• IEC 61952:2008

    Current The latest, up-to-date edition.

    Insulators for overhead lines - Composite line post insulators for A.C. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French, Spanish, Castilian

    Published date:  27-05-2008

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    FOREWORD
    INTRODUCTION
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Abbreviations
    5 Identification
    6 Environmental conditions
    7 Transport, storage and installation
    8 Tolerances
    9 Classification of tests
       9.1 Design tests
       9.2 Type tests
       9.3 Sample tests
       9.4 Routine tests
    10 Design tests
       10.1 General
       10.2 Test specimens for IEC 62217
            10.2.1 Tests on interfaces and connections of end fittings
            10.2.2 Tracking and erosion test
            10.2.3 Tests on core material
       10.3 Product specific pre-stressing for IEC 62217 tests on
            interfaces and connections of end fittings
            10.3.1 Thermal-mechanical pre-stressing
       10.4 Assembled core load tests
            10.4.1 Test for the verification of the maximum design
                   cantilever load (MDCL)
            10.4.2 Tensile load test
    11 Type tests
       11.1 Electrical tests
            11.1.1 Vertical mounting arrangement
            11.1.2 Horizontal mounting arrangement
       11.2 Mechanical tests
            11.2.1 Cantilever failing load test
    12 Sample tests
       12.1 General rules
       12.2 Verification of dimensions (E1 + E2)
       12.3 Galvanizing test (E1 + E2)
       12.4 Verification of the SCL (E1)
            12.4.1 Test procedure
            12.4.2 Acceptance criteria
       12.5 Re-testing procedure
    13 Routine tests
       13.1 Tensile load test
       13.2 Visual examination
    Annex A (informative) Notes on the mechanical loads
            and tests
    Annex B (informative) Determination of the equivalent
            bending moment caused by combined loads
    Bibliography

    Abstract - (Show below) - (Hide below)

    IEC 61952:2008 applies to composite line post insulators consisting of a load-bearing, cylindrical, insulating solid core made up of fibres - usually glass - in a resin-based matrix, a housing (outside the insulating core) made of elastomer material (e.g. silicone or ethylene-propylene) and end fittings permanently attached to the insulating core. The object of this standard is to
    - define the terms used,
    - prescribe test methods,
    - prescribe acceptance or failure criteria.
    This standard does not include requirements dealing with the choice of insulators for specific operating conditions. This edition includes the following significant technical changes with respect to the previous edition:
    - removal of tests procedures now given in IEC 62217;
    - inclusion of clauses on tolerances, environmental conditions, transport, storage and installation;
    - changes in the parameters determining the need to repeat design and type tests; and
    - modification of the specification of load application in bending tests to simplify testing.

    General Product Information - (Show below) - (Hide below)

