IEC 60352-3:1993
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
08-02-1993
Foreword
Introduction
Section 1: General
1. Scope
2. Object
3. Normative references
4. Definitions
5. IEC type designation
Section 2: Requirements
6. Workmanship
7. Tools
8. Insulation displacement terminations (ID terminations)
9. Wires
10. Accessible insulation displacement connections (ID
connections)
Section 3: Tests
11. Testing
12. Type tests
13. Test schedules
Section 4: Practical guidance
14. Current-carrying capacity
15. Tool information
16. Termination information
17. Wire information
18. Connection information
Annex ZA (normative) Other international publications
quoted in this standard with the references of the
relevant European publications
Applies to ID connections which are accessible for tests and measurements, and which are made with: -appropriately designed ID terminations -wires having solid round conductors of 0,25 mm to 3,6 mm nominal diameter -wires having stranded conductors of 0,05 mm2 to 10 mm2 cross-section. The contents of the corrigendum of November 1995 have been included in this copy.
DevelopmentNote |
Also numbered as BS EN 60352-3. (10/2005) Stability Date: 2018. (10/2012)
|
DocumentType |
Standard
|
Pages |
62
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
UNE-EN 60352-3:1998 | Identical |
DIN EN 60352-3:1995-05 | Identical |
PN EN 60352-3 : DEC 2002 | Identical |
SN EN 60352-3 : 1994 | Identical |
SAC GB/T 18290.3 : 2000 | Identical |
I.S. EN 60352-3:1995 | Identical |
EN 60352-3:1994 | Identical |
CEI EN 60352-3 : 1996 | Identical |
NF EN 60352-3 : 2002 | Identical |
NEN 10352-3 : 1995 | Identical |
ONORM OVE EN 60352-3 : 1995 | Identical |
I.S. EN 62790:2015 | JUNCTION BOXES FOR PHOTOVOLTAIC MODULES - SAFETY REQUIREMENTS AND TESTS |
12/30270756 DC : 0 | BS EN 61076-3-104 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-104: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED FREE AND FIXED CONNECTORS FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 2000 MHZ |
BS ISO/IEC 11801-1:2017 | Information technology. Generic cabling for customer premises General requirements |
09/30208429 DC : 0 | BS EN 50467 - RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS |
PD IEC TR 62225:2001 | Guidance on terms for connectors and mechanical structures in electronic equipment |
BS IEC 62790 : 2014 | JUNCTION BOXES FOR PHOTOVOLTAIC MODULES - SAFETY REQUIREMENTS AND TESTS |
02/206147 DC : DRAFT AUG 2002 | IEC 60603-7-4 ED.1.0 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-4: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ (CAT 6, UNSHIELDED) |
CSA T568.2-4 : 2005 : R2010 | COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 2: BALANCED TWISTED PAIR CABLING COMPONENTS - ADDENDUM 4 - SOLDERLESS CONNECTION RELIABILITY REQUIREMENTS FOR COPPER CONNECTING HARDWARE |
CSA T568.2-4 :2005 | COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD - PART 2: BALANCED TWISTED PAIR CABLING COMPONENTS - ADDENDUM 4 - SOLDERLESS CONNECTION RELIABILITY REQUIREMENTS FOR COPPER CONNECTING HARDWARE |
02/202649 DC : DRAFT JAN 2002 | IEC PAS 61076-3-111. ED.1 - CONNECTORS FOR USE IN ELECTRONIC EQUIPMENT - PART 3-111: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED AND UNSHIELDED, FREE AND FIXED CONNECTORS, FOR INDUSTRIAL ENVIRONMENTS FOR FREQUENCIES UP TO 250 MHZ |
UNE-EN 50467:2012 | Railway applications - Rolling stock - Electrical connectors, requirements and test methods |
CSA ISO/IEC 15018 : 2005 : R2010 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018:2005 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R201000 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
NF EN 62852 : 2015 | CONNECTORS FOR DC-APPLICATION IN PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
I.S. EN 50467:2011 | RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS |
BS EN 50548 : 2011 | JUNCTION BOXES FOR PHOTOVOLTAIC MODULES |
BS IEC 62852 : 2014 | CONNECTORS FOR DC-APPLICATION IN PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
