables. Thermosetting insulated, unarmoured cables for a voltage of 600/1000 V |
VDE 0276-635 : 1999 | TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
BS 5467(1997) : 1997 | ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1900/3300 V |
BS 6622:1991 | Specification for cables with extruded cross-linked polyethylene or ethylene propylene rubber insulation for rated voltages from 3800/6600 V up to 19000/33000 V |
BS 7912(2012) : 2012 | POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
DIN VDE 0276-634 : 1999 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
BS 7835:2007 | Electric cables. Armoured cables with thermosetting insulation for rated voltages from 3.8/6.6 kV to 19/33 kV having low emission of smoke and corrosive gases when affected by fire. Requirements and test methods |
DIN VDE 0276-635 : 1999 | TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (U[M] = 300 KV) |
VDE 0276-633 : 1999 | TESTS ON OIL-FILLED (FLUID-FILLED), PAPER- AND POLYPROPYLENE PAPER LAMINATE-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (U[M] = 420 KV) |
BS 6724:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations, having low emission of smoke and corrosive gases when affected by fire. Specification |
10/30217405 DC : 0 | BS EN 50556 - ROAD TRAFFIC SIGNAL SYSTEMS |
12/30244367 DC : 0 | BS 7912 - POWER CABLES WITH XLPE INSULATION AND METAL SHEATH, AND THEIR ACCESSORIES, FOR RATED VOLTAGES FROM 66 KV (U[M] = 72.5 KV) TO 132 KV (U[M] = 145 KV) |
BS 4553-2:1998 | Specification for 600/1000 V single-phase split concentric electric cables Cables having thermosetting insulation |
15/30301742 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - REQUIREMENTS AND TEST METHODS |
UNE-HD 603-5N:2007 | Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section N: PVC sheathed cables without concentric conductor. (Type 5N) |
ESPECIFICACION UNE 0051:2017 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1 and type 3). |
I.S. EN IEC 60230:2018 | IMPULSE TESTS ON CABLES AND THEIR ACCESSORIES |
BS 5467:2016 | Electric cables. Thermosetting insulated, armoured cables of rated voltages of 600/1 000 V and 1 900/3 300 V for fixed installations. Specification |
EA 0051:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTE insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
ESPECIFICACION UNE 0052:2017 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
EN IEC 60230:2018 | Impulse tests on cables and their accessories |
NF EN 50556 : 2011 | ROAD TRAFFIC SIGNAL SYSTEMS |
DIN VDE 0276-621 : 1997 | POWER CABLES - PART 621: MEDIUM VOLTAGE IMPREGNATED PAPER INSULATED DISTRIBUTION CABLES |
UNE-HD 620-10E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 10: XLPE insulated single core and 3 core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 10E-1, 10E-3, 10E-4 and 10E-5). |
UNE-HD 620-9E:2012 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 9: HEPR insulated single core cables, and single core pre-assembled cables. Section E: Cables with polyolefine compound sheath (types 9E-1, 9E-3, 9E-4 and 9E-5). |
BS 6346:1997 | Electric cables. PVC insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V |
EN 45510-2-8:2004 | Guide for procurement of power station equipment - Part 2-8: Electrical equipment - Power cables |
BS EN IEC 60230:2018 | Impulse tests on cables and their accessories |
BS 7870-6.2:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations - XLPE or HEPR insulated and PVC sheathed cables |
NFC 33 051 : 96 AMD 1 1998 XP | INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SCREENED SEPARABLE CONNECTORS AND ASSOCIATED DEVICES FOR RATED VOLTAGES FROM 6/10 (12) KV UP TO 18/30 (36) KV |
EA 0052:2014 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV to 20,8/36 (42) kV. HPTR insulated single core cables and single core pre-assembled cables. Cables with polyolefine compound sheath (type 1, type 2 and type 3). |
BS 7922:2004 | Electric cables. Fluid-filled, paper- and PPL-insulated, metal-sheathed cables and accessories for alternating voltages up to and including 400 kV (<i>U</i><sub>m</sub> = 420 kV). Requirements and test methods |
BS 7769-1.1:1997 | Electric cables. Calculation of the current rating. Current rating equations (100% load factor) and calculation of losses General |
09/30199575 DC : 0 | BS 7846 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED, FIRE-RESISTANT CABLES OF RATED VOLTAGE 600/1000 V HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
UNE 211632-1:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 1: Requirements and test methods |
BS 7870-6.1:1999 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for 0.6/1 kV and 1.9/3.3 kV power cables with special fire performance for use in power stations PVC insulated and PVC sheathed cables |
