Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Test method
6 Assessment and verification of constancy of
performance - AVCP
7 Marking, Labelling and packaging
Annex A (informative) - Product characteristics possibly
affected by change of components
Annex B (normative) - Extension of test results following
the size
Annex C (informative) - Example of performance and
requirement profile of an Internal pedestrian
doorsets without resistance to fire and/or smoke
leakage characteristics
Annex D (informative) - Examples for opening dimensions of
internal pedestrian doorsets without resistance to
fire and/or smoke leakage characteristics
Annex E (informative) - Handling, installation, maintenance
and care
Annex F (normative) - Selection, preparation mounting and
fixing of test specimen for reaction to fire tests
of pedestrian doorsets and field of direct application
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Regulation
Annex ZB (informative) - Relationship of this European
Standard and the Essential Requirements of
EU Directive 2006/42/EC
Annex ZC (informative) - Relationship of this European
Standard and the essential Requirements of
EU Directive 2004/108/EC
Bibliography
Specifies material independent performance characteristics that are applicable to internal pedestrian doorsets without resistance to fire and/or smoke leakage characteristics.
| Committee |
TC 33
|
| DocumentType |
Draft
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Current
|
| Standards | Relationship |
| 14/30297827 DC : 0 | Identical |
| NEN EN 14351-2 : DRAFT 2014 | Identical |
| 14/30297827 DC : DRAFT APR 2014 | Identical |
| 17/30347436 DC : 0 | BS EN 15269-1 - EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 1: GENERAL REQUIREMENTS |
| EN 12488:2016 | Glass in building - Glazing recommendations - Assembly principles for vertical and sloping glazing |
| DIN EN 16034:2014-12 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resistance and/or smoke control characteristics; German version EN 16034:2014 |
| BS EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows. Product standard, performance characteristics. Fire resisting and/or smoke control characteristics |
| I.S. EN 16034:2014 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND OPENABLE WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS |
| BS EN 16361 : 2013 | POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION |
| PREN 15269-1 : DRAFT 2017 | EXTENDED APPLICATION OF TEST RESULTS FOR FIRE RESISTANCE AND/OR SMOKE CONTROL FOR DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES, INCLUDING THEIR ELEMENTS OF BUILDING HARDWARE - PART 1: GENERAL REQUIREMENTS |
| I.S. EN 12488:2016 | GLASS IN BUILDING - GLAZING RECOMMENDATIONS - ASSEMBLY PRINCIPLES FOR VERTICAL AND SLOPING GLAZING |
| I.S. EN 16361:2013 | POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION |
| I.S. EN 14351-1:2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS |
| I.S. EN 14600:2005 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
| PREN 1125 : DRAFT 2016 | BUILD HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
| PREN 179 : DRAFT 2016 | BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
| PREN 16759 : DRAFT 2014 | STRUCTURAL SEALANT GLAZING SYSTEMS (SSGS) |
| BS EN 14600:2005 | Doorsets and openable windows with fire resisting and/ or smoke control characteristics. Requirements and classification |
| BS EN 12488:2016 | Glass in building. Glazing recommendations. Assembly principles for vertical and sloping glazing |
| 18/30367193 DC : 0 | BS EN 17213 - WINDOWS AND DOORS - ENVIRONMENTAL PRODUCT DECLARATIONS - PRODUCT CATEGORY RULES FOR WINDOWS AND PEDESTRIAN DOORSETS |
| 16/30343246 DC : 0 | BS EN 1125 - BUILDING HARDWARE - PANIC EXIT DEVICES OPERATED BY A HORIZONTAL BAR, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
| PREN 17146 : DRAFT 2017 | DETERMINATION OF THE STRENGTH OF INFILL SUPPORTS - TEST METHOD AND REQUIREMENTS |
| BS EN 14351-1 : 2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS |
| EN 16034:2014 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
| EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
| EN 14600:2005 | Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification |
| EN 16361:2013+A1:2016 | Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation |
| PD 6686:2006 | Guidance on directives, regulations and standards related to prevention of fire and explosion in the process industries |
| 11/30253413 DC : 0 | BS EN 16361 - POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOOR SETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION WITHOUT RESISTANCE TO FIRE AND SMOKE LEAKAGE CHARACTERISTICS |
| PREN 17213 : DRAFT 2018 | WINDOWS AND DOORS - ENVIRONMENTAL PRODUCT DECLARATIONS - PRODUCT CATEGORY RULES FOR WINDOWS AND PEDESTRIAN DOORSETS |
| 17/30360046 DC : 0 | BS EN 17146 - DETERMINATION OF THE STRENGTH OF INFILL SUPPORTS - TEST METHOD AND REQUIREMENTS |
| 16/30343249 DC : 0 | BS EN 179 - BUILDING HARDWARE - EMERGENCY EXIT DEVICES OPERATED BY A LEVER HANDLE OR PUSH PAD, FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
| 14/30300917 DC : 0 | BS EN 16759 - STRUCTURAL SEALANT GLAZING SYSTEMS (SSGS) |
| DIN EN 14600:2006-03 | DOORSETS AND OPENABLE WINDOWS WITH FIRE RESISTING AND/OR SMOKE CONTROL CHARACTERISTICS - REQUIREMENTS AND CLASSIFICATION |
| UNE-EN 14351-1:2006 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics |
| UNE-EN 16034:2015 | Pedestrian doorsets, industrial, commercial, garage doors and openable windows - Product standard, performance characteristics - Fire resisting and/or smoke control characteristics |
| UNE-EN 16361:2014 | Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation without resistance to fire and smoke leakage characteristics |
| EN 950:1999 | Door leaves - Determination of the resistance to hard body impact |
| EN 16361:2013+A1:2016 | Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation |
| EN 13124-2:2004 | Windows, doors and shutters - Explosion resistance - Test method - Part 2: Range test |
| EN 1125:2008 | Building hardware - Panic exit devices operated by a horizontal bar, for use on escape routes - Requirements and test methods |
| ISO 10140-2:2010 | Acoustics — Laboratory measurement of sound insulation of building elements — Part 2: Measurement of airborne sound insulation |
| EN 13123-2:2004 | Windows, doors, and shutters - Explosion resistance - Requirements and classification - Part 2: Range test |
| EN 1523:1998 | Windows, doors, shutters and blinds - Bullet resistance - Test method |
| EN 12365-2:2003 | Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 2: Linear compression force test methods |
| EN 1627:2011 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification |
| EN 12400:2002 | Windows and pedestrian doors - Mechanical durability - Requirements and classification |
| ISO 10140-1:2016 | Acoustics — Laboratory measurement of sound insulation of building elements — Part 1: Application rules for specific products |
| 2004/108/EC : 2004 | DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 DECEMBER 2004 ON THE APPROXIMATION OF THE LAWS OF THE MEMBER STATES RELATING TO ELECTROMAGNETIC COMPATIBILITY AND REPEALING DIRECTIVE 89/336/EC |
| ISO 140-3:1995 | Acoustics — Measurement of sound insulation in buildings and of building elements — Part 3: Laboratory measurements of airborne sound insulation of building elements |
| EN ISO 10140-1:2016 | Acoustics - Laboratory measurement of sound insulation of building elements - Part 1: Application rules for specific products (ISO 10140-1:2016) |
| ISO 10077-2:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 2: Numerical method for frames |
| EN 12207:2016 | Windows and doors - Air permeability - Classification |
| EN 14179-2:2005 | Glass in building - Heat soaked thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
| PREN 16034 : DRAFT 2009 | PEDESTRIAN DOORSETS, INDUSTRIAL, COMMERCIAL, GARAGE DOORS AND WINDOWS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - FIRE RESISTANCE AND/OR SMOKE CONTROL CHARACTERISTICS |
| EN 951:1998 | Door leaves - Method for measurement of height, width, thickness and squareness |
| EN 12365-1:2003 | Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 1: Performance requirements and classification |
| EN 948:1999 | Hinged or pivoted doors - Determination of the resistance to static torsion |
| EN 12519:2004 | Windows and pedestrian doors - Terminology |
| EN ISO 10077-2:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO 10077-2:2017) |
| EN 1192:1999 | Doors - Classification of strength requirements |
| EN 1294:2000 | Door leaves - Determination of the behaviour under humidity variations in successive uniform climates |
| EN 1121:2000 | Doors - Behaviour between two different climates - Test method |
| EN 13123-1:2001 | Windows, doors and shutters - Explosion resistance - Requirements and classification - Part 1: Shock tube |
| ISO 12567-1:2010 | Thermal performance of windows and doors — Determination of thermal transmittance by the hot-box method — Part 1: Complete windows and doors |
| EN 12365-3:2003 | Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 3: Deflection recovery test method |
| EN 12046-2:2000 | Operating forces - Test method - Part 2: Doors |
| EN 947:1998 | Hinged or pivoted doors - Determination of the resistance to vertical load |
| PREN 13637 : DRAFT 2014 | BUILDING HARDWARE - ELECTRICALLY CONTROLLED EXIT SYSTEMS FOR USE ON ESCAPE ROUTES - REQUIREMENTS AND TEST METHODS |
| EN 12150-2:2004 | Glass in building - Thermally toughened soda lime silicate safety glass - Part 2: Evaluation of conformity/Product standard |
| PREN 1026 : DRAFT 2013 | WINDOWS AND DOORS - AIR PERMEABILITY - TEST METHOD |
| EN 13241-1:2003+A1:2011 | Industrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics |
| EN 13124-1:2001 | Windows, doors and shutters - Explosion resistance - Test method - Part 1: Shock tube |
| EN 12365-4:2003 | Building hardware - Gasket and weatherstripping for doors, windows, shutters and curtain walling - Part 4: Recovery after accelerated ageing test method |
| EN 1629:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading |
| EN ISO 10140-2:2010 | Acoustics - Laboratory measurement of sound insulation of building elements - Part 2: Measurement of airborne sound insulation (ISO 10140-2:2010) |
| EN 13049:2003 | Windows - Soft and heavy body impact - Test method, safety requirements and classification |
| EN 12354-3:2000 | Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Part 3: Airborne sound insulation against outdoor sound |
| EN 12217:2015 | Doors - Operating forces - Requirements and classification |
| EN 12219:1999 | Doors - Climatic influences - Requirements and classification |
| EN 1630:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts |
| ISO 717-1:2013 | Acoustics — Rating of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation |
| EN 1522:1998 | Windows, doors, shutters and blinds - Bullet resistance - Requirements and classification |
| EN 949:1998 | Windows and curtain walling, doors, blinds and shutters - Determination of the resistance to soft and heavy body impact for doors |
| EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
| ISO 10077-1:2017 | Thermal performance of windows, doors and shutters — Calculation of thermal transmittance — Part 1: General |
| EN 1191:2012 | Windows and doors - Resistance to repeated opening and closing - Test method |
| EN 1628:2011+A1:2015 | Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading |
| EN 12600:2002 | Glass in building - Pendulum test - Impact test method and classification for flat glass |
| EN ISO 10077-1:2017 | Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2017, Corrected version 2020-02) |
| EN 179:2008 | Building hardware - Emergency exit devices operated by a lever handle or push pad, for use on escape routes - Requirements and test methods |