FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Limits of supply
   4.1 General
   4.2 Over-voltage protection
5 Rating
   5.1 General
   5.2 Rated voltage
   5.3 Rated insulation level
   5.4 Rated normal current and temperature rise
   5.5 Rated short-time and peak withstand currents and
       rated duration of short circuit
   5.6 Rated filling pressure of insulating gas in the
       cable connection enclosure
6 Design and construction requirements
   6.1 Pressure withstand requirements
   6.2 Mechanical forces on cable-terminations
7 Standard dimensions
   7.1 Fluid-filled cable-terminations
   7.2 Dry-type cable-terminations
   7.3 Three-phase cable-termination enclosure
8 Tests
   8.1 General
   8.2 Dielectric type tests of cable-terminations
       8.2.1 General
       8.2.2 Dielectric type test of cable-terminations
             in a single phase enclosure
       8.2.3 Dielectric type test of cable-termination in
             a three phase enclosure
   8.3 Tests after cable system installation
9 Information to be given with enquiries, tenders and orders
10 Rules for transport, storage, erection, operation and
   maintenance

This standard covers the connection assembly of fluid-filled and extruded cables to gas-insulated metal enclosed switchgear (GIS), in single- or three-phase arrangements where the cable-terminations are fluid-filled or dry type and there is a separating insulating barrier between the cable insulation and the gas insulation of the switchgear.

Committee
TC 17/SC 17C
DevelopmentNote
Supersedes IEC TS 60859. (08/2007) Stability Date: 2017. (10/2012)
DocumentType
Standard
Pages
32
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

UNE-EN 62271-205:2011 High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV
PD IEC/TR 63042-100:2016 UHV AC transmission systems General information
BS EN 62271-203:2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
NF EN 62271-205 : 2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
UNE-EN 62271-203:2013 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 62271-205:2008/corrigendum:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
EN 62271-211:2014/AC:2017-09 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 211: DIRECT CONNECTION BETWEEN POWER TRANSFORMERS AND GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-211:2014/COR2:2017)
I.S. EN 62271-203:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-203:2011 (EQV))
BS EN 62271-211:2014 High-voltage switchgear and controlgear Direct connection between power transformers and gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
I.S. EN 62271-211:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 211: DIRECT CONNECTION BETWEEN POWER TRANSFORMERS AND GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
UNE-EN 50299-2:2015 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations
08/30179468 DC : DRAFT MAR 2008 BS EN 62271-203 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
BS EN 50299-2:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Dry-type cable terminations
I.S. EN 62271-205:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
BS EN 50299-1:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV Fluid-filled cable terminations
UNE-EN 50299-1:2015 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 1: Fluid-filled cable terminations
I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
12/30240226 DC : 0 BS EN 62271-211 ED 1.0 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 211: DIRECT CONNECTION BETWEEN POWER TRANSFORMERS AND GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
I.S. EN 50299-2:2014 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS
IEEE C37.123-1996 IEEE Guide to Specifications for Gas-Insulated, Electric Power Substation Equipment
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
CEI EN 62271-205 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
IEC TR 63042-100:2016 UHV AC transmission systems - Part 100: General information
IEC 62271-205:2008 High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV
CEI EN 62271-203 : 2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 203: GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES ABOVE 52 KV
BS EN 62271-205:2008 High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV
13/30281716 DC : 0 BS EN 50299-2 - OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT U[M] FROM 72,5 KV TO 550 KV - PART 2: DRY-TYPE CABLE TERMINATIONS
IEEE C37.122.1-2014 IEEE Guide for Gas-Insulated Substations Rated Above 52 kV
I.S. EN 50299-1:2014 OIL-IMMERSED CABLE CONNECTION ASSEMBLIES FOR TRANSFORMERS AND REACTORS HAVING HIGHEST VOLTAGE FOR EQUIPMENT UM FROM 72,5 KV TO 550 KV - PART 1: FLUID-FILLED CABLE TERMINATIONS
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 50299-1:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 1: Fluid-filled cable terminations
EN 50299-2:2014 Oil-immersed cable connection assemblies for transformers and reactors having highest voltage for equipment Um from 72,5 kV to 550 kV - Part 2: Dry-type cable terminations
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV

IEC 60038:2009 IEC standard voltages
IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC 60141-1:1993 Tests on oil-filled and gas-pressure cables and their accessories - Part 1: Oil-filled, paper or polypropylene paper laminate insulated, metal-sheathed cables and accessories for alternating voltages up to and including 500 kV

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.