• Shopping Cart
    There are no items in your cart

CAN/CSA-C50-14 (R2018)

Current

Current

The latest, up-to-date edition.

Mineral insulating oil, electrical, for transformers and switches

Available format(s)

Hardcopy , PDF

Language(s)

English, French

Published date

01-01-2014

€107.68
Excluding VAT

Preface
1 Scope
2 Reference publications
3 Definitions
4 General requirements
5 Sampling
6 Properties
7 Delivery

Preface This is the seventh edition of CSA C50, Mineral insulating oil electrical for transformers and switches. It supersedes the 2008 edition of the same title and the 1997, 1976, 1965, 1958, and 1938 editions, which were titled Insulating oil electrical for transformers and switches. The changes introduced in this edition are the following: a) Requirements for the detection of potentially corrosive sulphur have been added; b) Requirements for the detection of dibenzyldisulphide (DBDS) have been added; c) Requirements for the detection of metal passivators in oxidation inhibitors have been added; and d) Requirements concerning additives in oil have been added. It needs to be recognized that the tests specified in this Standard do not indicate the relative service lives of different oils. Purchasers should use these tests to determine the characteristics of oils that have been found by experience to be satisfactory and to detect any significant variations in the characteristics of further shipments of such oils. Scope 1.1 This Standard specifies the requirements for mineral oil of petroleum origin for use in transformers, oil circuit breakers, or other electrical equipment (excluding high-voltage cables) requiring a liquid insulating and cooling medium. 1.2 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised by not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

DevelopmentNote
French Edition issued on 01-08-2014. (08/2014)
DocumentType
Standard
ISBN
978-1-77139-567-0
Pages
0
PublisherName
Canadian Standards Association
Status
Current
Supersedes

Preface This is the seventh edition of CSA C50, Mineral insulating oil electrical for transformers and switches. It supersedes the 2008 edition of the same title and the 1997, 1976, 1965, 1958, and 1938 editions, which were titled Insulating oil electrical for transformers and switches. The changes introduced in this edition are the following: a) Requirements for the detection of potentially corrosive sulphur have been added; b) Requirements for the detection of dibenzyldisulphide (DBDS) have been added; c) Requirements for the detection of metal passivators in oxidation inhibitors have been added; and d) Requirements concerning additives in oil have been added. It needs to be recognized that the tests specified in this Standard do not indicate the relative service lives of different oils. Purchasers should use these tests to determine the characteristics of oils that have been found by experience to be satisfactory and to detect any significant variations in the characteristics of further shipments of such oils. Scope 1.1 This Standard specifies the requirements for mineral oil of petroleum origin for use in transformers, oil circuit breakers, or other electrical equipment (excluding high-voltage cables) requiring a liquid insulating and cooling medium. 1.2 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised by not required; and \"may\" is used to express an option or that which is permissible within the limits of the standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

CSA C60044-5:2007 INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS
CSA C60044-5 : 2007 : R2011 INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS
CSA C2 : 0 SINGLE-PHASE AND THREE-PHASE DISTRIBUTION TRANSFORMERS, TYPES ONAN AND LNAN
CSA C227.3 : 2006 LOW-PROFILE, SINGLE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS
CSA C22.3 No. 61936-1 : 2008 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
CSA C22.3 No. 61936-1 : 2008 : R2015 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
CSA C227.4 : 2006 THREE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS
CSA C2.2:2006 : R2011 POLE-MOUNTED, SINGLE-PHASE DISTRIBUTION TRANSFORMERS FOR ELECTRIC UTILITIES
CSA C2.1 : 2006 SINGLE-PHASE AND THREE-PHASE LIQUID-FILLED DISTRIBUTION TRANSFORMERS
CSA C60044-2 : 2007 INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS
CSA C60044-2 : 2007 : R2011 INSTRUMENT TRANSFORMERS - PART 2: INDUCTIVE VOLTAGE TRANSFORMERS
CSA C61869-1 : 2014 INSTRUMENT TRANSFORMERS - PART 1: GENERAL REQUIREMENTS
CSA C22.2 No. 107.1 : 2016 POWER CONVERSION EQUIPMENT
CAN/CSA-C227.3-06 (R2017) Low-profile, single-phase, pad-mounted distribution transformers with separable insulated high-voltage connectors
CSA C227.4 : 2006 : R2017 THREE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS
CSA C227.5 : 2008 : R2013 THREE-PHASE LIVE-FRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS
CSA C227.3 : 2006 : R2011 LOW-PROFILE, SINGLE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS
CSA C2.1 : 2006 : R2011 SINGLE-PHASE AND THREE-PHASE LIQUID-FILLED DISTRIBUTION TRANSFORMERS
CSA C2.2 : 2006 POLE-MOUNTED, SINGLE-PHASE DISTRIBUTION TRANSFORMERS FOR ELECTRIC UTILITIES
CSA C227.5:2008 THREE-PHASE LIVE-FRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS
CSA C227.4 : 2006 : R2011 THREE-PHASE, PAD-MOUNTED DISTRIBUTION TRANSFORMERS WITH SEPARABLE INSULATED HIGH-VOLTAGE CONNECTORS
C88-16 Power transformers and reactors

IEC 61125:1992 Unused hydrocarbon based insulating liquids - Test methods for evaluating the oxidation stability
ASTM D 1816 : 2012 : REDLINE Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using VDE Electrodes
ASTM D 924 : 2015 : REDLINE Standard Test Method for Dissipation Factor (or Power Factor) and Relative Permittivity (Dielectric Constant) of Electrical Insulating Liquids
IEC 62535:2008 Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil
IEC 60475:2011 Method of sampling insulating liquids
IEC 61868:1998 Mineral insulating oils - Determination of kinematic viscosity at very low temperatures
ASTM D 1275 : 2015 Standard Test Method for Corrosive Sulfur in Electrical Insulating Liquids
ASTM D 1533 : 2012 : REDLINE Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration
ASTM D 2440 : 2013 : REDLINE Standard Test Method for Oxidation Stability of Mineral Insulating Oil
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
ASTM D 341 : 2017 : REDLINE Standard Practice for Viscosity-Temperature Charts for Liquid Petroleum Products
IEC 62697-1:2012 Test methods for quantitative determination of corrosive sulfur compounds in unused and used insulating liquids - Part 1: Test method for quantitative determination of dibenzyldisulfide (DBDS)
IEC 60666:2010 Detection and determination of specified additives in mineral insulating oils
ASTM D 5837 : 2015 : REDLINE Standard Test Method for Furanic Compounds in Electrical Insulating Liquids by High-Performance Liquid Chromatography (HPLC)
ASTM D 923 : 2015 : REDLINE Standard Practices for Sampling Electrical Insulating Liquids
ASTM D 2112 : 2015 : REDLINE Standard Test Method for Oxidation Stability of Inhibited Mineral Insulating Oil by Pressure Vessel
ASTM D 877/D877M : 2013 : REDLINE Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes
ASTM D 3300 : 2012 : REDLINE Standard Test Method for Dielectric Breakdown Voltage of Insulating Oils of Petroleum Origin Under Impulse Conditions

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.