BS EN 60310:2016
Current
The latest, up-to-date edition.
Railway applications. Traction transformers and inductors on board rolling stock
Hardcopy , PDF
English
30-04-2018
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Classification
5 Service conditions
6 Rated current and load profile
7 Rated voltage and power of transformer windings
8 Transformer tappings
9 Cooling
10 Temperature limits
11 Mechanical design
12 Rating plates
13 Tests
Annex A (informative) - List of items for which an
agreement between purchaser and manufacturer
is needed or for which further information or
specifications shall be given by the purchaser or
by the manufacturer
Annex B (informative) - Thermal ageing and insulation
life time
Annex C (informative) - Example of thermal endurance
calculation to demonstrate the suitability of an
insulation system for a specified application
Annex D (informative) - Wet dielectric tests for dry-type
transformers and inductors
Annex E (informative) - Load profiles
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Pertains to traction and auxiliary power transformers installed on board rolling stock and to the various types of power inductors inserted in the traction and auxiliary circuits of rolling stock of dry or liquid-immersed design.
Committee |
GEL/9
|
DevelopmentNote |
Supersedes 93/208795 DC, BS 7565(1992) and 00/242683 DC. (05/2004) Supersedes 14/30271248 DC. (05/2016)
|
DocumentType |
Standard
|
Pages |
76
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
This International Standard applies to traction and auxiliary power transformers installed on board rolling stock and to the various types of power inductors inserted in the traction and auxiliary circuits of rolling stock, of dry or liquid-immersed design.
NOTE The requirements of IEC60076(allparts) are applicable to transformers and inductors where they do not conflict with this standard, or with the specialized IEC publications dealing with traction applications.
This standard can also be applied, after agreement between purchaser and manufacturer, to the traction transformers of three-phase a.c. line-side powered vehicles and to the transformers inserted in the single-phase or poly-phase auxiliary circuits of vehicles, except instrument transformers and transformers of a rated output below 1 kVA single-phase or 5 kVA poly-phase.
This standard does not cover accessories such as tap changers, resistors, heat exchangers, fans, etc., intended for mounting on the transformers or inductors, which are tested separately according to relevant rules.
Standards | Relationship |
IEC 60310:2016 | Identical |
IEC 60310:2016/COR1:2018 | Identical |
EN 60310:2016/AC:2018-03 | Identical |
NF EN 60310 : 2017 | Identical |
NBN EN 60310 : 2016 | Identical |
I.S. EN 60310:2016 | Identical |
SN EN 60310 : 2016 | Identical |
UNE-EN 60310:2017 | Identical |
EN 60310:2016 | Equivalent |
DIN EN 60310 : 2017 COR 1 2018 | Identical |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
IEC 61287-1:2014 | Railway applications - Power converters installed on board rolling stock - Part 1: Characteristics and test methods |
EN 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
EN 60076-4:2002 | Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
ISO 9614-1:1993 | Acoustics — Determination of sound power levels of noise sources using sound intensity — Part 1: Measurement at discrete points |
IEC 61039:2008 | Classification of insulating liquids |
EN 61373:2010/AC:2017-09 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010) |
EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
EN 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60076-18:2012 | Power transformers - Part 18: Measurement of frequency response |
EN 60076-11:2004 | Power transformers - Part 11: Dry-type transformers |
EN 61099:2010 | Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
IEC 60076-14:2013 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
ISO 9614-2:1996 | Acoustics — Determination of sound power levels of noise sources using sound intensity — Part 2: Measurement by scanning |
EN 61039 : 2008 | CLASSIFICATION OF INSULATING LIQUIDS |
IEC 60850:2014 | Railway applications - Supply voltages of traction systems |
IEC 61099:2010 | Insulating liquids - Specifications for unused synthetic organic esters for electrical purposes |
EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
IEC 60076-4:1976 | Power transformers - Part 4: Tappings and connections |
IEC 60505:2011 | Evaluation and qualification of electrical insulation systems |
IEC 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60076-12:2008 | Power transformers - Part 12: Loading guide for dry-type power transformers |
EN 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN 60060-2:2011 | High-voltage test techniques - Part 2: Measuring systems |
ISO 3746:2010 | Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Survey method using an enveloping measurement surface over a reflecting plane |
IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
EN ISO 3746:2010 | Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane (ISO 3746:2010) |
EN 60296:2012 | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
EN 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
IEC 60076-1:2011 | Power transformers - Part 1: General |
IEC 60076-6:2007 | Power transformers - Part 6: Reactors |
EN 60216-5:2008 | Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material |
EN 60076-14:2013 | Power transformers - Part 14: Liquid-immersed power transformers using high-temperature insulation materials |
EN 60076-1:2011 | POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011) |
EN ISO 9614-2:1996 | Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 2: Measurement by scanning (ISO 9614-2:1996) |
IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 62497-1:2010+AMD1:2013 CSV | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electricaland electronic equipment |
EN 60076-18 : 2012 | POWER TRANSFORMERS - PART 18: MEASUREMENT OF FREQUENCY RESPONSE (IEC 60076-18:2012) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60216-5:2008 | Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material |
EN 61378-1:2011 | Convertor transformers - Part 1: Transformers for industrial applications |
EN 60505:2011/AC:2017-03 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS (IEC 60505:2011/COR1:2017) |
IEC 60077-1:2017 | Railway applications - Electric equipment for rolling stock - Part 1: General service conditions and general rules |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
EN 61287-1:2014/AC:2014 | RAILWAY APPLICATIONS - POWER CONVERTERS INSTALLED ON BOARD ROLLING STOCK - PART 1: CHARACTERISTICS AND TEST METHODS (IEC 61287-1:2014) |
EN ISO 9614-1:2009 | Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 1: Measurement at discrete points (ISO 9614-1:1993) |
IEC 60216-1:2013 | Electrical insulating materials - Thermal endurance properties - Part 1: Ageing procedures and evaluation of test results |
IEC 61378-1:2011 | Converter transformers - Part 1: Transformers for industrial applications |
IEC 62498-1:2010 | Railway applications - Environmental conditions for equipment - Part 1: Equipment on board rolling stock |
EN 60076-6:2008 | Power transformers - Part 6: Reactors |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.