Generic Specification: Fixed aluminium electrolytic a.c. capacitors with non-solid electrolyte for use with motors
01-07-1997
03-10-1995
Foreword
1 Scope
2 General
2.1 Related Documents
2.2 Units, symbols and terminology
2.3 Preferred values
2.4 Marking
3 QUALITY ASSESSMENT PROCEDURES
3.1 General
3.2 Primary stage of manufacture
3.3 Subcontracting
3.4 Structurally similar components
3.5 Qualification approval procedures
3.6 Capability approval procedures
3.7 Rework and repair work
3.8 Release for delivery
3.9 Certified test records
3.10 Delayed delivery
3.11 Alternative test methods
3.12 Manufacture outside the geographical limits of
CECC supervising
3.13 Intermediate values within an approved range
4 TESTS AND MEASUREMENT PROCEDURES
4.1 General
4.2 Standard atmospheric conditions
4.3 Visual examination and check of dimensions
4.4 Insulation resistance
4.5 Voltage proof, a.c. test
4.6 Capacitance
4.7 Tangent of loss angle
4.8 Variation of capacitance with temperature
4.9 Capacitive leakage current
4.10 Robustness of terminations
4.11 Resistance to soldering heat
4.12 Solderability
4.13 Rapid change of temperature
4.14 Vibration
4.15 Container sealing
4.16 Damp heat, steady state
4.17 Endurance
4.18 Dielectric stability
4.19 Pressure relief
4.20 Solvent resistance of marking
4.21 Electrical contact between metal case and
mounting device
ANNEX A (normative) INTERPRETATION OF SAMPLING PLANS AND
PROCEDURES AS DESCRIBED IN IEC 410 FOR USE WITHIN THE
CECC SYSTEM FOR ELECTRONIC COMPONENTS
This specification is applicable to fixed a.c. aluminium electrolytic capacitors intended:- for connection to windings of asynchronous motors supplied from a single-phase system having a frequency up to and including 100Hz.- to be connected to three-phase asynchronous motors so that the motors may be supplied from a single-phase system.This specification is not applicable to radio interference suppression capacitors, covered by EN 132 400.Neither is it applicable to capacitors for use in electronic equipment, covered by EN 130 000.It establishes standard terms inspection procedures, methods of test for use in sectional and detail specifications within the CECC System, guide-lines for safety rules and for installation and operation.
Committee |
CLC/SR 33
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Withdrawn
|
Standards | Relationship |
NF EN 137000 : 2015 | Identical |
DIN EN 137000 : 1998-03 | Identical |
I.S. EN 137000:1995 | Identical |
SN EN 137000 : 1995 | Identical |
UNE-EN 137000:1995 | Identical |
NEN EN 137000 : 1995 | Identical |
NBN EN 137000 : 2008 | Identical |
BS EN 137000:1996 | Identical |
PN EN 137000 : 2002 | Identical |
VDE 0560-800 : 1998 | Identical |
S.R. CLC/TR 50454:2008 | GUIDE FOR THE APPLICATION OF ALUMINIUM ELECTROLYTIC CAPACITORS |
EN 137100:1995 | Sectional Specification: Fixed aluminium electrolytic a.c. capacitors with non-solid electrolyte for motor starter applications - Qualification approval |
PD CLC/TR 50454:2008 | Guide for the application of aluminium electrolytic capacitors |
CEI CLC/TR 50454 : 2011 | GUIDE FOR THE APPLICATION OF ALUMINIUM ELECTROLYTIC CAPACITORS |
CLC/TR 50454:2008 | Guide for the application of aluminium electrolytic capacitors |
VDE 0560-810 : 1998 | SECTIONAL SPECIFICATION - FIXED ALUMINIUM ELECTROLYTIC A.C. CAPACITORS WITH NON-SOLID ELECTROLYTE FOR MOTOR STARTER APPLICATIONS - QUALIFICATION APPROVAL |
DIN EN 137100 : 1998 | SECTIONAL SPECIFICATION - FIXED ALUMINIUM ELECTROLYTIC A.C. CAPACITORS WITH NON-SOLID ELECTROLYTE FOR MOTOR STARTER APPLICATIONS - QUALIFICATION APPROVAL |
CECC 00114-3 : 94 AMD 2 | CAPABILITY APPROVAL OF AN ELECTRONIC COMPONENT MANUFACTURING ACTIVITY |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 60068-2-20:2008 | Environmental testing - Part 2-20: Tests - Test T: Test methods for solderability and resistance to soldering heat of devices with leads |
IEC 60068-2-21:2006 | Environmental testing - Part 2-21: Tests - Test U: Robustness of terminations and integral mounting devices |
IEC 60068-2-13:1983 | Basic environmental testing procedures - Part 2-13: Tests - Test M: Low air pressure |
IEC 60027-1:1992 | Letters symbols to be used in electrical technology - Part 1: General |
IEC 60410:1973 | Sampling plans and procedures for inspection by attributes |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 60068-2-3:1969 | Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state |
IEC 60294:2012 | Measurement of the dimensions of a cylindrical component with axial terminations |
EN 100114-1 : 1996 | RULE OF PROCEDURE - QUALITY ASSESSMENT PROCEDURES - PART 1: CECC REQUIREMENTS FOR THE APPROVAL OF AN ORGANIZATION |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
CECC 00114-2 : 1994 | RULE OF PROCEDURE 14 - QUALITY ASSESSMENT PROCEDURES - PART 2: QUALIFICATION APPROVAL OF ELECTRONIC COMPONENTS |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 60062:2016 | Marking codes for resistors and capacitors |
IEC 60068-2-2a:1976 | Supplement A - Basic environmental testing procedures - Part 2: Tests - Tests B: Dry heat |
ISO 497:1973 | Guide to the choice of series of preferred numbers and of series containing more rounded values of preferred numbers |
IEC 60068-2-29:1987 | Environmental testing. Part 2: Tests. Test Eb and guidance: Bump |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC 60068-2-14:2009 | Environmental testing - Part 2-14: Tests - Test N: Change of temperature |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-