IEC 61024-1:1990
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Protection of structures against lightning - Part 1: General principles
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
17-01-2006
English - French, English, French
15-04-1990
Contents
Foreword
Preface
Introduction
Clause
1. General
1.1 Scope and object
1.2 Terms and definitions
1.3 Reinforced concrete structures
2. External lightning protection system (LPS)
2.1 Air termination systems
2.2 Down-conductor systems
2.3 Earth termination systems
2.4 Clamping and joints
2.5 Materials and dimensions
3. Internal lightning protection system
3.1 Equipotential bonding
3.2 Proximity of installations to LPS
3.3 Safeguard against life hazard
4. Design, maintenance and inspection of LPS
4.1 Design
4.2 Maintenance and inspection
Tables
Figures
This standard is applicable to the design and installation of Lightning Protection Systems (LPS) for common structures up to 60 m high.
DocumentType |
Standard
|
Pages |
47
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
PN IEC 61024-1 : 2001 | Identical |
VDE 0185-100 : DRAFT 92 | Corresponds |
ENV 61024-1 : DRAFT 1995 | Corresponds |
DIN V ENV 61024-1 : 1996 | Identical |
NEN NVN ENV 61024-1 : 1995 | Identical |
UNE 21185:1995 | Identical |
VDE V 0185-100 : 1996 | Identical |
00/242566 DC : DRAFT JUN 2000 | |
DIN V ENV 61400-1 : 1996 | WIND TURBINE GENERATOR SYSTEMS - PART 1: SAFETY REQUIREMENTS |
01/204707 DC : DRAFT JUL 2001 | IEC 61000-6-6 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-6: GENERIC STANDARDS - HEMP IMMUNITY FOR INDOOR EQUIPMENT |
95/210789 DC : DRAFT AUG 1995 | IEC 61000-5-6 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5: MITIGATION METHODS AND INSTALLATION GUIDELINES - SECTION 6: MITIGATION OF EXTERNAL INFLUENCES - TECHNICAL REPORT TYPE 2 |
IEEE 142 : 2007 | GROUNDING OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
03/523672 DC : DRAFT MAR 2003 | IEC TS 60479-4 ED.1.0 - EFFECTS OF CURRENT ON HUMAN BEINGS AND LIVESTOCK - PART 4: EFFECTS OF LIGHTNING STROKES ON HUMAN BEINGS AND LIVESTOCK |
BS EN 61822:2009 | Electrical installations for lighting and beaconing of aerodromes. Constant current regulators |
BS IEC 61000-6-6:2003 | Electromagnetic compatibility (EMC) Generic standards - HEMP immunity for indoor equipment |
PD IEC/TR 62066:2002 | Surge overvoltages and surge protection in low-voltage a.c. power systems. General basic information |
IEC TR 62066:2002 | Surge overvoltages and surge protection in low-voltage a.c. power systems - General basic information |
97/205962 DC : DRAFT MAY 1997 | PREN 50280 - SMALL TRANSMITTING/RECEIVING ANTENNA SYSTEMS - SAFETY REQUIREMENTS |
I.S. EN 61000-4-25:2002 | ELECTROMAGNETIC COMPATIBILITY (EMC) - TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS (IEC 61000-4-25:2001 (EQV)) |
S.R. HD 60364-5-51:2009 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES |
I.S. HD 60364-7-705:2007 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - - PART 7-705: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - AGRICULTURAL AND HORTICULTURAL PREMISES (IEC 60364-7-705:2006 (MOD)) |
DIN EN 13135-1:2011-04 | CRANES - EQUIPMENT - PART 1: ELECTROTECHNICAL EQUIPMENT |
HD 384.5.51 : 200S2 | ELECTRICAL INSTALLATION OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - CHAPTER 51: COMMON RULES |
EN 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
HD 60364-5-51:2009/A12:2017 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES |
EN 12391-1:2003 | Chimneys - Execution standard for metal chimneys - Part 1: Chimneys for non-roomsealed heating appliances |