EN 61076-4-108:2002 | Connectors for electronic equipment - Part 4-108: Printed board connectors with assessed quality - Detail specification for cable-to-board connectors, with a modular pitch of 25 mm and integrated shielding function, applicable for transverse packing density of 15 mm, having a basic grid of 2,5 mm in accordance with IEC 60917-1 |
BS EN 61076-4:1997 | Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high speed data applications Sectional specification. Printed board connectors |
I.S. EN 61076-4:1998 | CONNECTORS WITH ASSESSED QUALITY, FOR USE IN D.C., LOW FREQUENCY ANALOGUE AND IN DIGITAL HIGH-SPEED DATA APPLICATIONS - PART 4: SECTIONAL SPECIFICATION - PRINTED BOARD CONNECTORS |
NF EN 50521 : 2009 AMD 1 2012 | CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
06/30152213 DC : DRAFT JUNE 2006 | BS EN 60603-7-1 ED. 2 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-1: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS |
03/100166 DC : DRAFT JAN 2003 | IEC 60603-7-5 ED.1.0 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-5: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
03/100167 DC : DRAFT JAN 2003 | IEC 60603-3-105 ED.1 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 3-105: DETAIL SPECIFICATION FOR 4 PAIR BALANCED, INDIVIDUALLY SHIELDED, FIXED AND FREE CONNECTORS WITH CHARACTERISTIC IMPEDENCE OF 100 OHMS, COVERING A FREQUENCY RANGE FROM DC TO 1500 MHZ |
CEI EN 50467 : 2013 | RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS |
04/30112325 DC : DRAFT APR 2004 | IEC 61076-3-104 ED.2 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 3-104: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR 8-WAY, SHIELDED FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 1000 MHZ |
PREN 50467 : DRAFT 2009 | RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS |
I.S. EN 50521:2008 | CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
I.S. EN 62852:2015 | CONNECTORS FOR DC-APPLICATION IN PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
I.S. EN 50548:2011 | JUNCTION BOXES FOR PHOTOVOLTAIC MODULES |
CEI EN 50343 : 2015 | RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING |
BS EN 60603-7 : 2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS |
IEC PAS 61076-3-126:2018 | Connectors for electrical and electronic equipment - Product requirements - Part 3-126: Rectangular connectors - Detail specification for 5 pole power connector for industrial environments with push-pull locking |
IEC PAS 61076-3-110:2002 | Connectors for electronic equipment - Part 3-110: Detail specification for 8 way connectors for frequencies up to 600 MHz |
17/30355792 DC : 0 | BS EN 62790 AMENDMENT 1 - JUNCTION BOXES FOR PHOTOVOLTAIC MODULES - SAFETY REQUIREMENTS AND TESTS |
EN 60603-7:2009/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008/A1:2011) |
11/30244521 DC : 0 | BS EN 61076-3-100 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-110: DETAIL SPECIFICATION FOR SHIELDED, FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 1000 MHZ |
BS EN 62790:2015 | Junction boxes for photovoltaic modules. Safety requirements and tests |
09/30214460 DC : 0 | BS EN 50548 - JUNCTION BOXES FOR PHOTOVOLTAIC MODULES |
I.S. EN 50173-1:2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
CEI EN 61076-4 : 1997 | CONNECTORS WITH ASSESSED QUALITY, FOR USE IN D.C., LOW FREQUENCY ANALOGUE AND IN DIGITAL HIGH-SPEED DATA APPLICATIONS - PART 4: SECTIONAL SPECIFICATION PRINTED BOARD CONNECTORS |
CEI EN 61076-4-108 : 2003 | CONNECTORS FOR ELECTRONIC EQUIPMENT PART 4-108: PRINTED BOARD CONNECTORS WITH ASSESSED QUALITY DETAIL SPECIFICATION FOR CABLE-TO-BOARD CONNECTORS, WITH A MODULAR PITCH OF 25 MM AND INTEGRATED SHIELDING FUNCTION, APPLICABLE FOR TRANSVERSE PACKING DENSITY OF 15 MM, HAVING A BASIC GRID OF 2,5 MM IN ACCORDANCE WITH IEC 60917-1 |
DD CLC/TS 50467:2008 | Railway applications. Rolling stock. Electrical connectors, requirements and test methods |
03/100530 DC : DRAFT JUNE 2003 | IEC 61076-3 ED 2 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 3: RECTANGULAR CONNECTORS - SECTIONAL SPECIFICATION |
BS EN 60352-4:1995 | Solderless connections Solderless non-accessible insulation displacement connections. General requirements, test methods and practical guidance |
