IEC 60964:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Nuclear power plants - Control rooms - Design
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
31-12-2021
English - French
23-02-2009
FOREWORD
INTRODUCTION
1 Scope and object
2 Normative references
3 Terms and definitions
4 Standard use
5 Design principles for the main control room
5.1 Main objectives of the main control room
5.2 Functional design objectives of the main control
room
5.3 Safety principles
5.4 Availability principles
5.5 Human factors engineering principles
5.6 Utility operating principles
5.7 Relationship with other control and management
centres
5.8 Operational experience
6 Functional design of the main control room
6.1 General
6.2 Functional analysis
6.2.1 General
6.2.2 Identification of functions
6.2.3 Information flow and processing requirements
6.3 Assignment of functions
6.3.1 General
6.3.2 Operator capabilities
6.3.3 I&C system processing capabilities
6.4 Verification of function assignment
6.4.1 General
6.4.2 Process
6.5 Validation of function assignment
6.5.1 General
6.5.2 Process
6.5.3 General evaluation criteria for validation
6.6 Job analysis
7 Functional design specification
7.1 General
7.2 Provision of data base on human capabilities and
characteristics
7.3 Location, environment and protection
7.3.1 Location
7.3.2 Environment
7.3.3 Protection
7.4 Space and configuration
7.4.1 Space
7.4.2 Configuration
7.5 Panel layout
7.5.1 Priority
7.5.2 Positioning on control desks and panels
7.5.3 Mirror image layout
7.6 Location aids
7.6.1 Grouping of display information and controls
7.6.2 Nomenclature
7.6.3 Coding
7.6.4 Labelling
7.7 Information and control systems
7.7.1 General
7.7.2 Information functions
7.7.3 Control functions
7.8 Control-display integration
7.9 Communication systems
7.9.1 General
7.9.2 Verbal communication systems
7.9.3 Non-verbal communication systems
7.10 Other requirements
7.10.1 Power supplies
7.10.2 Qualification
7.10.3 Maintainability
7.10.4 Repairs
7.10.5 Testability
8 Verification and validation of the integrated control
room system
8.1 General
8.2 Control room system verification
8.2.1 General
8.2.2 Process
8.2.3 General evaluation criteria for integrated
system verification
8.3 Control room system validation
8.3.1 General
8.3.2 Process
8.3.3 General evaluation criteria for integrated
system validation
Annex A (informative) - Explanation of concepts
IEC 60964:2009 provides functional design requirements to be used in the design of the main control room of a nuclear power plant to meet operational and safety requirements. Also provides functional interface requirements which relate to control room staffing, operating procedures, and the training programmes which, together with the human-machine interface, constitute the control room system. This new edition takes into account the fact that software engineering techniques advanced significantly in the intervening years and introduces consistency with the latest revisions of relevant IAEA documents.
DevelopmentNote |
Supersedes IEC TR 61963 and IEC TR 62247. (03/2016) Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
78
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
GOST R IEC 60964 : 2012 | Identical |
NF EN 60964 : 2010 | Identical |
NEN EN IEC 60964 : 2010 | Identical |
I.S. EN 60964:2010 | Identical |
PN EN 60964 : 2010 | Identical |
VDE 0491-5-1 : 2010 | Identical |
DIN EN 60964 : 2010 | Identical |
BS EN 60964:2010 | Identical |
CEI EN 60964 : 2011 | Identical |
EN 60964:2010 | Identical |
UNE-EN 60964:2010 | Identical |
PNE-prEN 60964 | Identical |
NEN 10964 : 1989 | Identical |
