FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 General
5 Test bed and operations
6 General test conditions
7 Climatic tests
8 Mechanical tests
9 Markings and identification
10 User manual
11 Electromagnetic immunity
12 Electrical safety
13 Suitability of components
14 Simple circumvention
15 Explosive atmosphere
16 Field verification (process automation devices)
Annex A (informative) - Comparison of immunity levels in
        several IEC standards
Annex B (informative) - Product, sector and application
        specific requirements
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Gives information about the assessment aspects of safe communication such as test beds, proof of increased interference immunity (EMC for functional safety), electrical safety, and other environmental requirements.

Committee
GEL/65/3
DevelopmentNote
Renumbers & supersedes BS PD IEC TR 62685. 2011 version incorporates corrigendum to BS PD IEC TR 62685. (11/2011)
DocumentType
Standard
Pages
40
PublisherName
British Standards Institution
Status
Current

This Technical Report provides information about the assessment aspects of safe communication such as test beds, proof of increased interference immunity (EMC for functional safety), electrical safety, and other environmental requirements.

This document is only applicable to safety devices for functional safety communication which are developed according to IEC 61508 and IEC 61784-3.

NOTE This document does not cover the more complex aspects of preserving existing devices and applications in the field and migration from safety rules before IEC 61508.

The scope covers general industrial environments such as defined in IEC 61131-2 or IEC 61000-6-2 and process automation environments such as those covered in the IEC 61326 series.

Reference is made to the ERS (Equipment Requirements Specification) and/or SRS (Safety Requirements Specification) of a particular safety application to verify the necessary immunity of devices and systems according to IEC 61508.