04/30124126 DC : DRAFT OCT 2004 | IEC 61076-2-104 ED.1 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 2-104: CIRCULAR CONNECTORS - DETAIL SPECIFICATION FOR M8 CONNECTORS WITH SCREW OR SNAP-LOCKING FOR LOW VOLTAGE APPLICATIONS |
BS EN 50343 : 2014 | RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING |
IEC PAS 60603-7-3:2004 | Connectors for electronic equipment - Part 7-3: Detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 100 MHz |
NF EN 60603-7-3 : DEC 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-3: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 100 MHZ |
IEC PAS 61076-3-104:2002 | Connectors for electronic equipment - Part 3-104: Detail specification for 8-way, shielded free and fixed connectors, for data transmissions with frequencies up to 600 MHz minimum |
EN IEC 61076-2-111:2018 | Connectors for electrical and electronic equipment - Product requirements - Part 2-111: Circular connectors - Detail specification for power connectors with M12 screw-locking |
BS EN 50173-1:2011 | Information technology. Generic cabling systems General requirements |
I.S. EN 61984:2009 | CONNECTORS - SAFETY REQUIREMENTS AND TESTS |
UNE-EN 62790:2015 | Junction boxes for photovoltaic modules - Safety requirements and tests |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
I.S. EN 61076-3-104:2017 | CONNECTORS FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-104: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED FREE AND FIXED CONNECTORS FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 2000 MHZ |
ISO/IEC 15018:2004 | Information technology Generic cabling for homes |
IEC 61076-3-104:2017 | Connectors for electrical and electronic equipment - Product requirements - Part 3-104: Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz |
NF EN 60352-4 : 2001 | SOLDERLESS CONNECTIONS - PART 4: SOLDERLESS NON-ACCESSIBLE INSULATION DISPLACEMENT CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
UNE-EN 50521:2010 | Connectors for photovoltaic systems - Safety requirements and tests |
EN 62790:2015 | Junction boxes for photovoltaic modules - Safety requirements and tests |
EN 60352-4:1994/A1:2000 | SOLDERLESS CONNECTIONS - PART 4: SOLDERLESS NON-ACCESSIBLE INSULATION DISPLACEMENT CONNECTIONS - GENERAL REQUIREMENTS, TEST METHODS AND PRACTICAL GUIDANCE |
EN 61076-4:1996 | Connectors with assessed quality, for use in d.c., low frequency analogue and in digital high-speed data applications - Part 4: Sectional specification - Printed board connectors |
01/207165 DC : DRAFT OCT 2001 | IEC 61076-3-110 ED.1 - CONNECTORS FOR USE IN D.C., LOW FREQUENCY ANALOGUE AND IN DIGITAL HIGH SPEED APPLICATIONS - PART 3-110: DETAIL SPECIFICATION FOR 8 WAY CONNECTORS FOR FREQUENCIES UP TO 600 MHZ [CATEGORY 7 DETAIL SPECIFICATION] |
02/206148 DC : 0 | IEC 60603-7-5. ED. 1.0 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-5: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ (CAT 6, SHIELDED) |
NF EN 60603-7 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS |
NF EN 61076 4 107 : 2002 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 4-107: PRINTED BOARD CONNECTORS WITH ASSESSED QUALITY - DETAIL SPECIFICATION FOR SHIELDED TWO-PART CONNECTORS HAVING A BASIC GRID OF 2,0 MM, FIXED PART WITH SOLDER AND PRESS-IN TERMINATIONS FOR PRINTED BOARDS, FREE PART WITH NON-ACCESSIBLE INSULATION DISPLACEMENT AND CRIMP TERMINATIONS |
CAN/CSA-C22.2 NO. 60947-7-4:18 | Low-voltage switchgear and controlgear ? Part 7-4: Ancillary equipment ? PCB terminal blocks for copper conductors (Trinational standard with NMX-J-538/7-4-ANCE and UL 60974-7-4) |
CEI EN 60947-7-4 : 2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-4: ANCILLARY EQUIPMENT - PCB TERMINAL BLOCKS FOR COPPER CONDUCTORS |
12/30235292 DC : 0 | BS EN 50343 - RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING |
UNE-EN 60947-7-4:2014 | Low-voltage switchgear and controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper conductors |
11/30206085 DC : 0 | BS EN 60947-7-4 - LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-4: ANCILLARY EQUIPMENT - PRINTED BOARD TERMINAL BLOCKS FOR COPPER CONDUCTORS |
