UNE-EN 60079-2:2015

Current

Current

The latest, up-to-date edition.

Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"

Available format(s)

Hardcopy , PDF

Language(s)

Spanish, Castilian, English

Published date

30-09-2015

€152.40
Excluding VAT

Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Protection types
5 Constructional requirements for pressurized enclosures
   5.1 Enclosure
   5.2 Materials
   5.3 Doors and covers
   5.4 Mechanical strength
   5.5 Apertures, partitions, compartments and internal
       components
   5.6 Insulating materials
   5.7 Sealing
   5.8 Spark and particle barriers
6 Temperature limits
   6.1 General
   6.2 For type px or type py
   6.3 For type pz
7 Safety provisions and safety devices (except for
   static pressurization)
8 Safety provisions and safety devices for static
   pressurization
9 Supply of protective gas
   9.1 Type of gas
   9.2 Temperature
10 Pressurized apparatus with an internal source of
   release
11 Release conditions
   11.1 No release
   11.2 Limited release of a gas or vapour
   11.3 Limited release of a liquid
12 Design requirements for the containment system
   12.1 General design requirements
   12.2 Infallible containment system
   12.3 Containment system with a limited release
13 Protective gas and pressurizing techniques
   13.1 General
   13.2 Pressurization with leakage compensation
   13.3 Pressurization with dilution
14 Ignition-capable apparatus
15 Internal hot surfaces
16 Type verification and tests
   16.1 Maximum overpressure test
   16.2 Leakage test
   16.3 Purging test for pressurized enclosures with no
        internal source of release (pressurization
        technique may be leakage compensation or
        continuous flow) and filling procedure test for
        static pressurization
   16.4 Purging and dilution tests for a pressurized
        enclosure with an internal source of release
   16.5 Verification of minimum overpressure
   16.6 Tests for an infallible containment system
   16.7 Overpressure test for a containment system with a
        limited release
   16.8 Verifying ability of the pressurized enclosure to
        limit internal pressure
17 Routine tests
   17.1 Functional test
   17.2 Leakage test
   17.3 Tests for an infallible containment system
   17.4 Test for a containment system with a limited release
18 Marking
Annex A (normative) Purging and dilution tests
Annex B (informative) Examples of functional sequence diagram
Annex C (informative) Examples of the changes in pressure in
                      ducts and enclosures
Annex D (informative) Information to be provided to the user
Annex E (normative) Classification of the type of release
                      within enclosures
Annex F (informative) Examples for the use of the dilution area
                      concept
Annex G (normative) Infallibility test for containment system
Annex ZA (normative) Normative references to international
                      publications with their corresponding
                      European publications
Bibliography
Figures
Tables

Contains the specific requirements for the construction and testing of electrical apparatus with pressurized enclosures, of protection type 'p', intended for use in explosive gas atmospheres.

Committee
CTN 202/SC 31
DevelopmentNote
Supersedes UNE EN 50016. (06/2007) Supersedes UNE 20319. (04/2010) Supersedes UNE EN 61241-4. (09/2017)
DocumentType
Standard
Pages
92
PublisherName
Asociacion Espanola de Normalizacion
Status
Current
Supersedes

UNE 60631-1:2014 Compressed natural gas filling stations. Part 1: Stations with supply capacity above 20 m3/h.

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
EN 60079-26:2015 Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
EN 60079-1:2014 Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
EN 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
IEC 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
EN 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
EN 60079-28:2015 Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
EN 60112 : 2003 AMD 1 2009 METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS
EN 60079-11:2012 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
EN 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
EN 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
EN 60079-5:2015 Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60079-13:2017 Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
IEC 60079-26:2014 RLV Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
EN 60034-5:2001/A1:2007 ROTATING ELECTRICAL MACHINES - PART 5: DEGREES OF PROTECTION PROVIDED BY THE INTEGRAL DESIGN OF ROTATING ELECTRICAL MACHINES (IP CODE) - CLASSIFICATION

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.