Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
   3.1 Anti-pollution check valves
   3.2 Flanged anti-pollution check valves; class a and
         class b
   3.3 Combined product
4 Nominal size
5 Designation
6 Marking and technical documents
   6.1 Marking
   6.2 Technical documents
7 Symbolization
8 General design characteristics
   8.1 Overall length and diameters of check valves
   8.2 End connections
   8.3 Test and drain ports
   8.4 Other characteristics
9 Physio-chemical characteristics
   9.1 Materials
   9.2 Nature of materials
10 Test Arrangements
   10.1 Sequence of testing
   10.2 Apparatus
11 Hydraulic and mechanical characteristics
   11.1 High velocity (stage 1)
   11.2 Flow rate/pressure loss (stage 2)
   11.3 Mechanical strength of the body (stage 3)
   11.4 Bending moment (stage 4)
   11.5 Pressure tightness under a low reverse pressure
         differential (stage 5)
   11.6 Pressure tightness under a high reverse pressure
         and verification that the check valve has not
         jammed (stage 6)
   11.7 Pressure differential at which the check valve
         closes (stage 7)
   11.8 Compatibility with products used for disinfection
         of networks (stage 8)
   11.9 Endurance (stage 9)
   11.10 Pressure tightness under a low reverse pressure
         differential (stage 10)
   11.11 Pressure tightness under a high reverse pressure
         and verification that the check valve has not
         jammed (stage 11)
   11.12 Pressure differential at which the check valve
         closes (stage 12)
12 General working characteristics
   12.1 Resistance to corrosion
   12.2 Acoustic characteristics
13 Presentation at delivery
Annex A (informative) Numbers of test devices/tests

Describes the characteristics of anti-pollution check valves of DN 6 up to and including DN 250 that are suitable for use in drinking water systems.

Committee
B/504
DevelopmentNote
Supersedes 00/107336 DC. (10/2006) Supersedes BS 6282-1(1982). (11/2008)
DocumentType
Standard
Pages
34
PublisherName
British Standards Institution
Status
Current
Supersedes

The purpose of this document is to specify: field of application of anti-pollution check valves; backflow prevention properties, dimensional and physio-chemical properties, and properties of general hydraulic, mechanical and acoustic design for anti-pollution check valves of nominal sizes DN 6 to DN 250 inclusive; family E, type A, controllable anti-pollution check valve (with test port); family E, type B, non-controllable anti-pollution check valve, including cartridge check valve; family E, type C, controllable anti-pollution double check valve (with test ports); family E, type D, non-controllable anti-pollution double check valve, including cartridge double check valve; test procedures and requirements for verifying the backflow protection properties of smiddle valves, draw-off taps etc. which incorporate a check valve function. Smiddle valves, draw off taps etc, need also to comply with a recognised standard; marking; presentation at delivery. This document specifies the characteristics of anti-pollution check valves of DN 6 up to and including DN 250 that are suitable for use in drinking water systems. For application feasibility see Table 1. Table 1 — Nominal size vs Conditions of use Nominal size (DN) Max. Operating temperature Max. Operating pressure Installation DN ≤ 50 65 °C + 90 °C, 1 h 1 000 kPa (10 bar) Any position DN > 50 65 °C 1 000 kPa (10 bar) Horizontal only Anti-pollution check valves covered by this document are of pressure class PN 10. In case of devises with pressure class PN 16, the anti–pollution check valves has to comply with the tests which characterise the PN of the devise. The field of application of EN 1717 is limited to 10 bar, flanges could be drilled in PN 16 pattern.