16/30325971 DC : 0 | BS ISO/IEC 11801-1 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 1: GENERAL REQUIREMENTS |
NF EN 60603-7-4 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-4: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
BS EN 61076-4-108:2002 | Connectors for electronic equipment. Printed board connectors with assessed quality Detail specification for cable-to-board connectors, with a modular pitch of 25 mm and integrated shielding function, applicable for transverse packing density of 15 mm, having a basic grid of 2,5 mm in accordance with IEC 60917-1 |
03/100336 DC : DRAFT MAR 2003 | IEC 60603-7-7 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-7: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 600 MHZ |
03/100165 DC : DRAFT JAN 2003 | IEC 60603-7-2 ED.1.0 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-2: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSION WITH FREQUENCIES UP TO 100 MHZ |
UL 60947-7-4:1ED 2018-04-27 | Low-Voltage Switchgear and Controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper conductors |
CEI EN 50173-1 : 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
S.R. CLC/TS 50467:2008 | RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS |
I.S. EN 60603-7:2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008) |
BS EN 60947-7-4:2013 | Low-voltage switchgear and controlgear Ancillary equipment. PCB terminal blocks for copper conductors |
I.S. EN 50343:2014 | RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING |
IEC PAS 61076-3-111:2002 | Connectors for electronic equipment - Part 3-111: Detail specification for 8-way, shielded and unshielded, free and fixed connectors, for industrial environments for frequencies up to 250 MHz |
BS EN 61984:2009 | Connectors. Safety requirements and tests |
IEC 61984:2008 | Connectors - Safety requirements and tests |
EN 62852:2015 | Connectors for DC-application in photovoltaic systems - Safety requirements and tests |
05/30128512 DC : DRAFT JAN 2005 | IEC 61984 ED.2 - CONNECTORS - SAFETY REQUIREMENTS AND TESTS |
IEC 61076-4-108:2002 | Connectors for electronic equipment - Part 4-108: Printed board connectors with assessed quality - Detail specification for cable-to-board connectors, with a modular pitch of 25 mm and integrated shielding function, applicable for transverse packing density of 15 mm, having a basic grid of 2,5 mm in accordance with IEC 60917-1 |
IEC 60947-7-4:2013 | Low-voltage switchgear and controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper conductors |
BS EN 62852:2015 | Connectors for DC-application in photovoltaic systems. Safety requirements and tests |
BS EN 50521 : 2009 | CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
08/30179116 DC : DRAFT MAR 2008 | BS EN 50521 - CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
CLC/TS 50467 : 2008 COR 2008 | RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS |
BS EN 61076-5:2001 | Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high speed data applications In-line sockets with assessed quality. Sectional specification |
04/30124122 DC : DRAFT OCT 2004 | IEC 61076-2-101 ED.2 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 2-101: CIRCULAR CONNECTORS. DETAIL SPECIFICATION FOR M12 CONNECTORS WITH SCREW-LOCKING FOR LOW VOLTAGE APPLICATIONS |
BS EN 61076-4-107:2001 | Connectors for electronic equipment Printed board connectors with assessed quality. Detail specification for shielded two-part connectors having a basic grid of 2,0 mm, fixed part with solder and press-in terminations for printed boards, free part with non-accessible insulation displacement and crimp terminations |
09/30213890 DC : 0 | BS EN 61076-3-110 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 3-110: DETAIL SPECIFICATION FOR SHIELDED, FREE AND FIXED CONNECTORSFOR DATA TRANSMISSION WITH FREQUENCIES UP TO 1000 MHZ |
BS EN 50467:2011 | Railway applications. Rolling stock. Electrical connectors, requirements and test methods |
BS EN 61076-3-104:2017 | Connectors for electrical and electronic equipment. Product requirements Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R2015 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
UNE-EN 50548:2012 | Junction boxes for photovoltaic modules |
I.S. EN IEC 61076-2-111:2018 | CONNECTORS FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 2-111: CIRCULAR CONNECTORS - DETAIL SPECIFICATION FOR POWER CONNECTORS WITH M12 SCREW-LOCKING |
ISO/IEC 11801-1:2017 | Information technology — Generic cabling for customer premises — Part 1: General requirements |
PREN 50548 : DRAFT 2009 | JUNCTION BOXES FOR PHOTOVOLTAIC MODULES |
I.S. EN 60947-7-4:2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-4: ANCILLARY EQUIPMENT - PCB TERMINAL BLOCKS FOR COPPER CONDUCTORS (IEC 60947-7-4:2013 (EQV)) |
NF EN 50467 : 2012 | RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS |
UNE-EN 62852:2015 | Connectors for DC-application in photovoltaic systems - Safety requirements and tests |
I.S. EN 61076-4-108:2002 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 4-108: PRINTED BOARD CONNECTORS WITH ASSESSED QUALITY - DETAIL SPECIFICATION FOR CABLE-TO-BOARD CONNECTORS, WITH A MODULAR PITCH OF 25 MM AND INTEGRATED SHIELDING FUNCTION, APPLICABLE FOR TRANSVERSE PACKING DENSITY OF 15 MM, HAVING A BASIC GRID OF 2,5 MM IN ACCORDANCE WITH IEC 60917-1 |
IEC TR 62225:2001 | Guidance on terms for connectors and mechanical structures in electronic equipment |
IEC 62847:2016 | Railway applications - Rolling stock - Electrical connectors - Requirements and test methods |
IEC 61076-5:2001 | Connectors for use in d.c., low-frequency analogue and digital high-speed data applications - Part 5: In-line sockets with assessed quality - Sectional specification |
EN 61076-3-104:2017 | Connectors for electrical and electronic equipment - Product requirements - Part 3-104: Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz |
IEC 62852:2014 | Connectors for DC-application in photovoltaic systems - Safety requirements and tests |
IEC 61076-4:1995 | Connectors with assessed quality, for use in d.c., low-frequency analogue and in digital high-speed data applications - Part 4: Sectional specification - Printed board connectors |
EN 50548 : 2011 AMD 2 2014 | JUNCTION BOXES FOR PHOTOVOLTAIC MODULES |
EN 50521:2008/A1:2012 | CONNECTORS FOR PHOTOVOLTAIC SYSTEMS - SAFETY REQUIREMENTS AND TESTS |
EN 61984:2009 | Connectors - Safety requirements and tests |
EN 61076-4-107:2001 | Connectors for electronic equipment - Part 4-107: Printed board connectors with assessed quality - Detail specification for shielded two-part connectors having a basic grid of 2,0 mm, fixed part with solder and press-in terminations for printed boards, free part with non-accessible insulation displacement and crimp terminations |
EN 50343 : 2014 AMD 1 2017 | RAILWAY APPLICATIONS - ROLLING STOCK - RULES FOR INSTALLATION OF CABLING |
EN 50467:2011 | RAILWAY APPLICATIONS - ROLLING STOCK - ELECTRICAL CONNECTORS, REQUIREMENTS AND TEST METHODS |
EN 60947-7-4 : 2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 7-4: ANCILLARY EQUIPMENT - PCB TERMINAL BLOCKS FOR COPPER CONDUCTORS (IEC 60947-7-4:2013) |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60512-6:1984 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 6: Climatic tests and soldering tests |
IEC 60068-2-60:2015 RLV | Environmental testing - Part 2-60: Tests - Test Ke: Flowing mixed gas corrosion test |
IEC 60512-4:1976 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods. Part 4: Dynamic stress tests |
IEC 60512-5:1992 | Electromechanical components for electronic equipment; basic testing procedures and measuring methods - Part 5: Impact tests (free components), static load tests (fixed components), endurance tests and overload tests |
IEC 60512-1:2001 | Connectors for electronic equipment - Tests and measurements - Part 1: General |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60189-3:2007 | Low-frequency cables and wires with PVC insulation and PVC sheath - Part 3: Equipment wires with solid or stranded conductor wires, PVC insulated, in singles, pairs and triples |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.