UNE-EN 60079-2:2015
Current
The latest, up-to-date edition.
Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
Hardcopy , PDF
Spanish, Castilian, English
30-09-2015
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Protection types
5 Constructional requirements for pressurized enclosures
5.1 Enclosure
5.2 Materials
5.3 Doors and covers
5.4 Mechanical strength
5.5 Apertures, partitions, compartments and internal
components
5.6 Insulating materials
5.7 Sealing
5.8 Spark and particle barriers
6 Temperature limits
6.1 General
6.2 For type px or type py
6.3 For type pz
7 Safety provisions and safety devices (except for
static pressurization)
8 Safety provisions and safety devices for static
pressurization
9 Supply of protective gas
9.1 Type of gas
9.2 Temperature
10 Pressurized apparatus with an internal source of
release
11 Release conditions
11.1 No release
11.2 Limited release of a gas or vapour
11.3 Limited release of a liquid
12 Design requirements for the containment system
12.1 General design requirements
12.2 Infallible containment system
12.3 Containment system with a limited release
13 Protective gas and pressurizing techniques
13.1 General
13.2 Pressurization with leakage compensation
13.3 Pressurization with dilution
14 Ignition-capable apparatus
15 Internal hot surfaces
16 Type verification and tests
16.1 Maximum overpressure test
16.2 Leakage test
16.3 Purging test for pressurized enclosures with no
internal source of release (pressurization
technique may be leakage compensation or
continuous flow) and filling procedure test for
static pressurization
16.4 Purging and dilution tests for a pressurized
enclosure with an internal source of release
16.5 Verification of minimum overpressure
16.6 Tests for an infallible containment system
16.7 Overpressure test for a containment system with a
limited release
16.8 Verifying ability of the pressurized enclosure to
limit internal pressure
17 Routine tests
17.1 Functional test
17.2 Leakage test
17.3 Tests for an infallible containment system
17.4 Test for a containment system with a limited release
18 Marking
Annex A (normative) Purging and dilution tests
Annex B (informative) Examples of functional sequence diagram
Annex C (informative) Examples of the changes in pressure in
ducts and enclosures
Annex D (informative) Information to be provided to the user
Annex E (normative) Classification of the type of release
within enclosures
Annex F (informative) Examples for the use of the dilution area
concept
Annex G (normative) Infallibility test for containment system
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Figures
Tables
Contains the specific requirements for the construction and testing of electrical apparatus with pressurized enclosures, of protection type 'p', intended for use in explosive gas atmospheres.
Committee |
CTN 202/SC 31
|
DevelopmentNote |
Supersedes UNE EN 50016. (06/2007) Supersedes UNE 20319. (04/2010) Supersedes UNE EN 61241-4. (09/2017)
|
DocumentType |
Standard
|
Pages |
92
|
PublisherName |
Asociacion Espanola de Normalizacion
|
Status |
Current
|
Supersedes |
Standards | Relationship |
BS EN 60079-2:2014 | Identical |
NF EN 60079-2 : 2015 | Identical |
NBN EN 60079-2 : 2015 COR 2015 | Identical |
I.S. EN 60079-2:2014 | Identical |
SN EN 60079-2 : 2014 COR 2016 | Identical |
DIN EN 60079-2 : 2015 COR 1 2016 | Identical |
EN 60079-2:2014/AC:2015 | Identical |
IEC 60079-2:2014/COR1:2015 | Identical |
IEC 60079-2:2014 | Identical |
EN 60079-2:2014 | Identical |
UNE 60631-1:2014 | Compressed natural gas filling stations. Part 1: Stations with supply capacity above 20 m3/h. |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60079-1:2014 RLV | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 60079-26:2015 | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
EN 60079-1:2014 | Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" |
EN 60079-0:2012/A11:2013 | EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED) |
EN 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60079-18:2014 RLV | Explosive atmospheres - Part 18: Equipment protection by encapsulation “m” |
IEC 60079-20-1:2010 | Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
EN 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
EN 60079-28:2015 | Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation |
IEC 60079-5:2015 RLV | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
IEC 60050-426:2008 | International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
EN 60079-11:2012 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60079-11:2011 | Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
EN 60079-20-1:2010 | Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
EN 60079-5:2015 | Explosive atmospheres - Part 5: Equipment protection by powder filling "q" |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60079-13:2017 | Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" |
IEC 60079-15:2010 | Explosive atmospheres - Part 15: Equipment protection by type of protection "n" |
IEC 60079-13:2017 | Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" |
IEC 60079-26:2014 RLV | Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga |
EN 60034-5:2001/A1:2007 | ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE) - CLASSIFICATION |