09/30176792 DC : 0 | BS EN 61513 - NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - GENERAL REQUIREMENTS FOR SYSTEMS |
BS EN 61226:2010 | Nuclear power plants. Instrumentation and control important to safety. Classification of instrumentation and control functions |
BS IEC 62855:2016 | Nuclear power plants. Electrical power systems. Electrical power systems analysis |
I.S. EN 60709:2010 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - SEPARATION |
BS 7517:1995 | Nuclear power plants. Control rooms. Operator controls |
BS IEC 62118:2000 | Nuclear reactor instrumentation. Pressurized water reactor (PWR) of VVER design. Monitoring adequate cooling within the core during cold shutdown |
DIN EN ISO 11064-5:2008-10 | ERGONOMIC DESIGN OF CONTROL CENTRES - PART 5: DISPLAYS AND CONTROLS |
BS IEC 60965 : 2009 | NUCLEAR POWER PLANTS - CONTROL ROOMS - SUPPLEMENTARY CONTROL POINTS FOR REACTOR SHUTDOWN WITHOUT ACCESS TO THE MAIN CONTROL ROOM |
CEI EN 61772 : 2013 | NUCLEAR POWER PLANTS - CONTROL ROOMS - APPLICATION OF VISUAL DISPLAY UNITS (VDUS) |
NF EN 60709 : 2010 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - SEPARATION |
IEC 62646:2016 | Nuclear power plants - Control rooms - Computer-based procedures |
I.S. EN 61500:2011 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - DATA COMMUNICATION IN SYSTEMS PERFORMING CATEGORY A FUNCTIONS |
I.S. EN 62241:2015 | NUCLEAR POWER PLANTS - MAIN CONTROL ROOM - ALARM FUNCTIONS AND PRESENTATION |
EN IEC 62933-1:2018 | Electrical Energy Storage (EES) systems - Part 1: Vocabulary |
NF EN 60965 : 2016 | NUCLEAR POWER PLANTS - CONTROL ROOMS - SUPPLEMENTARY CONTROL ROOM FOR REACTOR SHUTDOWN WITHOUT ACCESS TO THE MAIN CONTROL ROOM |
IEC TR 62247:2003 | Nuclear power plants - Main control room design - A review of the application of IEC 60964 (1989) |
BS EN ISO 11064-1:2001 | Ergonomic design of control centres Principles for the design of control centres |
EN 61227:2016 | Nuclear power plants - Control rooms - Operator controls |
EN 60965:2016 | Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room |
NF EN 61226 : 2010 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - CLASSIFICATION OF INSTRUMENTATION AND CONTROL FUNCTIONS |
BS IEC 61500 : 2009 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - DATA COMMUNICATION IN SYSTEMS PERFORMING CATEGORY A FUNCTIONS |
04/30042162 DC : DRAFT AUG 2004 | |
IEC 61505:1998 | Nuclear reactor instrumentation - Boiling water reactors (BWR) - Stability monitoring |
BS IEC 61513:2011 | Nuclear power plants. Instrumentation and control important to safety. General requirements for systems |
11/30215545 DC : 0 | BS IEC 62646 - NUCLEAR POWER PLANTS - CONTROL ROOMS - COMPUTER BASED PROCEDURES |
BS IEC 62117:1999 | Nuclear reactor instrumentation. Pressurized light water reactors (PWR). Monitoring adequate cooling within the core during cold shutdown. |
IEC TR 62096:2009 | Nuclear power plants - Instrumentation and control important to safety - Guidance for the decision on modernization |
UNI EN ISO 11064-5 : 2009 | ERGONOMIC DESIGN OF CONTROL CENTRES - PART 5: DISPLAYS AND CONTROLS |
EN 61226:2010 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
I.S. EN 61839:2014 | NUCLEAR POWER PLANTS - DESIGN OF CONTROL ROOMS - FUNCTIONAL ANALYSIS AND ASSIGNMENT |
ISO 11064-5:2008 | Ergonomic design of control centres — Part 5: Displays and controls |
VDE 0491-4 : 2001 | NUCLEAR POWER PLANTS - PRESSURIZED LIGHT WATER REACTORS - MONITORING ADEQUATE COOLING WITHIN THE CORE DURING COLD SHUTDOWN |
BS EN 61513:2013 | Nuclear power plants. Instrumentation and control important to safety. General requirements for systems |
15/30300369 DC : 0 | BS IEC 62646 ED 2.0 - NUCLEAR POWER PLANTS - CONTROL ROOMS - COMPUTER BASED PROCEDURES |
IEC 62933-1:2018 | Electrical energy storage (EES) systems - Part 1: Vocabulary |
16/30331802 DC : 0 | BS EN 62887 ED 1.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION SYSTEMS IMPORTANT TO SAFETY - PRESSURE TRANSMITTERS: CHARACTERISTICS AND TEST METHODS |
BS IEC 62646:2016 | Nuclear power plants. Control rooms. Computer-based procedures |
17/30327241 DC : 0 | BS EN 61500 ED.2 - NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - DATA COMMUNICATION IN SYSTEMS PERFORMING CATEGORY A FUNCTIONS |
07/30135886 DC : 0 | BS IEC 61227 - NUCLEAR POWER PLANTS - CONTROL ROOMS - OPERATOR CONTROLS |
BS EN 62241:2015 | Nuclear power plants. Main control room. Alarm functions and presentation |
15/30298379 DC : 0 | BS EN 60965 ED 3.0 - NUCLEAR POWER PLANTS - CONTROL ROOMS - SUPPLEMENTARY CONTROL ROOM FOR REACTOR SHUTDOWN WITHOUT ACCESS TO THE MAIN CONTROL ROOM |
BS EN 61772:2013 | Nuclear power plants. Control rooms. Application of visual display units (VDUs) |
BS IEC/TR 61838:2001 | Nuclear power plants. Use of probabilistic safety asessment for the classification of instrumentation and control functions |
BS IEC 61839 : 2000 | NUCLEAR POWER PLANTS - DESIGN OF CONTROL ROOMS - FUNCTIONAL ANALYSIS AND ASSIGNMENT |
PD IEC/TR 61838:2009 | Nuclear power plants. Instrumentation and control important to safety. Use of probabilistic safety assessment for the classification of functions |
CEI EN 61500 : 2012 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - DATA COMMUNICATION IN SYSTEMS PERFORMING CATEGORY A FUNCTIONS |
BS IEC 61505:1998 | Nuclear reactor instrumentation. Boiling water reactors (BWR). Stability monitoring |
BS IEC 62241 : 2004 | NUCLEAR POWER PLANTS - MAIN CONTROL ROOM - ALARM FUNCTIONS AND PRESENTATION |
03/305178 DC : DRAFT MAR 2003 | |
NF EN 61772 : 2013 | NUCLEAR POWER PLANTS - CONTROL ROOMS - APPLICATION OF VISUAL DISPLAY UNITS (VDUS) |
03/301759 DC : DRAFT JAN 2003 | IEC 60709 ED.2 - NUCLEAR POWER PLANTS - SEPARATION OF I&C SYSTEMS IMPORTANT TO SAFETY |
03/311284 DC : DRAFT JULY 2003 | IEC 62241 - NUCLEAR POWER PLANTS - MAIN CONTROL ROOM - ALARM FUNCTIONS AND PRESENTATION |
04/19979705 DC : DRAFT SEP 2004 | BS EN ISO 11064-7 - ERGONOMIC DESIGN OF CONTROL CENTRES - PART 7: PRINCIPLES FOR THE EVALUATION OF CONTROL CENTRES |
IEC 62118:2000 | Nuclear reactor instrumentation - Pressurized water reactor (PWR) of VVER design - Monitoring adequate cooling within the core during shutdown |
IEC 61343:1996 | Nuclear reactor instrumentation - Boiling light water reactors (BWR) - Measurements in the reactor vessel for monitoring adequate cooling within the core |
CEI EN 60709 : 2011 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - SEPARATION |
IEC TR 62235:2005 | Nuclear facilities - Instrumentation and control systems important to safety - Systems of interim storage and final repository of nuclear fuel and waste |
IEC TR 61838:2009 | Nuclear power plants - Instrumentation and control important to safety - Use of probabilistic safety assessment for the classification of functions |
I.S. EN 61772:2013 | NUCLEAR POWER PLANTS - CONTROL ROOMS - APPLICATION OF VISUAL DISPLAY UNITS (VDUS) (IEC 61772:2009 (EQV)) |
I.S. EN 61513:2013 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - GENERAL REQUIREMENTS FOR SYSTEMS (IEC 61513:2011 (EQV)) |
CEI EN 60965 : 2012 | NUCLEAR POWER PLANTS - CONTROL ROOMS - SUPPLEMENTARY CONTROL ROOM FOR REACTOR SHUTDOWN WITHOUT ACCESS TO THE MAIN CONTROL ROOM |
IEC 61771:1995 | Nuclear power plants - Main control-room - Verification and validation of design |
