1 Purpose
2 Scope
3 Definitions
4 General requirements
5 Construction
5.1 General
5.2 Meters, indicators, and outputs
5.3 Alarm/output function(s) (where provided)
5.4 Trouble signals
5.5 Controls and adjustments
5.6 Consumables
6 Instrument markings and instruction manuals
6.1 Markings on instruments
6.2 Instruction manual
7 Performance tests
7.1 General
7.2 Sequence of tests
7.3 Preparation of the instrument
7.4 Conditions for test and test area
7.5 Non-powered transportation
7.6 Drop test
7.7 Vibration
7.8 Initial calibration and set-up
7.9 Accuracy
7.10 Repeatability
7.11 Step change response and recovery
7,12 Supply voltage variation
7.13 Temperature variation
7.14 Humidity variation
7.15 Position sensitivity
7.16 Air velocity variation
7.17 Radio frequency interference (RFI)
7.18 Long-term stability
7.19 Battery and low-battery voltage alarm
7.20 Exposure to high concentration gas
Annex A (Informative) References
Annex B Applicability & Acceptance Criteria (Normative)
Specifies the details of construction, performance, and testing of portable, mobile, and stationary electrical gas-detection instruments operating at ambient temperatures and pressures used to provide a warning of the presence of toxic gases in air.
| Committee |
SP92
|
| DevelopmentNote |
Supersedes ISA S12.15 PT1 (07/1999) Formerly it was ISA S92.0.01-1. (05/2001)
|
| DocumentType |
Standard
|
| Pages |
40
|
| PublisherName |
International Society of Automation
|
| Status |
Withdrawn
|
| Supersedes |
| ANSI/ASSE Z390.1 : 2006 : R2010 | ACCEPTED PRACTICES FOR HYDROGEN SULFIDE (H[2]S) TRAINING PROGRAMS |
| I.S. EN ISO 10418:2003 | PETROLEUM AND NATURAL GAS INDUSTRIES - OFFSHORE PRODUCTION INSTALLATIONS - ANALYSIS, DESIGN, INSTALLATION AND TESTING OF BASIC SURFACE PROCESS SAFETY SYSTEMS |
| ANSI/ASSE Z390.1 : 2006 | ACCEPTED PRACTICES FOR HYDROGEN SULFIDE (H[2]S) TRAINING PROGRAMS |
| ISA 92.04.01-1 : 2007 | PERFORMANCE REQUIREMENTS FOR INSTRUMENTS USED TO DETECT OXYGEN-DEFICIENT/OXYGEN-ENRICHED ATMOSPHERES |
| ANSI/ASSE Z390.1 CHINESE : 2006 | ACCEPTED PRACTICES FOR HYDROGEN SULFIDE (H[2]S) TRAINING PROGRAMS |
| ANSI/ASSE Z390.1 : 2006 | ACCEPTED PRACTICES FOR HYDROGEN SULFIDE (H[2]S) TRAINING PROGRAMS |
| API 14F : 2008 : R2013 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| ANSI/ASSE Z390.1 SPANISH : 2006 | ACCEPTED PRACTICES FOR HYDROGEN SULFIDE (H[2]S) TRAINING PROGRAMS |
| API RP 14F:2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| ANSI/ASSE Z390.1 : 2006 : R2010 | ACCEPTED PRACTICES FOR HYDROGEN SULFIDE (H[2]S) TRAINING PROGRAMS |
| ABS 0063 : 2018 COR 2018 | RULES FOR BUILDING AND CLASSING FACILITIES ON OFFSHORE INSTALLATIONS |
| API 14F REDLINE : 2008 | DESIGN, INSTALLATION, AND MAINTENANCE OF ELECTRICAL SYSTEMS FOR FIXED AND FLOATING OFFSHORE PETROLEUM FACILITIES FOR UNCLASSIFIED AND CLASS 1, DIVISION 1 AND DIVISION 2 LOCATIONS |
| ISA RP92.06.02 : 1999 | INSTALLATION, OPERATION, AND MAINTENANCE OF CHLORINE DETECTION INSTRUMENTS (0.5-30 PPM FULL SCALE) |
| ISA RP92.03.02 : 1999 | INSTALLATION, OPERATION, AND MAINTENANCE OF AMMONIA DETECTION INSTRUMENTS (25-500 PPM - FULL SCALE) |
| CFR 46(PTS500-END) : OCT 2017 | SHIPPING - FEDERAL MARITIME COMMISSION |
| API RP 14C : 2017 | ANALYSIS, DESIGN, INSTALLATION, AND TESTING OF SAFETY SYSTEMS FOR OFFSHORE PRODUCTION FACILITIES |
| ISA S82.01 : 1994 | ELECTRICAL AND ELECTRONIC TEST, MEASURING, CONTROLLING AND RELATED EQUIPMENT - GENERAL REQUIREMENTS |
| ISA S12.1 : 1991 | DEFINITIONS AND INFORMATION PERTAINING TO ELECTRICAL INSTRUMENTS IN HAZARDOUS (CLASSIFIED) LOCATIONS |
| NFPA 496 : 2017 | PURGED AND PRESSURIZED ENCLOSURES FOR ELECTRICAL EQUIPMENT |
| CFR 46(PTS140-155) : OCT 2017 | SHIPPING - COAST GUARD, DEPARTMENT OF TRANSPORTATION |
| NACE MR 01 75 : 2003 | METALS FOR SULFIDE STRESS CRACKING AND STRESS CORROSION CRACKING RESISTANCE IN SOUR OILFIELD ENVIRONMENTS |
| IEEE 315 : 1975 | GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS) |
| IEEE 142 : 2007 | GROUNDING OF INDUSTRIAL AND COMMERCIAL POWER SYSTEMS |
| NFPA 70 : 2017 | NATIONAL ELECTRICAL CODE |
| CFR 29(PT1910.1000 TO END) : 0 | LABOR - OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR |
| ISA RP12.13.02 : 2003 | INSTALLATION, OPERATION, AND MAINTENANCE OF COMBUSTIBLE GAS DETECTION INSTRUMENTS |
| ISA S12.4 : 1970 | INSTRUMENT PURGING FOR REDUCTION OF HAZARDOUS AREA CLASSIFICATION |
| CFR 30(PTS200-699) : JUL 2017 | MINERAL RESOURCES - DEPARTMENT OF THE INTERIOR |
| IEC 60654-1:1993 | Industrial-process measurement and control equipment - Operating conditions - Part 1: Climatic conditions |
| FM 6310,20 : 2001 | COMBUSTIBLE GAS DETECTORS |