15/30301443 DC : 0 | BS 6724 - ELECTRIC CABLES - THERMOSETTING INSULATED, ARMOURED CABLES FOR VOLTAGES OF 600/1000 V AND 1 900/3300 V FOR FIXED INSTALLATIONS, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
CEI 20-66 : 2010 | POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV) |
EN 50556:2011 | Road traffic signal systems |
CEI EN 50556 : 2012 | ROAD TRAFFIC SIGNAL SYSTEMS |
I.S. HD 620:2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV |
IEC 60502-2:2014 RLV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) |
IEC 60141-1:1993 | Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV |
BS 7870-8.2:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multipair cable with copper conductors - Section 8.2 Single wire armoured and PVC sheathed multipair cable with copper conductors |
BS EN 50556:2011 | Road traffic signal systems |
I.S. EN 45510-2-8:2004 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
HD 634 : 200S1 | TESTS ON INTERNAL GAS-PRESSURE CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (UM = 300 KV) |
BS 8573:2012 | Electric cables. Thermosetting insulated, non-armoured cables with a voltage of 600/1 000V, for fixed installations, having low emissions of smoke and corrosive gases when affected by fire |
UNE 211632-6A:2017 | Power cables with extruded insulation and their accessories for rated voltages above 36 kV (Um = 42 kV) up to 150 kV (Um = 170 kV). Part 6A: Cables with HEPR insulation and polyolefin compound sheath (Types 1, 2 and 3) or high density polyethylene (HDPE) compound sheath. |
12/30244369 DC : 0 | BS 7889 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED CABLES WITH A VOLTAGE OF 600/1000 V, FOR FIXED INSTALLATIONS |
I.S. EN 50556:2011 | ROAD TRAFFIC SIGNAL SYSTEMS |
IEC 60502:1994 | Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV |
BS 7870-8.3:2003 | LV and MV polymeric insulated cables for use by distribution and generation utilities. Specification for multicore and multipair cables for installation above and below ground Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance - Section 8.3 Single wire armoured and PVC sheathed multicore cable with copper conductors, having reduced fire propagation performance |
03/318201 DC : DRAFT NOV 2003 | IEC 60502-2, ED.2 - POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 KV (UM = 1,2 KV) UP TO 30 KV (UM = 36 KV) - PART 2: CABLES FOR RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 30 KV (UM = 36 KV) |
PREN 50556 : DRAFT 2010 | ROAD TRAFFIC SIGNAL SYSTEMS |
IEC 60230:2018 | Impulse tests on cables and their accessories |
UNI CEI EN 45510-2-8 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-8: ELECTRICAL EQUIPMENT - POWER CABLES |
I.S. HD 635:1999 | TESTS ON EXTERNAL GAS-PRESSURE (GAS COMPRESSION) CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 275 KV (UM = 300 KV) |
CEI 20-56 : 2010 | DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV SOMMARIO |
IEC 60502-1:2004+AMD1:2009 CSV | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
I.S. HD 633:1999 | TESTS ON OIL-FILLED (FLUID FILLED), PAPER- OR POLYPROPYLENE PAPER LAMINATED-INSULATED, METAL-SHEATHED CABLES AND ACCESSORIES FOR ALTERNATING VOLTAGES UP TO AND INCLUDING 400 KV (UM = 420 KV) |
UNE-HD 620-1:2010 | Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV. Part 1: General requirements. |
SAE AIR7374 | Aging Mechanisms of Electrical Insulation Materials in a High Energy System |
IEC TR 62602:2009 | Conductors of insulated cables - Data for AWG and KCMIL sizes |
IEC 60228:2004 | Conductors of insulated cables |
IEC 60502:1994 | Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30 kV |
IEC 62067:2011 RLV | Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements |
IEC 62271-209:2007 | High-voltage switchgear and controlgear - Part 209: Cable connections for gas-insulated metal-enclosed switchgear for rated voltages above 52 kV - Fluid-filled and extruded insulation cables - Fluid-filled and dry-type cable-terminations |
IEC 60287-3-2:2012 | Electric cables - Calculation of the current rating - Part 3-2: Sections on operating conditions - Economic optimization of power cable size |
IEC 60287-3-1:2017 | Electric cables - Calculation of the current rating - Part 3-1: Operating conditions - Site reference conditions |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC TS 60815-1:2008 | Selection and dimensioning of high-voltage insulators intended for use in polluted conditions - Part 1: Definitions, information and general principles |
IEC 60287-1-1:2006+AMD1:2014 CSV | Electric cables - Calculation of the current rating - Part 1-1:Current rating equations (100 % load factor) and calculation of losses - General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.