IEC 61772:2009 | Nuclear power plants - Control rooms - Application of visual display units (VDUs) |
IEC 61513:2011 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
I.S. EN ISO 11064-3:1999 | ERGONOMIC DESIGN OF CONTROL CENTRES - PART 3: CONTROL ROOM LAYOUT |
I.S. EN 60965:2016 | NUCLEAR POWER PLANTS - CONTROL ROOMS - SUPPLEMENTARY CONTROL ROOM FOR REACTOR SHUTDOWN WITHOUT ACCESS TO THE MAIN CONTROL ROOM |
IEC 60965:2016 | Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room |
BS EN 60965:2016 | Nuclear power plants. Control rooms. Supplementary control room for reactor shutdown without access to the main control room |
16/30331810 DC : 0 | BS IEC 60709 ED 3.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION, CONTROL AND ELECTRICAL SYSTEMS IMPORTANT TO SAFETY - SEPARATION |
17/30356253 DC : 0 | BS EN 62933-1 - ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 1: TERMINOLOGY |
BS IEC 61772:2009 | Nuclear power plants. Control rooms. Application of visual display units (VDUs) |
PD IEC/TR 63084:2017 | Nuclear power plants. Instrumentation and control important to safety. Platform qualification for systems important to safety |
08/30163333 DC : DRAFT SEP 2008 | |
BS EN 61839:2014 | Nuclear power plants. Design of control rooms. Functional analysis and assignment |
CEI EN 61513 : 2013 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - GENERAL REQUIREMENT FOR SYSTEMS |
BS IEC 61226 : 2009 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - CLASSIFICATION OF INSTRUMENTATION AND CONTROL FUNCTIONS |
07/30135889 DC : DRAFT DEC 2007 | IEC 61772 - NUCLEAR POWER PLANTS - CONTROL ROOMS - APPLICATION OF VISUAL DISPLAY UNIT (VDU) |
BS IEC 61227 : 2008 | NUCLEAR POWER PLANTS - CONTROL ROOMS - OPERATOR CONTROLS |
BS IEC/IEEE 62646 : 2012 | NUCLEAR POWER PLANTS - CONTROL ROOMS - COMPUTER BASED PROCEDURES |
I.S. EN IEC 62933-1:2018 | ELECTRICAL ENERGY STORAGE (EES) SYSTEMS - PART 1: VOCABULARY |
I.S. EN ISO 11064-5:2008 | ERGONOMIC DESIGN OF CONTROL CENTRES - PART 5: DISPLAYS AND CONTROLS |
I.S. EN 61226:2010 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - CLASSIFICATION OF INSTRUMENTATION AND CONTROL FUNCTIONS |
BS EN 61500:2011 | Nuclear power plants. Instrumentation and control important to safety. Data communication in systems performing category A functions |
IEC 62117:1999 | Nuclear reactor instrumentation - Pressurized light water reactors (PWR) - Monitoring adequate cooling within the core during cold shutdown |
IEC 62855:2016 | Nuclear power plants - Electrical power systems - Electrical power systems analysis |
IEC 61227:2008 | Nuclear power plants - Control rooms - Operator controls |
ISO 11064-7:2006 | Ergonomic design of control centres — Part 7: Principles for the evaluation of control centres |
ISO 11064-3:1999 | Ergonomic design of control centres — Part 3: Control room layout |
IEC 61839:2000 | Nuclear power plants - Design of control rooms - Functional analysis and assignment |
IEC TR 63084:2017 | Nuclear power plants - Instrumentation and control important to safety - Platform qualification for systems important to safety |
ISO 11064-1:2000 | Ergonomic design of control centres Part 1: Principles for the design of control centres |
IEC 61226:2009 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
BS EN ISO 11064-7:2006 | Ergonomic design of control centres Principles for the evaluation of control centres |
DIN EN ISO 11064-7:2006-08 | Ergonomic design of control centres - Part 7: Principles for the evaluation of control centres (ISO 11064-7:2006) |
