• IEEE C57.154-2012

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    IEEE Standard for the Design, Testing, and Application of Liquid-Immersed Distribution, Power, and Regulating Transformers Using High-Temperature Insulation Systems and Operating at Elevated Temperatures

    Available format(s):  PDF

    Superseded date:  25-08-2022

    Language(s):  English

    Published date:  30-10-2012

    Publisher:  Institute of Electrical & Electronics Engineers

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1. Overview
    2. Normative references
    3. Definitions
    4. Insulation systems
    5. Temperature limits
    6. Transformer accessories
    7. Special design considerations
    8. Required information
    9. Nameplate and additional information
    10. Test
    Annex A (informative) - Insulation materials
    Annex B (informative) - Ester liquid and cellulose paper
    Annex C (informative) - Supervision, diagnostics, and
            maintenance
    Annex D (informative) - Bibliography

    Abstract - (Show below) - (Hide below)

    This standard applies to all liquid-immersed distribution, power, and regulating transformers that are designed to operate at temperatures that exceed the normal thermal limits of IEEE Std C57.12.00TM under continuous load, in the designed average ambient, and at rated conditions.

    General Product Information - (Show below) - (Hide below)

    Committee Transformers
    Document Type Standard
    Publisher Institute of Electrical & Electronics Engineers
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    IEEE/IEC 60076-16-2018 IEC/IEEE International Standard - Power transformers - Part 16: Transformers for wind turbine applications
    IEEE C57.12.24-2009 IEEE Standard for Submersible, Three-Phase Transformers, 3750 kVA and Smaller: High Voltage, 34 500 GrdY/19 920 Volts and Below; Low Voltage, 600 Volts and Below
    IEEE C57.163-2015 IEEE Guide for Establishing Power Transformer Capability while under Geomagnetic Disturbances
    IEEE C57.19.04-2018 IEEE Standard for Performance Characteristics and Dimensions for High Current Power Transformer Bushings with Rated Continuous Current in Excess of 5000 A in Bus Enclosures
    IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
    C88-16 Power transformers and reactors
    IEEE 1276-2020 REDLINE IEEE Guide for the Application of High-Temperature Insulation Materials in Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE C57.12.23-2018 REDLINE IEEE Standard for Submersible Single-Phase Transformers:250 kVA and Smaller; High Voltage 34 500 GrdY/19 920 V and Below; Low Voltage 600 V and Below
    IEEE C57.12.24-2016 REDLINE IEEE Standard for Submersible, Three-Phase Transformers, 3750 kVA and Smaller: High Voltage, 34 500 GrdY/19 920 Volts and Below; Low Voltage, 600 Volts and Below

    Standards Referencing This Book - (Show below) - (Hide below)

    NEMA MW 1000 : 2016 MAGNET WIRE
    IEEE C57.19.100-2012 REDLINE IEEE Guide for Application of Power Apparatus Bushings
    IEEE C57.19.03-1996 IEEE Standard Requirements, Terminology, and Test Code for Bushings for DC Applications
    IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE C57.19.00 : 2004 GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS
    IEEE C57.91-2011 REDLINE IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators
    IEEE C57.12.00-2010 REDLINE IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
    ASTM D 1305 : 2016 : REDLINE Standard Specification for Electrical Insulating Paper and Paperboard—Sulfate (Kraft) Layer Type
    IEEE C57.12.80-2010 IEEE Standard Terminology for Power and Distribution Transformers
    IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
    IEEE C57.111 : 1989 GUIDE FOR ACCEPTANCE OF SILICONE INSULATING FLUID AND ITS MAINTENANCE IN TRANSFORMERS
    IEEE C57.19.0:2005 STANDARD REQUIREMENTS, TERMINOLOGY, AND TEST CODE FOR BUSHINGS FOR DC APPLICATIONS
    IEEE C57.129-2007 REDLINE IEEE Standard for General Requirements and Test Code for Oil-Immersed HVDC Converter Transformers
    ASTM D 93 : 2016-07 TEST METHODS FOR FLASH POINT BY PENSKY-MARTENS CLOSED CUP TESTER
    IEEE C57.100-2011 IEEE Standard Test Procedure for Thermal Evaluation of Insulation Systems for Liquid-Immersed Distribution and Power Transformers
    IEEE 1276-1997 IEEE Guide for the Application of High-Temperature Insulation Materials in Liquid-Immersed Power Transformers
    IEEE 1538-2000 IEEE Guide for Determination of Maximum Winding Temperature Rise in Liquid-Filled Transformers
    IEEE C57.12.10-2010 REDLINE IEEE Standard Requirements for Liquid-Immersed Power Transformers
    IEEE C57.147-2008 IEEE Guide for Acceptance and Maintenance of Natural Ester Fluids in Transformers
    IEEE C57.106-2006 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment
    IEEE C57.131-2012 IEEE Standard Requirements for Tap Changers
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications