DIN EN 12101-3:2015-12
Current
The latest, up-to-date edition.
SMOKE AND HEAT CONTROL SYSTEMS - PART 3: SPECIFICATION FOR POWERED SMOKE AND HEAT CONTROL VENTILATORS (FANS)
Hardcopy , PDF
German, English
01-01-2015
National foreword
European foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions, symbols and abbreviations
4 Requirements
5 Testing, assessment and sampling methods
6 Assessment and verification of constancy of
performance - AVCP
7 Marking, labelling and packaging
Annex A (normative) - Criteria to determine family
of fans in order to select the sizes to be tested
Annex B (normative) - Criteria to determine a family
of motors in order to select the sizes to be tested
Annex C (normative) - Test method for the determination
of fire resistance of powered smoke and heat control
ventilators (fans)
Annex D (normative) - Test methods for electric motors
to determine the impact of the changes on the product
characteristics
Annex E (normative) - Test method for assessing the
response delay and ability to open under environmental
conditions
Annex F (informative) - Explanatory notes
Annex G (informative) - General guidance for installation
and maintenance
Annex ZA (informative) - Clauses of this European Standard
addressing the provisions of the EU Construction
Products Regulation
Bibliography
This standard is included in DIN Handbook 300/6.
| DocumentType |
Standard
|
| Pages |
102
|
| PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
| Status |
Current
|
| Standards | Relationship |
| NEN EN 12101-3 : 2015 | Identical |
| NBN EN 12101-3 : 2015 | Identical |
| NS EN 12101-3 : 2002 | Identical |
| I.S. EN 12101-3:2015 | Identical |
| NF EN 12101-3 : 2015 | Identical |
| BS EN 12101-3:2015 | Identical |
| EN 12101-3:2015 | Identical |
| UNE-EN 12101-3:2016 | Identical |
| VDI 3564 Blatt 1:2017-05 | Fire protection - Recommendations for high-bay warehouses |
| VDI 6010 Blatt 2:2011-05 | Technical safety installations - Automation and control of fire protective services |
| VDI 3819 Blatt 2:2013-07 | Fire protection building services - Functions and correlations |
| DIN HDBK 300/6 : 3ED 2017 | BRANDSCHUTZ - BRANDSCHUTZTECHNISCHE PLANUNG UND AUSLEGUNG BEI SONDERBAUTEN |
| ASTM E 228 : 2017 : REDLINE | Standard Test Method for Linear Thermal Expansion of Solid Materials With a Push-Rod Dilatometer |
| EN ISO 6892-1:2016 | Metallic materials - Tensile testing - Part 1: Method of test at room temperature (ISO 6892-1:2016) |
| EN 12101-2:2017 | Smoke and heat control systems - Part 2: Natural smoke and heat exhaust ventilators |
| EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
| EN 60034-1:2010/corrigendum Oct. 2010 | ROTATING ELECTRICAL MACHINES - PART 1: RATING AND PERFORMANCE |
| ISO 6892-1:2016 | Metallic materials — Tensile testing — Part 1: Method of test at room temperature |
| EN 13501-4:2016 | Fire classification of construction products and building elements - Part 4: Classification using data from fire resistance tests on components of smoke control systems |
| ISO 3:1973 | Preferred numbers — Series of preferred numbers |
| EN ISO 204:2009 | Metallic materials - Uniaxial creep testing in tension - Method of test (ISO 204:2009) |
| ISO 281:2007 | Rolling bearings — Dynamic load ratings and rating life |
| EN 60034-18-41:2014 | Rotating electrical machines - Part 18-41: Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters - Qualification and quality control tests |
| ASTM E 1461 : 2013 : REDLINE | Standard Test Method for Thermal Diffusivity by the Flash Method |
| EN ISO 5801:2017 | Fans - Performance testing using standardized airways (ISO 5801:2017) |
| ISO 5801:2017 | Fans — Performance testing using standardized airways |
| IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
| IEC 60034-2-1:2014 | Rotating electrical machines - Part 2-1: Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles) |
| EN ISO 9001:2015 | Quality management systems - Requirements (ISO 9001:2015) |
| IEC TS 60034-17:2006 | Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide |
| IEC 60034-18-41:2014 | Rotating electrical machines - Part 18-41: Partial discharge free electrical insulation systems (Type I) used in rotating electrical machines fed from voltage converters - Qualification and quality control tests |
| EN 60034-2-1:2014 | Rotating electrical machines - Part 2-1: Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles) |
| IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
| EN ISO 6892-2:2011 | Metallic materials - Tensile testing - Part 2: Method of test at elevated temperature (ISO 6892-2:2011) |
| ISO 9001:2015 | Quality management systems — Requirements |
| ISO 14520-1:2015 | Gaseous fire-extinguishing systems — Physical properties and system design — Part 1: General requirements |
| ISO 6892-2:2011 | Metallic materials — Tensile testing — Part 2: Method of test at elevated temperature |
| ISO 1099:2017 | Metallic materials — Fatigue testing — Axial force-controlled method |
| CLC/TS 60034-17:2004 | Rotating electrical machines - Part 17: Cage induction motors when fed from converters - Application guide |
| ISO 834-1:1999 | Fire-resistance tests — Elements of building construction — Part 1: General requirements |
| ISO 204:2009 | Metallic materials — Uniaxial creep testing in tension — Method of test |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.