EN 61822:2009 | ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - CONSTANT CURRENT REGULATORS |
DIN EN 12976-1:2017-04 | Thermal solar systems and components - Factory made systems - Part 1: General requirements |
EN 13213:2001 | Hollow floors |
NBR IEC 61400-1 : 2008 | WIND TURBINES - PART 1: DESIGN REQUIREMENTS |
IEC TS 61312-3:2000 | Protection against lightning electromagnetic impulse - Part 3: Requirements of surge protective devices (SPDs) |
BIS IS/IEC 60479-4 : 2004 | EFFECTS OF CURRENT ON HUMAN BEINGS AND LIVESTOCK - PART 4: EFFECTS OF LIGHTNING STROKES ON HUMAN BEINGS AND LIVESTOCK |
BS EN 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust Selection and installation |
I.S. EN 61241-14:2004 | ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 14: SELECTION AND INSTALLATION |
NF EN 50090-9-1 : 2004 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 9-1: INSTALLATION REQUIREMENTS - GENERIC CABLING FOR HBES CLASS 1 TWISTED PAIR |
12/30257357 DC : 0 | BS EN 12976-2 - THERMAL SOLAR SYSTEMS AND COMPONENTS - FACTORY MADE SYSTEMS - PART 2: TEST METHODS |
PD IEC/TR 61400-24:2002 | Wind turbine generator systems Lightning protection |
BS IEC 61000-5.1 : 1996 | |
BS IEC 61000-5.2 : 1997 | |
DD IEC TS 62257-5 : DRAFT 2005 | RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 5: PROTECTION AGAINST ELECTRICAL HAZARDS |
PREN 12976-1 : DRAFT 2014 | THERMAL SOLAR SYSTEMS AND COMPONENTS - FACTORY MADE SYSTEMS - PART 1: GENERAL REQUIREMENTS |
03/306253 DC : DRAFT MAY 2003 | IEC 60728-11 - CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 11: SAFETY REQUIREMENTS |
97/202078 DC : DRAFT FEB 1997 | IEC 61819 - TEST PARAMETERS SIMULATING THE EFFECTS ON LIGHTNING PROTECTION SYSTEMS (L.P.S.) COMPONENTS |
IEC 60364-4-444:1996 | Electrical installations of buildings - Part 4: Protection for safety - Section 444: Protection against electromagnetic interferences (EMI) in installations of buildings |
IEC TR 61200-704:1996 | Electrical installation guide - Part 704: Construction and demolition site installations |
IEC 60364-4-443:1995+AMD1:1998 CSV | Electrical installations of buildings - Part 4: Protection for safety - Chapter 44: Protection against overvoltages - Section 443: Protection against overvoltages of atmospheric origin or due to switching |
IEC TR 61000-5-2:1997 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 2: Earthing and cabling |
04/30125642 DC : DRAFT NOV 2004 | IEC 61643-12 ED.2 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - SELECTION AND APPLICATION PRINCIPLES |
DIN V VDE V 0800-2-548 : 1999 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SECTION 548: EARTHING ARRANGEMENTS AND EQUIPOTENTIAL BONDING FOR INFORMATION TECHNOLOGY INSTALLATIONS |
DIN EN 13135-1:2004-05 | CRANES - EQUIPMENT - PART 1: ELECTROTECHNICAL EQUIPMENT |
I.S. EN 12976-1:2017 | THERMAL SOLAR SYSTEMS AND COMPONENTS - FACTORY MADE SYSTEMS - PART 1: GENERAL REQUIREMENTS |
EN 60079-14:2014/AC:2016 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION (IEC 60079-14:2013/COR1:2016) |
DIN EN 61663-1 : 2000 | LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1: FIBRE OPTIC INSTALLATIONS |
VDE 0845-4-1 : 2000 | LIGHTING PROTECTION - TELECOMMUNICATION LINES - FIBRE OPTIC INSTALLATIONS A FIBRES OPTIQUES |
06/30146388 DC : DRAFT FEB 2006 | CENELEC TS 61643-12 - LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 12: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - SELECTION AND APPLICATION PRINCIPLES |
12/30257354 DC : 0 | BS EN 12976-1 - THERMAL SOLAR SYSTEMS AND COMPONENTS - FACTORY MADE SYSTEMS - PART 1: GENERAL REQUIREMENTS |
