1 General
   1.1 Scope
   1.2 Normative references
2 Definitions
   2.1 General definitions
   2.2 Additional definitions for measuring current
        transformers
   2.3 Additional definitions for protective current
        transformers
3 Normal and special service conditions
   3.1 Normal service conditions
   3.2 Special service conditions
   3.3 System earthing
4 Ratings
   4.1 Standard values of rated primary currents
   4.2 Standard values of rated secondary currents
   4.3 Rated continuous thermal current
   4.4 Standard values of rated output
   4.5 Short-time current ratings
   4.6 Limits of temperature rise
5 Design requirements
   5.1 Insulation requirements
   5.2 Mechanical requirements
6 Classification of tests
   6.1 Type tests
   6.2 Routine tests
   6.3 Special tests
7 Type tests
   7.1 Short-time current tests
   7.2 Temperature-rise test
   7.3 Impulse tests on primary winding
   7.4 Wet test for outdoor type transformers
   7.5 Radio interference voltage measurement
8 Routine tests
   8.1 Verification of terminal markings
   8.2 Power-frequency withstand tests on primary
        windings and partial discharge measurement
   8.3 Power-frequency withstand tests between sections
        of primary and secondary windings and on secondary
        windings
   8.4 Inter-turn overvoltage test
9 Special tests
   9.1 Chopped impulse test on primary winding
   9.2 Measurement of capacitance and dielectric
        dissipation factor
   9.3 Mechanical tests
   9.4 Transmitted overvoltages measurement
10 Markings
   10.1 Terminal markings - General rules
   10.2 Rating plate markings
11 Additional requirements for measuring current
   transformers
   11.1 Accuracy class designation for measuring current
        transformers
   11.2 Limits of current error and phase displacement
        for measuring current transformers
   11.3 Extended current ratings
   11.4 Type tests for accuracy of measuring current
        transformers
   11.5 Routine tests for accuracy of measuring current
        transformers
   11.6 Instrument security current
   11.7 Marking of the rating plate of a measuring
        current transformer
12 Additional requirements for protective current
   transformers
   12.1 Standard accuracy limit factors
   12.2 Accuracy classes for protective current transformer
   12.3 Limits of errors for protective current transformers
   12.4 Type and routine tests for current error and
        phase displacement of protective current transformers
   12.5 Type tests for composite error
   12.6 Routine tests for composite error
   12.7 Marking of the rating plate of a protective
        current transformer
13 Additional requirements for class PR protective current
   transformers
   13.1 Standard accuracy limit factors
   13.2 Accuracy classes for class PR protective current
        transformers
   13.3 Limits of error for class PR protective current
          transformers
   13.4 Type and routine tests for current error and
        phase displacement of class PR protective current
        transformers
   13.5 Marking of rating plate of class PR current
        transformers
14 Additional requirements for class PX protective current
   transformers
   14.1 Specification of performance for class PX
        protective current transformers
   14.2 Insulation requirements for class PX protective
        current transformers
   14.3 Type tests for class PX protective current
        transformers
   14.4 Routine tests for class PX protective current
        transformers
   14.5 Marking of rating plate of class PX current
        transformers
Annex A (normative) - Protective current transformers
Annex B (informative) - Multiple chopped impulse test

Applies to newly manufactured current transformers for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. Applies basically to transformers with separate windings, but also to autotransformers.

DocumentType
Standard
Pages
220
ProductNote
Reconfirmed EN
PublisherName
Canadian Standards Association
Status
Superseded
SupersededBy
Supersedes

IEC 60695-11-20:2015 Fire hazard testing - Part 11-20: Test flames - 500 W flame test method
IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use
IEC 60038:2009 IEC standard voltages
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60721-1:1990+AMD1:1992+AMD2:1995 CSV Classification of environmental conditions - Part 1: Environmental parameters and their severities
IEC 60028:1925 International standard of resistance for copper
IEC 60721-3-9:1993 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 9: Microclimates inside products
IEC 62155:2003 Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V
IEC TS 61462:1998 Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations
ASTM D 4364 : 2013 : REDLINE Standard Practice for Performing Outdoor Accelerated Weathering Tests of Plastics Using Concentrated Sunlight
IEC 60721-2-7:1987 Classification of environmental conditions. Part 2: Environmental conditions appearing in nature. Fauna and flora
IEC 60599:2015 Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis
IEC 60721-3-7:1995+AMD1:1996 CSV Classification of environmental conditions - Part 3-7: Classification of groups of environmental parameters and their severities - Portable and non-stationary use
IEC 60721-3-5:1997 Classification of environmental conditions - Part 3: Classificationof groups of environmental parameters and their severities -Section 5: Ground vehicle installations
IEC 60721-2-5:1991 Classification of environmental conditions - Part 2: Environmental conditions appearing in nature - Section 5: Dust, sand, salt mist
IEEE C57.13.5-2009 IEEE Standard of Performance and Test Requirements for Instrument Transformers of a Nominal System Voltage of 115 kV and Above
IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment
IEC 60567:2011 Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
IEC 60721-2-1:2013 Classification of environmental conditions - Part 2-1: Environmental conditions appearing in nature - Temperature and humidity
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEC 60721-2-2:2012 Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind
ASTM G 154 : 2016 : REDLINE Standard Practice for Operating Fluorescent Ultraviolet (UV) Lamp Apparatus for Exposure of Nonmetallic Materials
ASTM D 2303 : 2013 Standard Test Methods for Liquid-Contaminant, Inclined-Plane Tracking and Erosion of Insulating Materials
IEC 60721-2-6:1990 Classification of environmental conditions. Part 2: Environmental conditions appearing in nature. Earthquake vibration and shock
IEC 60044-6:1992 Instrument transformers - Part 6: Requirements for protective current transformers for transient performance
IEC 60121:1960 Recommendation for commercial annealed aluminium electrical conductor wire
IEC 60068-2-17:1994 Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing
IEC 60721-3-0:1984+AMD1:1987 CSV Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Introduction
IEC 60721-3-2:1997 Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
IEC 60721-2-8:1994 Classification of environmental conditions - Part 2: Environmental conditions appearing in nature - Section 8: Fire exposure
IEC 60050-321:1986 International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers
IEC TS 60695-11-3:2004 Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
IEC 61181:2007+AMD1:2012 CSV Mineral oil-filled electrical equipment - Application of dissolved gas analysis (DGA) to factory tests on electrical equipment
IEC 60721-2-4:1987+AMD1:1988 CSV Classification of environmental conditions - Part 2-4: Environmental conditions appearing in nature - Solar radiation and temperature
IEC 60587:2007 Electrical insulating materials used under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules
IEC TS 60695-11-4:2004 Fire hazard testing - Part 11-4: Test flames - 50 W flame - Apparatus and confirmational test method
IEC 60721-3-6:1987 Classification of environmental conditions. Part 3: Classification of groups of environmental parameters and their severities. Ship environment
IEEE 693-2005 IEEE Recommended Practice for Seismic Design of Substations
IEC 60721-2-3:2013 Classification of environmental conditions - Part 2-3: Environmental conditions appearing in nature - Air pressure
CSA C1264 : 0 CERAMIC PRESSURIZED HOLLOW INSULATORS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
IEC 60721-3-1:1997 Classification of environmental conditions - Part 3 Classification of groups of environmental parameters and their severities - Section 1: Storage

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.