Standards Relationship
UNI EN 13959 : 2005 Identical
NS EN 13959 : 1ED 2005 Identical
EN 13959:2004 Identical
NF EN 13959 : 2005 Identical
NEN EN 13959 : 2004 Identical
I.S. EN 13959:2004 Identical
SN EN 13959 : 2004 Identical
UNE-EN 13959:2005 Identical
NBN EN 13959 : 2004 Identical
DIN EN 13959:2005-01 Identical

17/30351608 DC : 0 BS 5410-2 - CODE OF PRACTICE FOR OIL FIRING - PART 2: INSTALLATIONS PROVIDING SPACE HEATING, HOT WATER AND STEAM SUPPLY SERVICES TO NON-DOMESTIC BUILDINGS
11/30228295 DC : 0 BS 8558 - GUIDE TO THE DESIGN, INSTALLATION, TESTING, OPERATION AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - COMPLEMENTARY GUIDANCE TO BS EN 806
BS 8558:2015 Guide to the design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages. Complementary guidance to BS EN 806
12/30170835 DC : 0 BS 5410-2 - CODE OF PRACTICE FOR OIL FIRING - PART 2: SPACE HEATING, HOT WATER AND STEAM SUPPLY SERVICES FOR COMMERCIAL AND INDUSTRIAL PREMISES
11/30229801 DC : 0 BS 6644 - SPECIFICATION FOR THE INSTALLATION OF GAS-FIRED HOT WATER BOILERS OF RATED INPUTS BETWEEN 70 KW (NET) AND 1.8 MW (NET) (2ND AND 3RD FAMILY GASES)
BS 6644:2011 Specification for the installation and maintenance of gas-fired hot water boilers of rated inputs between 70 kW (net) and 1.8 MW (net) (2nd and 3rd family gases)
16/30329500 DC : 0 BS 5834-1 - SURFACE BOXES, GUARDS AND UNDERGROUND CHAMBERS FOR THE PURPOSES OFUTILITIES - PART 1: SPECIFICATION FOR GUARDS AND PLINTHS
BS 8558:2011 Guide to the design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages. Complementary guidance to BS EN 806
15/30299694 DC : 0 BS 8558 - GUIDE TO THE DESIGN, INSTALLATION, TESTING AND MAINTENANCE OF SERVICES SUPPLYING WATER FOR DOMESTIC USE WITHIN BUILDINGS AND THEIR CURTILAGES - COMPLEMENTARY GUIDANCE TO BS EN 806
BS 5410-2:2013 Code of practice for oil firing Installations over 45 kW output capacity for space heating, hot water and steam supply services
BS 5834-1:2017 Surface boxes, guards and underground chambers for the purposes of utilities Specification for guards and plinths

ISO 3822-1:1999 Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 1: Method of measurement
ISO 5167-3:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 3: Nozzles and Venturi nozzles
EN 1254-3:1998 Copper and copper alloys - Plumbing fittings - Part 3: Fittings with compression ends for use with plastics pipes
EN 1254-1:1998 Copper and copper alloys - Plumbing fittings - Part 1: Fittings with ends for capillary soldering or capillary brazing to copper tubes
EN 1254-2:1998 Copper and copper alloys - Plumbing fittings - Part 2: Fittings with compression ends for use with copper tubes
EN 558-1 : 1995 INDUSTRIAL VALVES - FACE-TO-FACE AND CENTRE-TO-FACE DIMENSIONS OF METAL VALVES FOR USE IN FLANGED PIPE SYSTEMS - PN-DESIGNATED VALVES
EN 1717:2000 Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow
EN ISO 5167-3:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 3: Nozzles and Venturi nozzles (ISO 5167-3:2003)
ISO 6509:1981 Corrosion of metals and alloys Determination of dezincification resistance of brass
ISO 9227:2017 Corrosion tests in artificial atmospheres — Salt spray tests
ISO 3822-3:1997 Acoustics Laboratory tests on noise emission from appliances and equipment used in water supply installations Part 3: Mounting and operating conditions for in-line valves and appliances
EN ISO 6509:1995 Corrosion of metals and alloys - Determination of dezincification resistance of brass (ISO 6509:1981)
EN 1092-2:1997 Flanges and their joints - Circular flanges for pipes, valves, fittings and accessories, PN designated - Part 2: Cast iron flanges
EN 1267:2012 Industrial valves - Test of flow resistance using water as test fluid