EN 61500:2011 | Nuclear power plants - Instrumentation and control important to safety - Data communication in systems performing category A functions |
EN ISO 11064-7:2006 | Ergonomic design of control centres - Part 7: Principles for the evaluation of control centres (ISO 11064-7:2006) |
EN ISO 11064-1:2000 | Ergonomic design of control centres - Part 1: Principles for the design of control centres (ISO 11064-1:2000) |
EN ISO 11064-5:2008 | Ergonomic design of control centres - Part 5: Displays and controls (ISO 11064-5:2008) |
CEI EN 61227 : 1ED 2017 | NUCLEAR POWER PLANTS - CONTROL ROOMS - OPERATOR CONTROLS |
BS EN 61227:2016 | Nuclear power plants. Control rooms. Operator controls |
BS EN 60709:2010 | Nuclear power plants. Instrumentation and control systems important to safety. Separation |
08/30166255 DC : DRAFT JUNE 2008 | |
I.S. EN 61227:2016 | NUCLEAR POWER PLANTS - CONTROL ROOMS - OPERATOR CONTROLS |
BS IEC 60709 : 2004 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - SEPARATION |
BS EN ISO 11064-5:2008 | Ergonomic design of control centres Displays and controls |
PD IEC/TR 62096:2009 | Nuclear power plants. Instrumentation and control important to safety. Guidance for the decision on modernization |
NF EN 61513 : 2013 | NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - GENERAL REQUIREMENTS FOR SYSTEMS |
IEC 61559-2:2002 | Radiation in nuclear facilities - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity - Part 2: Requirements for discharge, environmental, accident, or post-accident monitoring functions |
IEC 62241:2004 | Nuclear power plants - Main control room - Alarm functions and presentation |
EN 61513:2013 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
EN 61772:2013 | Nuclear power plants - Control rooms - Application of visual display units (VDUs) |
EN 62241:2015 | Nuclear power plants - Main control room - Alarm functions and presentation |
EN 61839:2014 | Nuclear power plants - Design of control rooms - Functional analysis and assignment |
EN 60709:2010 | Nuclear power plants - Instrumentation and control systems important to safety - Separation |
IEC 61226:2009 | Nuclear power plants - Instrumentation and control important to safety - Classification of instrumentation and control functions |
IEC 61839:2000 | Nuclear power plants - Design of control rooms - Functional analysis and assignment |
IEC 61772:2009 | Nuclear power plants - Control rooms - Application of visual display units (VDUs) |
IEC 60980:1989 | Recommended practices for seismic qualification of electrical equipment of the safety system for nuclear generating stations |
IEC 61227:2008 | Nuclear power plants - Control rooms - Operator controls |
IEC 60965:2016 | Nuclear power plants - Control rooms - Supplementary control room for reactor shutdown without access to the main control room |
IEC 61771:1995 | Nuclear power plants - Main control-room - Verification and validation of design |
IEC 60960:1988 | Functional design criteria for a safety parameter display system for nuclear power stations |
IEC 60780:1998 | Nuclear power plants - Electrical equipment of the safety system - Qualification |
IEC 61225:2005 | Nuclear power plants - Instrumentation and control systems important to safety - Requirements for electrical supplies |
IEC 61513:2011 | Nuclear power plants - Instrumentation and control important to safety - General requirements for systems |
IEC 60709:2004 | Nuclear power plants - Instrumentation and control systems important to safety - Separation |
IEC 62241:2004 | Nuclear power plants - Main control room - Alarm functions and presentation |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.