1 Overview
1.1 Scope
1.2 Purpose
2 References
3 Definitions and symbols
3.1 Definitions
3.2 Symbols
4 General
4.1 Preliminary evaluation
4.2 Cooling equipment operation
5 Precautions
5.1 Thermal degradation
5.2 Other factors limiting loading
5.3 Monitoring of test results
5.4 Maximum temperatures
6 Monitored data
6.1 Ambient air temperature
6.2 Oil temperatures
6.3 Other temperatures
6.4 Currents
7 Recorded data
7.1 Losses
7.2 Temperature indicator readings
7.3 Tank surface and other temperatures
7.4 Oil levels
8 Oil samples
9 Test procedure for determining the thermal characteristics of
oil-immersed power transformers
9.1 Tap position and connection
9.2 Number of tests
9.3 Applied test currents
9.4 Discontinued tests
9.5 Temperature rise test at rated load
9.6 Temperature rise test at reduced load
9.7 Temperature rise test at load beyond nameplate rating
9.8 Evaluation of thermal data
9.9 Evaluation of other data
10 Test procedure for performing load cycle temperature rise tests
10.1 Recommended prior tests
10.2 Information specified by user
10.3 Determination of load cycle
10.4 Preparatory calculations
10.5 Data recorded
10.6 Test procedure
10.7 Interrupted test
10.8 Assessment of transformer performance
11 Integrated test procedure for determining thermal characteristics
and for performing load cycle temperature rise tests
11.1 Load cycle simulation
11.2 Preliminary evaluation
11.3 Test procedure
11.4 Initial test
11.5 Conditioning load
11.6 Beyond maximum nameplate test
11.7 Final test
Annex A (normative) Loading guide equations
Annex B (informative) Tutorial
Annex C (informative) Hottest spot measurements using direct reading
fiber optics temperature measurements
Annex D (informative) Bibliography
Covers temperature rise test procedures for determining those thermal characteristics of power transformers needed to appraise the transformer's load carrying capabilities at specific loading conditions other than rated load.
Committee |
Transformers
|
DevelopmentNote |
Supersedes IEEE DRAFT C57.119. (11/2001)
|
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
Institute of Electrical & Electronics Engineers
|
Status |
Superseded
|
SupersededBy |
IEEE DRAFT C57.130 : D17 2006 | GUIDE FOR THE USE OF DISSOLVED GAS ANALYSIS DURING FACTORY TEMPERATURE RISE TESTS FOR THE EVALUATION OF OIL-IMMERSED TRANSFORMERS AND REACTORS |
IEC 60076-7:2018 | Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers |
IEEE C57.91-2011 REDLINE | IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators |
C88-16 | Power transformers and reactors |
IEEE C57.12.10-2010 | TRANSFORMERS - 230 KV AND BELOW 833/958 THROUGH 8333/10 417 KVA, SINGLE-PHASE, AND 750/862 THROUGH 60 000/80 000/100 000 KVA, THREE-PHASE WITHOUT LOAD TAP CHANGING; AND 3750/4687 THROUGH 60 000/80 000/100 000 KVA WITH LOAD TAP CHANGING - SAFETY REQUIREMENT |
IEEE C57.12.00-2015 | IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEEE C57.91-2011 REDLINE | IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators |
IEC 60354:1991 | Loading guide for oil-immersed power transformers |
IEEE DRAFT C57.130 : D17 2006 | GUIDE FOR THE USE OF DISSOLVED GAS ANALYSIS DURING FACTORY TEMPERATURE RISE TESTS FOR THE EVALUATION OF OIL-IMMERSED TRANSFORMERS AND REACTORS |
IEEE C57.12.90-2010 | IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers |
IEEE C57.104-2008 | IEEE Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers |
IEEE C57.92-1981 | IEEE Guide for Loading Mineral-Oil-Immersed Power Transformers Up to and Including 100 MVA with 55 C or 65 C Average Winding Rise |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.