BS EN 61000-4-25 : 2002 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-25: TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS |
03/318811 DC : DRAFT NOV 2003 | IEC 62257-5 TS ED.1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 5: SAFETY RULES - PROTECTION AGAINST ELECTRICAL HAZARDS |
PD IEC TR 61000-5-6:2002 | Electromagnetic compatibility (EMC). Installation and mitigation guidelines Mitigation of external EM influences |
03/103069 DC : DRAFT JAN 2003 | |
DD ENV 61400-1:1995 | Wind turbine generator systems Safety requirements |
BS Z 100:1999 | Space systems. Ground support equipment for use at launch, landing, or retrieval sites. General requirements |
BS EN 61663-1:2000 | Lightning protection. Telecommunication lines Fibre optic installations |
IEC 61000-6-6:2003 | Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment |
PD 6580-2:1995 | Home and building electronic systems. Technical report 1 Guidelines for the professional installation of Twisted Pair cables class 1 |
HD 60364-7-705:2007/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-705: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - AGRICULTURAL AND HORTICULTURAL PREMISES |
IEC TS 61312-2:1999 | Protection against lightning electromagnetic impulse (LEMP) - Part 2: Shielding of structures, bonding inside structures and earthing |
IEC 60364-5-51:2005 | Electrical installations of buildings - Part 5-51: Selection and erection of electrical equipment - Common rules |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC 61312-1:1995 | Protection against lightning electromagnetic impulse - Part 1: General principles |
CEI EN 50090-9-1 : 2005 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 9-1: INSTALLATION REQUIREMENTS - GENERIC CABLING FOR HBES CLASS 1 TWISTED PAIR |
I.S. HD 384.5.51:1998 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - CHAPTER 51: COMMON RULES |
CSA C61400-24 : 2007 | WIND TURBINE GENERATOR SYSTEMS - PART 24: LIGHTNING PROTECTION |
IEC 61024-1-2:1998 | Protection of structures against lightning - Part 1-2: General principles - Guide B - Design, installation, maintenance and inspection of lightning protection systems |
DIN EN 12976-1:2014-07 (Draft) | THERMAL SOLAR SYSTEMS AND COMPONENTS - FACTORY MADE SYSTEMS - PART 1: GENERAL REQUIREMENTS |
UNE-EN 60079-14:2016 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
04/30119272 DC : DRAFT SEP 2004 | IEC TS 62257-7-1 - RECOMMENDATION FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 7-1: GENERATORS - PHOTOVOLTAIC ARRAYS |
IEC 61241-14:2004 | Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installation |
BS EN 60079-14:2014 | Explosive atmospheres Electrical installations design, selection and erection |
EN 12976-1:2017 | Thermal solar systems and components - Factory made systems - Part 1: General requirements |
UNI EN 13135-1 : 2010 | CRANES - EQUIPMENT - PART 1: ELECTROTECHNICAL EQUIPMENT |
IEC TR 61000-5-1:1996 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 1: General considerations - Basic EMC publication |
00/241233 DC : 0 | IEC 61312-5 - PROTECTION AGAINST LIGHTNING ELECTROMAGNETIC IMPULSE (LEMP) - PART 5: APPLICATION GUIDE |
IEC TR 61000-5-6:2002 | Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences |
04/30124138 DC : DRAFT OCT 2004 | IEC 60364-5-53 ED.4 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL |
IEC TR 61400-24:2002 | Wind turbine generator systems - Part 24: Lightning protection |
DIN VDE 0185-103 : 1997 | PROTECTION AGAINST LIGHTNING ELECTROMAGNETIC IMPULSE - PART 1: GENERAL PRINCIPLES |
IEC 60364-5-548:1996+AMD1:1998 CSV | Electrical installations of buildings - Part 5: Selection and erection of electrical equipment - Section 548: Earthing arrangements and equipotential bonding for information technology installations |
I.S. HD 60364-5-51:2009 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-51: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - COMMON RULES (IEC 60364-5-51:2005 (MOD)) |
IEC TS 61312-4:1998 | Protection against lightning electromagnetic impulse - Part 4: Protection of equipment in existing structures |
UNE-EN 61822:2011 | Electrical installations for lighting and beaconing of aerodromes - Constant current regulators |
I.S. HD 60364-5-534:2008 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL - CLAUSE 534: DEVICES FOR PROTECTION AGAINST OVERVOLTAGES |
IEC 61000-4-25:2001+AMD1:2012 CSV | Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems |
I.S. EN 61822:2009 | ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - CONSTANT CURRENT REGULATORS |
BS EN 12976-1:2017 | Thermal solar systems and components. Factory made systems General requirements |
BS EN 13135-1 : 2003 | CRANES - EQUIPMENT - PART 1: ELECTROTECHNICAL EQUIPMENT |
12/30266531 DC : 0 | BS EN TS 62257-1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 1: GENERAL INTRODUCTION TO RURAL ELECTRIFICATION |
05/30138005 DC : DRAFT AUG 2005 | IEC 60079-14 ED 4 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS IN HAZARDOUS AREAS (OTHER THAN MINES) |
97/200935 DC : DRAFT JAN 1997 | IEC 60364 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - REVISION OF CHAPTER 54: EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
EN 61000-4-25 : 2002 AMD 1 2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-25: TESTING AND MEASUREMENT TECHNIQUES - HEMP IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS (IEC 61000-4-25:2001/A1:2012) |
IEC 61663-1:1999 | Lightning protection - Telecommunication lines - Part 1: Fibre optic installations |
BS EN 12391-1:2003 | Chimneys. Execution standard for metal chimneys Chimneys for non-roomsealed heating appliances |
DD ENV 12977-1:2001 | Thermal solar systems and components. Custom built systems General requirements |
03/109124 DC : DRAFT JUNE 2003 | IEC 61400-1 ED.3.0 - WIND TURBINES - PART 1: DESIGN REQUIREMENTS |
IEC 60364-5-534:1997 | Electrical installations of buildings - Part 5: Selection and erection of electrical equipment - Section 534: Devices for protection against overvoltages |
CEI EN 61663-1 : 2000 | LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1: FIBRE OPTIC INSTALLATIONS |
14/30298615 DC : 0 | BS EN 12976-1 - THERMAL SOLAR SYSTEMS AND COMPONENTS - FACTORY MADE SYSTEMS - PART 1: GENERAL REQUIREMENTS |
API/EI 545-A : 2009 | VERIFICATION OF LIGHTNING PROTECTION REQUIREMENTS FOR ABOVE GROUND HYDROCARBON STORAGE TANKS |
I.S. EN 60079-14:2014 | EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION |
IEC 61822:2009 | Electrical installations for lighting and beaconing of aerodromes - Constant current regulators |
12/30269297 DC : 0 | BS EN 60079-14/ED 5 - EXPLOSIVE ATMOSPHERES - PART 14: ELECTRICAL INSTALLATIONS DESIGN, SELECTION AND ERECTION |
EN 13135-1:2003+A1:2010 | Cranes - Equipment - Part 1: Electrotechnical equipment |
EN 61663-1 : 1999 | LIGHTNING PROTECTION - TELECOMMUNICATION LINES - PART 1 - FIBRE OPTIC INSTALLATIONS |
EN 12825:2001 | Raised access floors |
SA TR 61000.5.2:2019 | Electromagnetic compatibility (EMC) Installation and mitigation guidelines - Section 2: Earthing and cabling (IEC TR 61000-5-2:1997 ED 1.0 (MOD)) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.