    Committee TC 36
    Development Note Stability Date: 2018. (09/2017)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    CEI EN 62231 : 2007 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
    PD IEC/TR 62730:2012 HV polymeric insulators for indoor and outdoor use tracking and erosion testing by wheel test and 5 000h test
    PREN 50119 : DRAFT 2017 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    NF EN 62621 : 2017 AMD 1 2018 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS
    NF EN 50151 : 2004 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS
    BS EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV General requirements. Common specifications
    EN 62231:2006 Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria
    EN 50151 : 2003 COR 2010 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS
    NBR 7282 : 2011 HIGH-VOLTAGE FUSES - EXPULSION TYPE FUSES - REQUIREMENTS AND TEST METHODS
    EN 50423-1:2005 Overhead electrical lines exceeding AC 1 kV up to and including AC 45 kV - Part 1: General requirements - Common specifications
    I.S. EN 50151:2003 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIAL REQUIREMENTS FOR COMPOSITE INSULATORS
    11/30215604 DC : 0 BS IEC 60913 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    17/30341013 DC : DRAFT AUG 2017 BS EN 50119 - RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    BS EN 62621 : 2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS (IEC 62621:2011)
    I.S. EN 62231:2007 COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1 000 V UP TO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
    I.S. EN 50341-1:2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
    EN 50341-1:2012 Overhead electrical lines exceeding AC 1 kV - Part 1: General requirements - Common specifications
    I.S. EN 50119:2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    ANSI C29.11 : 2012 COMPOSITE SUSPENSION INSULATORS FOR OVERHEARD TRANSMISSION LINES - TESTS
    BS EN 50423-1:2005 Overhead electrical lines exceeding AC 1 kV up to and including AC 45 kV General requirements. Common specifications
    BS EN 50341-2-4:2016 Overhead electrical lines exceeding AC 1 kV National Normative Aspects (NNA) for Germany (based on EN 50341-1:2012)
    CEI EN 50341-1 : 2013 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
    IEC 60913:2013 Railway applications - Fixed installations - Electric traction overhead contact lines
    IEC 60282-2:2008 High-voltage fuses - Part 2: Expulsion fuses
    12/30260570 DC : 0 BS EN 50341-1 - OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
    02/206403 DC : DRAFT MAY 2002 IEC 62231. ED.1.0 - COMPOSITE STATION POST INSULATORS FOR SUBSTATIONS WITH A.C. VOLTAGES GREATER THAN 1000 V UPTO 245 KV - DEFINITIONS, TEST METHODS AND ACCEPTANCE CRITERIA
    IEC TS 62896:2015 Hybrid insulators for a.c. and d.c. for high-voltage applications - Definitions, test methods and acceptance criteria
    PD IEC/TS 62896:2015 Hybrid insulators for a.c. and d.c. high-voltage applications. Definitions, test methods and acceptance criteria
    BS EN 62231:2007 Composite station post insulators for substations with a.c. voltages greater than 1000 V up to 245 kV. Definitions, test methods and acceptance criteria
    I.S. EN 50423-1:2005 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV UP TO AND INCLUDING AC 45 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
    EN 50341-2-4:2016 Overhead electrical lines exceeding AC 1 kV - Part 2-4: National Normative Aspects (NNA) for Germany (based on EN 50341-1:2012)
    BS EN 50151:2003 Railway applications. Fixed installations. Electric traction. Special requirements for composite insulators
    IEC TR 62730:2012 HV polymeric insulators for indoor and outdoor use tracking and erosion testing by wheel test and 5 000h test
    IEC 62621:2011 Railway applications - Fixed installations - Electric traction - Specific requirements for composite insulators used for overhead contact line systems
    I.S. EN 50119:2020 Railway applications - Fixed installations - Electric traction overhead contact lines
    UNE-EN 62621:2016 Railway applications - Fixed installations - Electric traction - Specific requirements for composite insulators used for overhead contact line systems
    IEC 62231:2006 Composite station post insulators for substations with a.c. voltages greater than 1 000 V up to 245 kV - Definitions, test methods and acceptance criteria
    EN 50119 : 2009 AMD 1 2013 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    PREN 50341-1 : DRAFT 2012 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 1: GENERAL REQUIREMENTS - COMMON SPECIFICATIONS
    BS EN 50119 : 2009 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES
    17/30337860 DC : 0 BS EN 61952-1 - INSULATORS FOR OVERHEAD LINES - COMPOSITE LINE POST INSULATORS FOR A.C SYSTEMS WITH A NOMINAL VOLTAGE GREATER THAN 1000 V - PART 1: DEFINITIONS, END FITTINGS AND DESIGNATIONS
    I.S. EN 62621:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS
    I.S. EN 50341-2-4:2016 OVERHEAD ELECTRICAL LINES EXCEEDING AC 1 KV - PART 2-4: NATIONAL NORMATIVE ASPECTS (NNA) FOR GERMANY (BASED ON EN 50341-1:2012)
    EN 62621:2016/A1:2016 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION - SPECIFIC REQUIREMENTS FOR COMPOSITE INSULATORS USED FOR OVERHEAD CONTACT LINE SYSTEMS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 61467:2008 Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
    IEC 60050-471:2007 International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
    IEC 62217:2012 Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
    IEC 60383-1:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units for a.c. systems - Definitions, test methods and acceptance criteria
    ISO 3452:1984 Non-destructive testing — Penetrant inspection — General principles
    IEC 61462:2007 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations
    IEC GUIDE 111:2004 Electrical high-voltage equipment in high-voltage substations - Common recommendations for product standards
    IEC 60507:2013 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
    IEC 60383-2:1993 Insulators for overhead lines with a nominal voltage above 1000 V - Part 2: Insulator strings and insulator sets for a.c. systems - Definitions, test methods and acceptance criteria
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective